These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

80 related articles for article (PubMed ID: 2603566)

  • 1. [A transistor-based portable electroplethysmograph].
    Manukian GKh
    Zh Vyssh Nerv Deiat Im I P Pavlova; 1989; 39(5):971-3. PubMed ID: 2603566
    [No Abstract]   [Full Text] [Related]  

  • 2. [4-channel transistor attachment for recording tissue blood flow by hydrogen clearance].
    Brill' GE; Dovbush VA; Sergeev IP
    Patol Fiziol Eksp Ter; 1983; (5):83-5. PubMed ID: 6646840
    [No Abstract]   [Full Text] [Related]  

  • 3. Cardiac output by electrical impedance.
    Sramek BB
    Med Electron; 1982 Apr; 13(2):93-7. PubMed ID: 10257596
    [No Abstract]   [Full Text] [Related]  

  • 4. A defense of electrical impedance plethysmography. Comments on a paper Electrical impedance plethysmography: a critical analysis.
    Kinnen E; Hill RV; Jansen JC
    Med Res Eng; 1969; 8(4):6-9. PubMed ID: 5823263
    [No Abstract]   [Full Text] [Related]  

  • 5. [Device for the power supply of the 4RG-1 rheographic attachment].
    Gudkov AI; Frolov AV
    Voen Med Zh; 1979 Aug; (8):70-1. PubMed ID: 516515
    [No Abstract]   [Full Text] [Related]  

  • 6. [Devices for the synchronization of digital measuring apparatus by biological signals].
    Sokoliuk AM
    Fiziol Zh (1978); 1979; 25(1):93-5. PubMed ID: 421938
    [No Abstract]   [Full Text] [Related]  

  • 7. Four-channel electronic integrator.
    Bershadskii IG
    Biomed Eng (NY); 1971; 5(1):59-60. PubMed ID: 5136147
    [No Abstract]   [Full Text] [Related]  

  • 8. [Infralow-frequency generators of saw-like tension for the medical equipment].
    Agizim GM; Sherman AM
    Nov Med Tekh; 1975; (4):70-5. PubMed ID: 1235575
    [No Abstract]   [Full Text] [Related]  

  • 9. [Modernization of the RG4-01 rheograph].
    Smirnov VM; Lychkova AE; Lychkov AA
    Fiziol Zh SSSR Im I M Sechenova; 1984 Feb; 70(2):261-3. PubMed ID: 6714478
    [No Abstract]   [Full Text] [Related]  

  • 10. Simple design for an impedence plethysmograph.
    Swanson DK; Webster JG
    Med Biol Eng Comput; 1982 Jul; 20(4):461-5. PubMed ID: 7132451
    [No Abstract]   [Full Text] [Related]  

  • 11. Instrumentation--characteristics of a light emitting diode--transistor photoplethysmograph.
    Tahmoush AJ; Jennings JR; Lee AL; Camp S; Weber F
    Psychophysiology; 1976 Jul; 13(4):357-62. PubMed ID: 951479
    [No Abstract]   [Full Text] [Related]  

  • 12. [Electroplethysmograph for study of the regional functioning of the lungs].
    Mazhbich BI; Kalinin PF
    Med Tekh; 1975; (3):53-6. PubMed ID: 1152658
    [No Abstract]   [Full Text] [Related]  

  • 13. [RG2-01 rheography].
    Polishuk VI
    Med Tekh; 1972; 5():51-2. PubMed ID: 4663469
    [No Abstract]   [Full Text] [Related]  

  • 14. [A portable integrator of bioelectrical signals].
    Divert VE
    Fiziol Zh SSSR Im I M Sechenova; 1984 Dec; 70(12):1694-6. PubMed ID: 6519305
    [No Abstract]   [Full Text] [Related]  

  • 15. [Operational power amplifier for multichannel medical recorders].
    SharshevskiÄ­ BN; Panov VN; Gomberg MS
    Nov Med Tekh; 1977; (4):59-62. PubMed ID: 616912
    [No Abstract]   [Full Text] [Related]  

  • 16. Calibration of dZ/dt in impedance plethysmography.
    Jindal GD; Babu JP
    Med Biol Eng Comput; 1985 May; 23(3):279-80. PubMed ID: 4021573
    [No Abstract]   [Full Text] [Related]  

  • 17. A portable bio-impedance system for monitoring lung resistivity.
    Zlochiver S; Arad M; Radai MM; Barak-Shinar D; Krief H; Engelman T; Ben-Yehuda R; Adunsky A; Abboud S
    Med Eng Phys; 2007 Jan; 29(1):93-100. PubMed ID: 16546432
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [The early diagnosis of hypoglycemic states with an automatic electronic system].
    Zhukov SA; Ivanov VI; D'iakonova NA
    Voen Med Zh; 1993 Jun; (6):62-3. PubMed ID: 8367956
    [No Abstract]   [Full Text] [Related]  

  • 19. Errors in four-electrode impedance plethysmography.
    Swanson DK; Webster JG
    Med Biol Eng Comput; 1983 Nov; 21(6):674-80. PubMed ID: 6664128
    [No Abstract]   [Full Text] [Related]  

  • 20. Impedance cyclography. A new method for accommodation recording.
    Swegmark G; Olsson T
    Acta Ophthalmol (Copenh); 1968; 46(5):946-68. PubMed ID: 5755788
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 4.