These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

100 related articles for article (PubMed ID: 2604062)

  • 21. Evaluation of sample hemolysis in blood collected by S-Monovette using vacuum or aspiration mode.
    Lippi G; Avanzini P; Musa R; Sandei F; Aloe R; Cervellin G
    Biochem Med (Zagreb); 2013; 23(1):64-9. PubMed ID: 23457766
    [TBL] [Abstract][Full Text] [Related]  

  • 22. [Determination and stability of 4 therapeutic drugs collected into evacuated tubes with serum gel separator].
    Vigier JP; Guerber F; Pinel N
    Ann Biol Clin (Paris); 2000; 58(6):738-9. PubMed ID: 11098172
    [No Abstract]   [Full Text] [Related]  

  • 23. Interindividual variability of hemolysis in plasma samples during pneumatic tube system transport.
    Gomez-Rioja R; Fernandez-Calle P; Alcaide MJ; Madero R; Oliver P; Iturzaeta JM; Buno A
    Clin Chem Lab Med; 2013 Oct; 51(10):e231-3. PubMed ID: 23633466
    [No Abstract]   [Full Text] [Related]  

  • 24. Femoral venipuncture for collection of multiple blood samples in the nonanesthetized rat.
    Horton ML; Olson CT; Hobson DW
    Am J Vet Res; 1986 Aug; 47(8):1781-2. PubMed ID: 3752689
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Pseudohyperkalemia in chronic lymphocytic leukemia: phlebotomy sites and pneumatic tubes.
    Sindhu SK; Hix JK; Fricke W
    Am J Kidney Dis; 2011 Feb; 57(2):354-5. PubMed ID: 21251549
    [No Abstract]   [Full Text] [Related]  

  • 26. [Blood and serum values of the Göttingen miniature swine. 3. Effect of endogenous and exogenous factors on serum enzyme activity].
    Maier O; Oldigs B; Hinsch W
    Zentralbl Veterinarmed A; 1983 Jan; 30(1):26-39. PubMed ID: 6405559
    [No Abstract]   [Full Text] [Related]  

  • 27. Effect of storage at various temperatures on the activity of cotton rat serum enzymes.
    Ezigbo JC; Storey DM
    Indian J Exp Biol; 1980 Jan; 18(1):96-7. PubMed ID: 7399590
    [No Abstract]   [Full Text] [Related]  

  • 28. [Evaluation of the Vacutainer SST tube].
    de Graeve J; Duplaquet Y; Bressan MF; Valdiguie P; Douau MA; Moussard C; Henry JC
    Ann Biol Clin (Paris); 1982; 40(4):335-6. PubMed ID: 7149352
    [No Abstract]   [Full Text] [Related]  

  • 29. Evaluation of pneumatic-tube system for delivery of blood specimens.
    Steige H; Jones JD
    Clin Chem; 1971 Dec; 17(12):1160-4. PubMed ID: 5118154
    [No Abstract]   [Full Text] [Related]  

  • 30. Variations in serum glucose, urea, creatinine and sodium and potassium as a consequence of delayed transport/processing of samples and delay in assays.
    Joshi AR
    JNMA J Nepal Med Assoc; 2006; 45(161):186-9. PubMed ID: 17160095
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Comparison of blood specimens from plain and gel vacuum blood collection tubes.
    Wiwanitkit V
    J Med Assoc Thai; 2001 May; 84(5):723-6. PubMed ID: 11560224
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Elevated results in a vitamin B12 assay when using serum separator blood collection tubes.
    Lowrey I; Smith G
    Ann Clin Biochem; 2003 Sep; 40(Pt 5):560-2. PubMed ID: 14503995
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Evaluation of the Du Pont Axial Separation system.
    Perkins SL; Adams GA
    Clin Chem; 1996 Sep; 42(9):1467-73. PubMed ID: 8787706
    [TBL] [Abstract][Full Text] [Related]  

  • 34. The use of evacuated tubes for blood collection in oral anticoagulant control.
    van den Besselaar AM; van Halem-Visser LP; Loeliger EA
    Thromb Haemost; 1983 Oct; 50(3):676-7. PubMed ID: 6648890
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Correction and reporting of potassium results in haemolysed samples.
    Dimeski G; Clague AE; Hickman PE
    Ann Clin Biochem; 2005 Mar; 42(Pt 2):119-23. PubMed ID: 15829120
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Accuracy of measurements of hemoglobin and potassium in blood samples from peripheral catheters.
    Fincher RK; Strong JS; Jackson JL
    Am J Crit Care; 1998 Nov; 7(6):439-43. PubMed ID: 9805118
    [TBL] [Abstract][Full Text] [Related]  

  • 37. [Influence of temperature and delayed centrifugation: stability studies of 28 analytes currently analysed].
    Foucher B; Pina G; Desjeux G; Prevosto JM; Chaulet JF; Cheminel V
    Ann Biol Clin (Paris); 2005; 63(1):93-100. PubMed ID: 15689318
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Aqueous lithium heparin is a superior anticoagulant to solid heparin for blood collection from the retro-orbital sinus of rats.
    Slaughter MR; Moen JS
    Lab Anim; 1991 Jul; 25(3):272-6. PubMed ID: 1921328
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Gentle blood aspiration and tube cushioning reduce pneumatic tube system interference in lactate dehydrogenase assays.
    Strubi-Vuillaume I; Carlier V; Obeuf C; Vasseur F; Maury JC; Maboudou P; Mangalaboyi J; Durocher A; Launay D; Noel C; Brousseau T
    Ann Clin Biochem; 2016 Mar; 53(Pt 2):295-7. PubMed ID: 25911571
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Speed of sample transportation by a pneumatic tube system can influence the degree of hemolysis.
    Tiwari AK; Pandey P; Dixit S; Raina V
    Clin Chem Lab Med; 2011 Nov; 50(3):471-4. PubMed ID: 22070350
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 5.