These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

103 related articles for article (PubMed ID: 2604062)

  • 1. Blood collection by evacuated tubes: the effects of the order of filling tubes on the serum values of potassium and lactate dehydrogenase.
    Alegre B; Miralles A; Martinez C; Otte A; Calero G
    Ann Biol Clin (Paris); 1989; 47(8):507. PubMed ID: 2604062
    [No Abstract]   [Full Text] [Related]  

  • 2. Studies on the use of BD Vacutainer® SST II™ and RST™ in general practice: investigation of artefactual hyperkalaemia.
    Huyghe T; Buntinx F; Bruyninckx R; Besard V; Vunckx J; Church S; Byron K; Rosa R; Blanckaert N
    Ann Clin Biochem; 2014 Jan; 51(Pt 1):30-7. PubMed ID: 23897107
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Pneumatic transport is critical for leukaemic patients with major leukocytosis: what precautions to measure lactate dehydrogenase, potassium and aspartate aminotransferase?
    Guiheneuf R; Vuillaume I; Mangalaboyi J; Launay D; Berthon C; Maury JC; Maboudou P; Rousseaux J
    Ann Clin Biochem; 2010 Jan; 47(Pt 1):94-6. PubMed ID: 19940199
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Effect of transport and storage on the composition of blood samples collected for analysis].
    Markelov IM; Puzyrevskiĭ AK; Zhuravlev IuN
    Lab Delo; 1974; 7(9):424-6. PubMed ID: 4139345
    [No Abstract]   [Full Text] [Related]  

  • 5. Insufficient filling of vacuum tubes as a cause of microhemolysis and elevated serum lactate dehydrogenase levels. Use of a data-mining technique in evaluation of questionable laboratory test results.
    Tamechika Y; Iwatani Y; Tohyama K; Ichihara K
    Clin Chem Lab Med; 2006; 44(5):657-61. PubMed ID: 16681441
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Experimental basis of standardized specimen collection: the effect of short moderate exercise on serum K, Na, ASAT, ALAT, CK and LD.
    Leppänen EA
    Scand J Clin Lab Invest; 1989 May; 49(3):287-92. PubMed ID: 2740822
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of plastic vs. glass evacuated serum-separator (SST) blood-drawing tubes for common clinical chemistry determinations.
    Hill BM; Laessig RH; Koch DD; Hassemer DJ
    Clin Chem; 1992 Aug; 38(8 Pt 1):1474-8. PubMed ID: 1643717
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [The reliability of serum potassium levels measured in blood from a central venous catheter].
    Nielsen HK; Svanegaard J; Madsen HH
    Ugeskr Laeger; 1992 Apr; 154(15):1033-5. PubMed ID: 1566513
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Differences between values for plasma and serum in tests performed in the Ektachem 700 XR Analyzer, and evaluation of "plasma separator tubes (PST)".
    Doumas BT; Hause LL; Simuncak DM; Breitenfeld D
    Clin Chem; 1989 Jan; 35(1):151-3. PubMed ID: 2910557
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Relationship between sampling volume of primary serum tubes and spurious hemolysis.
    Lippi G; Musa R; Battistelli L; Cervellin G
    Clin Lab; 2012; 58(11-12):1187-91. PubMed ID: 23289188
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Heparin Concentration in Evacuated Tubes and Its Effect on pH, Ionized Calcium, Lactate, and Potassium in Venous Blood Gas Analysis.
    Mahler K; Kerlin R; Jones J; Li J
    Lab Med; 2023 Sep; 54(5):e157-e160. PubMed ID: 37095624
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Underfilling of vacuum blood collection tubes leads to increased lactate dehydrogenase activity in serum and heparin plasma samples.
    Neuwinger N; Meyer Zum Büschenfelde D; Tauber R; Kappert K
    Clin Chem Lab Med; 2020 Jan; 58(2):213-221. PubMed ID: 31665108
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Improved long-term stability of blood cocaine in evacuated collection tubes.
    Baselt RC; Yoshikawa D; Chang J; Li J
    J Forensic Sci; 1993 Jul; 38(4):935-7. PubMed ID: 8355007
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Cellular content in plasma of Becton-Dickinson lithium-heparin tubes: cause of unreliable results in the IFCC-recommended lactate dehydrogenase method.
    Bakker AJ; Bakker A; Renting-Wiering H
    Ann Clin Biochem; 2006 Nov; 43(Pt 6):510-2. PubMed ID: 17132285
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Effect of energy level of rations and time of blood sampling on the relative activity lf LDH isoenzymes in the serum of lambs].
    Hatzipanagiotou A; Liamadis D; Enbergs H
    Dtsch Tierarztl Wochenschr; 1998 Feb; 105(2):47-9. PubMed ID: 9528206
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Qualification process for evacuated blood collection tubes: application to the choice of serum collection tubes].
    Guerber F
    Ann Biol Clin (Paris); 2000; 58(6):754-6. PubMed ID: 11098178
    [No Abstract]   [Full Text] [Related]  

  • 17. Preanalytical variables in measurement of free (ionized) calcium in lithium heparin-containing blood collection tubes.
    Haverstick DM; Brill LB; Scott MG; Bruns DE
    Clin Chim Acta; 2009 May; 403(1-2):102-4. PubMed ID: 19361462
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Correct handling of serum separating gel tubes is of significance].
    Daae LN; Juell A; Lund PK
    Tidsskr Nor Laegeforen; 1989 Feb; 109(5):599-601. PubMed ID: 2922723
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Use of heparinized tubes for collection of blood intended for chemical analysis, especially for potassium determination].
    Michod J; Platsoukas C; Frei J
    Z Klin Chem Klin Biochem; 1970 Sep; 7(5):455-7. PubMed ID: 5505954
    [No Abstract]   [Full Text] [Related]  

  • 20. Use of randomized duplicate serum specimens to evaluate sampling error and analytical error.
    Bokelund H; Winkel P
    Z Klin Chem Klin Biochem; 1974 May; 12(5):254. PubMed ID: 4440162
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 6.