  • 1. Risk Factor Analysis of Bird Beak Occurrence after Thoracic Endovascular Aortic Repair.
    Boufi M; Guivier-Curien C; Deplano V; Boiron O; Loundou AD; Dona B; Hartung O; Alimi YS
    Eur J Vasc Endovasc Surg; 2015 Jul; 50(1):37-43. PubMed ID: 26036810
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The impact of bird-beak configuration on aortic remodeling of distal arch pathology after thoracic endovascular aortic repair with the Zenith Pro-Form TX2 thoracic endograft.
    Hsu HL; Chen CK; Chen PL; Chen IM; Hsu CP; Chen CW; Shih CC
    J Vasc Surg; 2014 Jan; 59(1):80-8. PubMed ID: 24139983
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Long-Term Outcomes of Thoracic Endovascular Aortic Repair Focused on Bird Beak and Oversizing in Blunt Traumatic Thoracic Aortic Injury.
    García Reyes ME; Gonçalves Martins G; Fernández Valenzuela V; Domínguez González JM; Maeso Lebrun J; Bellmunt Montoya S
    Ann Vasc Surg; 2018 Jul; 50():140-147. PubMed ID: 29455010
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Risk Factor Analysis for the Mal-Positioning of Thoracic Aortic Stent Grafts.
    Boufi M; Guivier-Curien C; Dona B; Loundou AD; Deplano V; Boiron O; Hartung O; Alimi YS
    Eur J Vasc Endovasc Surg; 2016 Jul; 52(1):56-63. PubMed ID: 27095427
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Association between aortic arch angulation and bird-beak configuration after thoracic aortic stent graft repair of type B aortic dissection.
    Cao L; Ge Y; He Y; Wang X; Rong D; Lu W; Liu X; Guo W
    Interact Cardiovasc Thorac Surg; 2020 Nov; 31(5):688-696. PubMed ID: 33025008
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Proximal Bare Stent May Reduce Bird-Beak Configuration, Which is Associated with Distal Migration of Stent Graft in the Aortic Arch.
    Banno H; Akita N; Fujii T; Tsuruoka T; Takahashi N; Sugimoto M; Niimi K; Komori K
    Ann Vasc Surg; 2019 Apr; 56():108-113. PubMed ID: 30342207
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Examination of factors in type I endoleak development after thoracic endovascular repair.
    Boufi M; Aouini F; Guivier-Curien C; Dona B; Loundou AD; Deplano V; Alimi YS
    J Vasc Surg; 2015 Feb; 61(2):317-23. PubMed ID: 25238727
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Thoracic aortic geometry correlates with endograft bird-beaking severity.
    Frohlich MM; Suh GY; Bondesson J; Leineweber M; Lee JT; Dake MD; Cheng CP
    J Vasc Surg; 2020 Oct; 72(4):1196-1205. PubMed ID: 32035770
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Improvement in conformability of the latest generation of thoracic stent grafts.
    Canaud L; Cathala P; Joyeux F; Branchereau P; Marty-Ané C; Alric P
    J Vasc Surg; 2013 Apr; 57(4):1084-9. PubMed ID: 23332239
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Aortic morphometry at endograft position as assessed by 3D image analysis affects risk of type I endoleak formation after TEVAR.
    Kotelis D; Brenke C; Wörz S; Rengier F; Rohr K; Kauczor HU; Böckler D; von Tengg-Kobligk H
    Langenbecks Arch Surg; 2015 May; 400(4):523-9. PubMed ID: 25702140
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Aortic hemodynamics after thoracic endovascular aortic repair, with particular attention to the bird-beak configuration.
    van Bogerijen GH; Auricchio F; Conti M; Lefieux A; Reali A; Veneziani A; Tolenaar JL; Moll FL; Rampoldi V; Trimarchi S
    J Endovasc Ther; 2014 Dec; 21(6):791-802. PubMed ID: 25453880
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Type 1a endoleak following Zone 1 and Zone 2 thoracic endovascular aortic repair: effect of bird-beak configuration.
    Kudo T; Kuratani T; Shimamura K; Sakamoto T; Kin K; Masada K; Shijo T; Torikai K; Maeda K; Sawa Y
    Eur J Cardiothorac Surg; 2017 Oct; 52(4):718-724. PubMed ID: 29156021
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Incomplete endograft apposition to the aortic arch: bird-beak configuration increases risk of endoleak formation after thoracic endovascular aortic repair.
    Ueda T; Fleischmann D; Dake MD; Rubin GD; Sze DY
    Radiology; 2010 May; 255(2):645-52. PubMed ID: 20413775
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Identification of geometric and mechanical factors predictive of bird-beak configuration in thoracic endovascular aortic repair using computational models of stent graft deployment.
    Shahbazian N; Romero DA; Forbes TL; Amon CH
    JVS Vasc Sci; 2022; 3():259-273. PubMed ID: 35938091
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Anatomic features of the distal aortic arch that influence endovascular aneurysm repair.
    Sweet MP
    J Vasc Surg; 2016 Oct; 64(4):891-5. PubMed ID: 27189767
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Initial clinical experience with the modified Zenith "Pro-Form" TX2 thoracic endograft.
    Melissano G; Civilini E; Bertoglio L; Logaldo D; Chiesa R
    J Endovasc Ther; 2010 Aug; 17(4):463-70. PubMed ID: 20681760
    [TBL] [Abstract][Full Text] [Related]  

  • 17. An In Vitro Phantom Study on the Role of the Bird-Beak Configuration in Endograft Infolding in the Aortic Arch.
    Pasta S; Scardulla F; Rinaudo A; Raffa GM; D'Ancona G; Pilato M; Scardulla C
    J Endovasc Ther; 2016 Feb; 23(1):172-81. PubMed ID: 26496956
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Impact on early outcome after endovascular repair of type B dissection without proximal landing zone using Castor single-branched stent graft-a retrospective cohort study.
    Cheng Z; Zhang H; Pu J; Schoenhagen P; Zhao L; Qiao H; Yang B; Wu W; Zhang C; Wang R; Liu Y; Ma X
    Cardiovasc Diagn Ther; 2024 Feb; 14(1):18-28. PubMed ID: 38434554
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Prediction of bird-beak configuration in thoracic endovascular aortic repair preoperatively using patient-specific finite element simulations.
    Shahbazian N; Romero DA; Forbes TL; Amon CH
    JVS Vasc Sci; 2023; 4():100108. PubMed ID: 37519336
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Midterm results of endovascular stent grafts in the proximal aortic arch (zone 0): an imaging perspective.
    Appoo JJ; Herget EJ; Pozeg ZI; Ferris MC; Wong JK; Gregory AJ; Gupta AK; Merchant N; Kent WD
    Can J Cardiol; 2015 Jun; 31(6):731-7. PubMed ID: 25882336
    [TBL] [Abstract][Full Text] [Related]  