These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

526 related articles for article (PubMed ID: 26035818)

  • 1. Intravascular ultrasound observation of the mechanism of no-reflow phenomenon in acute myocardial infarction.
    Li J; Wu L; Tian X; Zhang J; Shi Y
    PLoS One; 2015; 10(6):e0119223. PubMed ID: 26035818
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The relationship between attenuated plaque identified by intravascular ultrasound and no-reflow after stenting in acute myocardial infarction: the HORIZONS-AMI (Harmonizing Outcomes With Revascularization and Stents in Acute Myocardial Infarction) trial.
    Wu X; Mintz GS; Xu K; Lansky AJ; Witzenbichler B; Guagliumi G; Brodie B; Kellett MA; Dressler O; Parise H; Mehran R; Stone GW; Maehara A
    JACC Cardiovasc Interv; 2011 May; 4(5):495-502. PubMed ID: 21596321
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Predictors of no-reflow after percutaneous coronary intervention for culprit lesion with plaque rupture in infarct-related artery in patients with acute myocardial infarction.
    Hong YJ; Jeong MH; Choi YH; Ko JS; Lee MG; Kang WY; Lee SE; Kim SH; Park KH; Sim DS; Yoon NS; Youn HJ; Kim KH; Park HW; Kim JH; Ahn Y; Cho JG; Park JC; Kang JC
    J Cardiol; 2009 Aug; 54(1):36-44. PubMed ID: 19632518
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Impact of ultrasound attenuation and plaque rupture as detected by intravascular ultrasound on the incidence of no-reflow phenomenon after percutaneous coronary intervention in ST-segment elevation myocardial infarction.
    Endo M; Hibi K; Shimizu T; Komura N; Kusama I; Otsuka F; Mitsuhashi T; Iwahashi N; Okuda J; Tsukahara K; Kosuge M; Ebina T; Umemura S; Kimura K
    JACC Cardiovasc Interv; 2010 May; 3(5):540-9. PubMed ID: 20488411
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Relation of atherothrombosis burden and volume detected by intravascular ultrasound to angiographic no-reflow phenomenon during stent implantation in patients with acute myocardial infarction.
    Katayama T; Kubo N; Takagi Y; Funayama H; Ikeda N; Ishida T; Hirahara T; Sugawara Y; Yasu T; Kawakami M; Saito M
    Am J Cardiol; 2006 Feb; 97(3):301-4. PubMed ID: 16442385
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Morphological predictors for no reflow phenomenon after primary percutaneous coronary intervention in patients with ST-segment elevation myocardial infarction caused by plaque rupture.
    Soeda T; Higuma T; Abe N; Yamada M; Yokoyama H; Shibutani S; Ong DS; Vergallo R; Minami Y; Lee H; Okumura K; Jang IK
    Eur Heart J Cardiovasc Imaging; 2017 Jan; 18(1):103-110. PubMed ID: 26800769
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Plaque Composition and No-Reflow Phenomenon During Percutaneous Coronary Intervention of Low-Echoic Structures in Grayscale Intravascular Ultrasound.
    Amano H; Ikeda T; Toda M; Okubo R; Yabe T; Watanabe I; Saito D
    Int Heart J; 2016 May; 57(3):285-91. PubMed ID: 27170472
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Intravascular ultrasound findings that are predictive of no reflow after percutaneous coronary intervention for saphenous vein graft disease.
    Hong YJ; Jeong MH; Ahn Y; Kang JC; Mintz GS; Kim SW; Lee SY; Kim SY; Pichard AD; Satler LF; Waksman R; Weissman NJ
    Am J Cardiol; 2012 Jun; 109(11):1576-81. PubMed ID: 22440118
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Impact of attenuated plaque as detected by intravascular ultrasound on the occurrence of microvascular obstruction after percutaneous coronary intervention in patients with ST-segment elevation myocardial infarction.
    Shiono Y; Kubo T; Tanaka A; Tanimoto T; Ota S; Ino Y; Aoki H; Ozaki Y; Orii M; Shimamura K; Ishibashi K; Yamano T; Yamaguchi T; Hirata K; Imanishi T; Akasaka T
    JACC Cardiovasc Interv; 2013 Aug; 6(8):847-53. PubMed ID: 23871509
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Predictive performance of dual modality of computed tomography angiography and intravascular ultrasound for no-reflow phenomenon after percutaneous coronary stenting in stable coronary artery disease.
    Okutsu M; Horio T; Tanaka H; Akiyama M; Okimoto N; Tsubouchi T; Kawajiri K; Ohashi Y; Sumitsuji S; Ikari Y
    Heart Vessels; 2018 Oct; 33(10):1121-1128. PubMed ID: 29644449
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The decrease of plaque volume during percutaneous coronary intervention has a negative impact on coronary flow in acute myocardial infarction: a major role of percutaneous coronary intervention-induced embolization.
    Sato H; Iida H; Tanaka A; Tanaka H; Shimodouzono S; Uchida E; Kawarabayashi T; Yoshikawa J
    J Am Coll Cardiol; 2004 Jul; 44(2):300-4. PubMed ID: 15261922
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Impact of plaque components on no-reflow phenomenon after stent deployment in patients with acute coronary syndrome: a virtual histology-intravascular ultrasound analysis.
    Hong YJ; Jeong MH; Choi YH; Ko JS; Lee MG; Kang WY; Lee SE; Kim SH; Park KH; Sim DS; Yoon NS; Youn HJ; Kim KH; Park HW; Kim JH; Ahn Y; Cho JG; Park JC; Kang JC
    Eur Heart J; 2011 Aug; 32(16):2059-66. PubMed ID: 19228713
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Predictive value of admission red cell distribution width-platelet ratio for no-reflow phenomenon in acute ST segment elevation myocardial infarction undergoing primary percutaneous coronary intervention.
    Celık T; Balta S; Demır M; Yıldırım AO; Kaya MG; Ozturk C; Demırkol S; Unlu M; Kılıc S; Aydın İ; Iyısoy A
    Cardiol J; 2016; 23(1):84-92. PubMed ID: 26503078
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Risk of no-reflow in culprit lesion versus culprit vessel PCI in acute STEMI.
    Arslan U; Yaman M; Kocaoğlu İ; Turan OE; Yücel H; Aksakal A; Günaydin İA; Hakan Ateş A
    Coron Artery Dis; 2015 Sep; 26(6):510-5. PubMed ID: 26086864
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Relation of stent overexpansion to the angiographic no-reflow phenomenon in intravascular ultrasound-guided stent implantation for acute myocardial infarction.
    Maekawa Y; Asakura Y; Anzai T; Ishikawa S; Okabe T; Yoshikawa T; Ogawa S
    Heart Vessels; 2005 Feb; 20(1):13-8. PubMed ID: 15700197
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A simple and rapid method for identification of lesions at high risk for the no-reflow phenomenon immediately before elective coronary stent implantation.
    Suda A; Namiuchi S; Kawaguchi T; Nihei T; Takii T; Saji K; Sugie T; Kato A; Shimokawa H
    Heart Vessels; 2016 Dec; 31(12):1904-1914. PubMed ID: 26936449
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Plaque shift and distal embolism in patients with acute myocardial infarction: a volumetric intravascular ultrasound analysis from the HORIZONS-AMI trial.
    Wu X; Maehara A; He Y; Xu K; Oviedo C; Witzenbichler B; Lansky AJ; Dressler O; Parise H; Stone GW; Mintz GS
    Catheter Cardiovasc Interv; 2013 Aug; 82(2):203-9. PubMed ID: 22936619
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Angiographic no-reflow phenomenon and plaque characteristics by virtual histology intravascular ultrasound in patients with acute myocardial infarction.
    Nakamura T; Kubo N; Ako J; Momomura S
    J Interv Cardiol; 2007 Oct; 20(5):335-9. PubMed ID: 17880329
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Plaque characteristics and serum pregnancy-associated plasma protein A levels predict the no-reflow phenomenon after percutaneous coronary intervention.
    Zhao XY; Wang XF; Li L; Zhang JY; Du YY; Yao HM
    J Int Med Res; 2013 Apr; 41(2):307-16. PubMed ID: 23569011
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The impact of initial and residual thrombus burden on the no-reflow phenomenon in patients with ST-segment elevation myocardial infarction.
    Ahn SG; Choi HH; Lee JH; Lee JW; Youn YJ; Yoo SY; Cho BR; Lee SH; Yoon J
    Coron Artery Dis; 2015 May; 26(3):245-53. PubMed ID: 25503419
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 27.