These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

297 related articles for article (PubMed ID: 26031361)

  • 1. Inter-rater reliability and validity of automated impedance manometry analysis and fluoroscopy in dysphagic patients after head and neck cancer radiotherapy.
    Szczesniak MM; Maclean J; Zhang T; Liu R; Cock C; Rommel N; Omari TI; Cook IJ
    Neurogastroenterol Motil; 2015 Aug; 27(8):1183-9. PubMed ID: 26031361
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Reproducibility and agreement of pharyngeal automated impedance manometry with videofluoroscopy.
    Omari TI; Papathanasopoulos A; Dejaeger E; Wauters L; Scarpellini E; Vos R; Slootmaekers S; Seghers V; Cornelissen L; Goeleven A; Tack J; Rommel N
    Clin Gastroenterol Hepatol; 2011 Oct; 9(10):862-7. PubMed ID: 21699810
    [TBL] [Abstract][Full Text] [Related]  

  • 3. An impedance-manometry based method for non-radiological detection of pharyngeal postswallow residue.
    Omari TI; Dejaeger E; Tack J; Vanbeckevoort D; Rommel N
    Neurogastroenterol Motil; 2012 Jul; 24(7):e277-84. PubMed ID: 22594606
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A novel method for the nonradiological assessment of ineffective swallowing.
    Omari TI; Dejaeger E; Van Beckevoort D; Goeleven A; De Cock P; Hoffman I; Smet MH; Davidson GP; Tack J; Rommel N
    Am J Gastroenterol; 2011 Oct; 106(10):1796-802. PubMed ID: 21556039
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A method to objectively assess swallow function in adults with suspected aspiration.
    Omari TI; Dejaeger E; van Beckevoort D; Goeleven A; Davidson GP; Dent J; Tack J; Rommel N
    Gastroenterology; 2011 May; 140(5):1454-63. PubMed ID: 21354152
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Objective assessment of swallow function in children with suspected aspiration using pharyngeal automated impedance manometry.
    Rommel N; Selleslagh M; Hoffman I; Smet MH; Davidson G; Tack J; Omari TI
    J Pediatr Gastroenterol Nutr; 2014 Jun; 58(6):789-94. PubMed ID: 24552674
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Swallowing dysfunction in healthy older people using pharyngeal pressure-flow analysis.
    Omari TI; Kritas S; Cock C; Besanko L; Burgstad C; Thompson A; Rommel N; Heddle R; Fraser RJ
    Neurogastroenterol Motil; 2014 Jan; 26(1):59-68. PubMed ID: 24011430
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Intraluminal impedance detects failure of pharyngeal bolus clearance during swallowing: a validation study in adults with dysphagia.
    Szczesniak MM; Rommel N; Dinning PG; Fuentealba SE; Cook IJ; Omari TI
    Neurogastroenterol Motil; 2009 Mar; 21(3):244-52. PubMed ID: 18761629
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effect of bolus volume and viscosity on pharyngeal automated impedance manometry variables derived for broad Dysphagia patients.
    Omari TI; Dejaeger E; Tack J; Van Beckevoort D; Rommel N
    Dysphagia; 2013 Jun; 28(2):146-52. PubMed ID: 22986957
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Inter- and intra-rater reproducibility of automated and integrated pressure-flow analysis of esophageal pressure-impedance recordings.
    Rohof WO; Myers JC; Estremera FA; Ferris LS; van de Pol J; Boeckxstaens GE; Omari TI
    Neurogastroenterol Motil; 2014 Feb; 26(2):168-75. PubMed ID: 24164976
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Fibreoptic endoscopic evaluation of swallowing and videofluoroscopy: does examination type influence perception of pharyngeal residue severity?
    Kelly AM; Leslie P; Beale T; Payten C; Drinnan MJ
    Clin Otolaryngol; 2006 Oct; 31(5):425-32. PubMed ID: 17014453
    [TBL] [Abstract][Full Text] [Related]  

  • 12. High-resolution impedance manometry facilitates assessment of pharyngeal residue and oropharyngeal dysphagic mechanisms.
    Lee TH; Lee JS; Park JW; Cho SJ; Hong SJ; Jeon SR; Kim WJ; Kim HG; Cho JY; Kim JO
    Dis Esophagus; 2014 Apr; 27(3):220-9. PubMed ID: 23855892
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Within-Bolus Variability of the Penetration-Aspiration Scale Across Two Subsequent Swallows in Patients with Head and Neck Cancer.
    Hedström J; Tuomi L; Andersson M; Dotevall H; Osbeck H; Finizia C
    Dysphagia; 2017 Oct; 32(5):683-690. PubMed ID: 28593510
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Upper esophageal sphincter impedance as a marker of sphincter opening diameter.
    Omari TI; Ferris L; Dejaeger E; Tack J; Vanbeckevoort D; Rommel N
    Am J Physiol Gastrointest Liver Physiol; 2012 May; 302(9):G909-13. PubMed ID: 22323128
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Inter- and intra-rater reliability of cervical auscultation to detect aspiration in patients with dysphagia.
    Stroud AE; Lawrie BW; Wiles CM
    Clin Rehabil; 2002 Sep; 16(6):640-5. PubMed ID: 12392339
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Interrater reliability of videofluoroscopic swallow evaluation.
    Stoeckli SJ; Huisman TA; Seifert B; Martin-Harris BJ
    Dysphagia; 2003; 18(1):53-7. PubMed ID: 12497197
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Diagnosis of Swallowing Disorders: How We Interpret Pharyngeal Manometry.
    Cock C; Omari T
    Curr Gastroenterol Rep; 2017 Mar; 19(3):11. PubMed ID: 28289859
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Relationship between manometric and videofluoroscopic measures of swallow function in healthy adults and patients treated for head and neck cancer with various modalities.
    Pauloski BR; Rademaker AW; Lazarus C; Boeckxstaens G; Kahrilas PJ; Logemann JA
    Dysphagia; 2009 Jun; 24(2):196-203. PubMed ID: 18956228
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Objective prediction of pharyngeal swallow dysfunction in dysphagia through artificial neural network modeling.
    Kritas S; Dejaeger E; Tack J; Omari T; Rommel N
    Neurogastroenterol Motil; 2016 Mar; 28(3):336-44. PubMed ID: 26891061
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Videofluoroscopic Swallow Examination Does Not Accurately Detect Cricopharyngeal Radiation Strictures.
    Szczesniak MM; Maclean J; O'Hare J; Humbert I; Wu PI; Quon H; Graham PH; Cook IJ
    Otolaryngol Head Neck Surg; 2016 Sep; 155(3):462-5. PubMed ID: 27143709
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 15.