These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

143 related articles for article (PubMed ID: 2603089)

  • 21. [Orthodontic studies on super-elastic NiTi alloy wire. 2. Bending and controlling the amount of force].
    Ohura Y
    Nihon Kyosei Shika Gakkai Zasshi; 1988 Mar; 47(1):92-104. PubMed ID: 3253373
    [No Abstract]   [Full Text] [Related]  

  • 22. Influence of autoclave sterilization on the surface parameters and mechanical properties of six orthodontic wires.
    Pernier C; Grosgogeat B; Ponsonnet L; Benay G; Lissac M
    Eur J Orthod; 2005 Feb; 27(1):72-81. PubMed ID: 15743866
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Effect of heat treatment conditions on the mechanical properties of Ti-6Mo-4Sn alloy for orthodontic wires.
    Hida M; Miyazawa K; Tsuruta S; Kurosawa M; Hata Y; Kawai T; Goto S
    Dent Mater J; 2013; 32(3):462-7. PubMed ID: 23719009
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Force-deflection properties of initial orthodontic archwires.
    Quintão CC; Cal-Neto JP; Menezes LM; Elias CN
    World J Orthod; 2009; 10(1):29-32. PubMed ID: 19388430
    [TBL] [Abstract][Full Text] [Related]  

  • 25. An evaluation of the shape-memory phenomenon of nickel-titanium orthodontic wires.
    Hurst CL; Duncanson MG; Nanda RS; Angolkar PV
    Am J Orthod Dentofacial Orthop; 1990 Jul; 98(1):72-6. PubMed ID: 2363408
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Thermomechanical study of Ni-Ti alloys.
    Lee JH; Park JB; Andreasen GF; Lakes RS
    J Biomed Mater Res; 1988 Jun; 22(6):573-88. PubMed ID: 3410873
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Evolution of flexural rigidity according to the cross-sectional dimension of a superelastic nickel titanium orthodontic wire.
    Garrec P; Tavernier B; Jordan L
    Eur J Orthod; 2005 Aug; 27(4):402-7. PubMed ID: 16043477
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Super-elastic property of Ti-Ni alloy for use in dentistry.
    Yoneyama T; Doi H; Kobayashi E; Hamanaka H
    Front Med Biol Eng; 2000; 10(2):97-103. PubMed ID: 10898239
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Comparison of frictional resistance after immersion of metal brackets and orthodontic wires in a fluoride-containing prophylactic agent.
    Kao CT; Ding SJ; Wang CK; He H; Chou MY; Huang TH
    Am J Orthod Dentofacial Orthop; 2006 Nov; 130(5):568.e1-9. PubMed ID: 17110251
    [TBL] [Abstract][Full Text] [Related]  

  • 30. In-vitro evaluation of the material characteristics of stainless steel and beta-titanium orthodontic wires.
    Verstrynge A; Van Humbeeck J; Willems G
    Am J Orthod Dentofacial Orthop; 2006 Oct; 130(4):460-70. PubMed ID: 17045145
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Variation of the superelastic properties and nickel release from original and reused NiTi orthodontic archwires.
    Gil FJ; Espinar E; Llamas JM; Manero JM; Ginebra MP
    J Mech Behav Biomed Mater; 2012 Feb; 6():113-9. PubMed ID: 22301180
    [TBL] [Abstract][Full Text] [Related]  

  • 32. [New ultra-elastic Ni-Ti orthodontic wire].
    Hamanaka H; Watanabe K; Miura I
    DE J Dent Eng; 1982; (60):28-33. PubMed ID: 6804183
    [No Abstract]   [Full Text] [Related]  

  • 33. [Super-elastic wire used in orthodontics].
    Laino A; Boscaino F; Michelotti A
    Mondo Ortod; 1990; 15(6):707-14. PubMed ID: 2074888
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Comparisons of the thermodynamic properties of three nickel-titanium orthodontic archwires.
    Bishara SE; Winterbottom JM; Sulieman AH; Rim K; Jakobsen JR
    Angle Orthod; 1995; 65(2):117-22. PubMed ID: 7785802
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Mechanical properties of several nickel-titanium alloy wires in three-point bending tests.
    Nakano H; Satoh K; Norris R; Jin T; Kamegai T; Ishikawa F; Katsura H
    Am J Orthod Dentofacial Orthop; 1999 Apr; 115(4):390-5. PubMed ID: 10194282
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Transformation behavior, chemical composition, surface topography and bending properties of five selected 0.016" x 0.022" NiTi archwires.
    Fischer-Brandies H; Es-Souni M; Kock N; Raetzke K; Bock O
    J Orofac Orthop; 2003 Mar; 64(2):88-99. PubMed ID: 12649705
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Structure and thermomechanical behavior of NiTiPt shape memory alloy wires.
    Lin B; Gall K; Maier HJ; Waldron R
    Acta Biomater; 2009 Jan; 5(1):257-67. PubMed ID: 18718825
    [TBL] [Abstract][Full Text] [Related]  

  • 38. On the variability of cross-sectional dimensions and torsional properties of rectangular nickel-titanium arch wires.
    Meling TR; Odegaard J
    Am J Orthod Dentofacial Orthop; 1998 May; 113(5):546-57. PubMed ID: 9598613
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Load-deflection characteristics of nickel-titanium alloy wires after clinical recycling and dry heat sterilization.
    Kapila S; Haugen JW; Watanabe LG
    Am J Orthod Dentofacial Orthop; 1992 Aug; 102(2):120-6. PubMed ID: 1636628
    [TBL] [Abstract][Full Text] [Related]  

  • 40. The super-elastic property of the Japanese NiTi alloy wire for use in orthodontics.
    Miura F; Mogi M; Ohura Y; Hamanaka H
    Am J Orthod Dentofacial Orthop; 1986 Jul; 90(1):1-10. PubMed ID: 3460342
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.