These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

146 related articles for article (PubMed ID: 26029730)

  • 1. Optimization of energy window and evaluation of scatter compensation methods in myocardial perfusion SPECT using the ideal observer with and without model mismatch and an anthropomorphic model observer.
    Ghaly M; Links JM; Frey E
    J Med Imaging (Bellingham); 2015 Jan; 2(1):. PubMed ID: 26029730
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Collimator optimization and collimator-detector response compensation in myocardial perfusion SPECT using the ideal observer with and without model mismatch and an anthropomorphic model observer.
    Ghaly M; Links JM; Frey EC
    Phys Med Biol; 2016 Mar; 61(5):2109-23. PubMed ID: 26894376
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Optimization of energy window for 90Y bremsstrahlung SPECT imaging for detection tasks using the ideal observer with model-mismatch.
    Rong X; Ghaly M; Frey EC
    Med Phys; 2013 Jun; 40(6):062502. PubMed ID: 23718607
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Assessment of scatter compensation strategies for (67)Ga SPECT using numerical observers and human LROC studies.
    Farncombe TH; Gifford HC; Narayanan MV; Pretorius PH; Frey EC; King MA
    J Nucl Med; 2004 May; 45(5):802-12. PubMed ID: 15136630
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Channelized hotelling and human observer correlation for lesion detection in hepatic SPECT imaging.
    Gifford HC; King MA; de Vries DJ; Soares EJ
    J Nucl Med; 2000 Mar; 41(3):514-21. PubMed ID: 10716327
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Application of task-based measures of image quality to optimization and evaluation of three-dimensional reconstruction-based compensation methods in myocardial perfusion SPECT.
    Frey EC; Gilland KL; Tsui BM
    IEEE Trans Med Imaging; 2002 Sep; 21(9):1040-50. PubMed ID: 12564872
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Optimization and comparison of simultaneous and separate acquisition protocols for dual isotope myocardial perfusion SPECT.
    Ghaly M; Links JM; Frey EC
    Phys Med Biol; 2015 Jul; 60(13):5083-101. PubMed ID: 26083239
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of 180 degrees and 360 degrees acquisition for myocardial perfusion SPECT with compensation for attenuation, detector response, and scatter: Monte Carlo and mathematical observer results.
    He X; Links JM; Gilland KL; Tsui BM; Frey EC
    J Nucl Cardiol; 2006; 13(3):345-53. PubMed ID: 16750779
    [TBL] [Abstract][Full Text] [Related]  

  • 9. An investigation of the trade-off between the count level and image quality in myocardial perfusion SPECT using simulated images: the effects of statistical noise and object variability on defect detectability.
    He X; Links JM; Frey EC
    Phys Med Biol; 2010 Sep; 55(17):4949-61. PubMed ID: 20693615
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Optimum compensation method and filter cutoff frequency in myocardial SPECT: a human observer study.
    Sankaran S; Frey EC; Gilland KL; Tsui BM
    J Nucl Med; 2002 Mar; 43(3):432-8. PubMed ID: 11884505
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Development of 4D mathematical observer models for the task-based evaluation of gated myocardial perfusion SPECT.
    Lee TS; Frey EC; Tsui BM
    Phys Med Biol; 2015 Apr; 60(7):2751-63. PubMed ID: 25768980
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Optimization and evaluation of reconstruction-based compensation methods and reconstruction parameters for Tc-99m MIBI parathyroid SPECT.
    Ekjeen T; Tocharoenchai C; Pusuwan P; Fung GS; Ghaly M; Du Y; Frey EC
    Phys Med; 2015 Mar; 31(2):159-66. PubMed ID: 25555904
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Collimator optimization in myocardial perfusion SPECT using the ideal observer and realistic background variability for lesion detection and joint detection and localization tasks.
    Ghaly M; Du Y; Links JM; Frey EC
    Phys Med Biol; 2016 Mar; 61(5):2048-66. PubMed ID: 26895287
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The Evaluation of Corrective Reconstruction Method For Reduced Acquisition Time and Various Anatomies of Perfusion Defect Using Channelized Hotelling Observer for Myocardial Perfusion SPECT.
    Lee TS; Tsui BM
    IEEE Nucl Sci Symp Conf Rec (1997); 2010; 2010():3523-3526. PubMed ID: 26536462
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A method for energy window optimization for quantitative tasks that includes the effects of model-mismatch on bias: application to Y-90 bremsstrahlung SPECT imaging.
    Rong X; Du Y; Frey EC
    Phys Med Biol; 2012 Jun; 57(12):3711-25. PubMed ID: 22617760
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Body-contour versus circular orbit acquisition in cardiac SPECT: assessment of defect detectability with channelized Hotelling observer.
    Sohlberg A; Watabe H; Shidahara M; Iida H
    Nucl Med Commun; 2007 Dec; 28(12):937-42. PubMed ID: 18090221
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Can patient-specific acquisition protocol improve performance on defect detection task in myocardial perfusion SPECT?
    Choi NR; Rahman MA; Yu Z; Siegel BA; Jha AK
    ArXiv; 2024 Mar; ():. PubMed ID: 38584618
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Task-based evaluation of a 4D MAP-RBI-EM image reconstruction method for gated myocardial perfusion SPECT using a human observer study.
    Lee TS; Higuchi T; Lautamäki R; Bengel FM; Tsui BM
    Phys Med Biol; 2015 Sep; 60(17):6789-809. PubMed ID: 26301337
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Application of reconstruction-based scatter compensation to thallium-201 SPECT: implementations for reduced reconstructed image noise.
    Kadrmas DJ; Frey EC; Tsui BM
    IEEE Trans Med Imaging; 1998 Jun; 17(3):325-33. PubMed ID: 9735896
    [TBL] [Abstract][Full Text] [Related]  

  • 20. An SVD Investigation of Modeling Scatter in Multiple Energy Windows for Improved SPECT Images.
    Kadrmas DJ; Frey EC; Tsui BM
    IEEE Trans Nucl Sci; 1996 Aug; 43(3):2275-2284. PubMed ID: 20186285
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.