These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
121 related articles for article (PubMed ID: 26048845)
1. Bare conical nanopore embedded in polymer membrane for Cr(III) sensing. Zhai Q; Wang J; Jiang H; Wei Q; Wang E Talanta; 2015 Aug; 140():219-225. PubMed ID: 26048845 [TBL] [Abstract][Full Text] [Related]
2. Label-free histamine detection with nanofluidic diodes through metal ion displacement mechanism. Ali M; Ramirez P; Duznovic I; Nasir S; Mafe S; Ensinger W Colloids Surf B Biointerfaces; 2017 Feb; 150():201-208. PubMed ID: 27915002 [TBL] [Abstract][Full Text] [Related]
3. Voltage-Rectified Current and Fluid Flow in Conical Nanopores. Lan WJ; Edwards MA; Luo L; Perera RT; Wu X; Martin CR; White HS Acc Chem Res; 2016 Nov; 49(11):2605-2613. PubMed ID: 27689816 [TBL] [Abstract][Full Text] [Related]
4. Facile preparation of glutathione-stabilized gold nanoclusters for selective determination of chromium (III) and chromium (VI) in environmental water samples. Zhang H; Liu Q; Wang T; Yun Z; Li G; Liu J; Jiang G Anal Chim Acta; 2013 Apr; 770():140-6. PubMed ID: 23498696 [TBL] [Abstract][Full Text] [Related]
6. Reversing current rectification to improve DNA-sensing sensitivity in conical nanopores. Cai XH; Cao SH; Cai SL; Wu YY; Ajmal M; Li YQ Electrophoresis; 2019 Aug; 40(16-17):2098-2103. PubMed ID: 31020667 [TBL] [Abstract][Full Text] [Related]
7. Ultrasensitive sliver nanorods array SERS sensor for mercury ions. Song C; Yang B; Zhu Y; Yang Y; Wang L Biosens Bioelectron; 2017 Jan; 87():59-65. PubMed ID: 27522013 [TBL] [Abstract][Full Text] [Related]
8. Glutamine-containing "turn-on" fluorescence sensor for the highly sensitive and selective detection of chromium (III) ion in water. Zhao M; Ma L; Zhang M; Cao W; Yang L; Ma LJ Spectrochim Acta A Mol Biomol Spectrosc; 2013 Dec; 116():460-5. PubMed ID: 23973594 [TBL] [Abstract][Full Text] [Related]
9. Monoclonal antibody to trivalent chromium chelate complex and its application to measurement of the total chromium concentration. Sasaki K; Oguma S; Namiki Y; Ohmura N Anal Chem; 2009 May; 81(10):4005-9. PubMed ID: 19438265 [TBL] [Abstract][Full Text] [Related]
10. A novel fluorescent probe for Cr(3+) based on rhodamine-crown ether conjugate and its application to drinking water examination and bioimaging. Diao Q; Ma P; Lv L; Li T; Wang X; Song D Spectrochim Acta A Mol Biomol Spectrosc; 2016 Mar; 156():15-21. PubMed ID: 26641281 [TBL] [Abstract][Full Text] [Related]
11. A novel fluorescence-quenching immunochromatographic sensor for detection of the heavy metal chromium. Fu Q; Tang Y; Shi C; Zhang X; Xiang J; Liu X Biosens Bioelectron; 2013 Nov; 49():399-402. PubMed ID: 23800612 [TBL] [Abstract][Full Text] [Related]
12. Single glass nanopore-based regenerable sensing platforms with a non-immobilized polyglutamic acid probe for selective detection of cupric ions. Chen L; He H; Xu X; Jin Y Anal Chim Acta; 2015 Aug; 889():98-105. PubMed ID: 26343431 [TBL] [Abstract][Full Text] [Related]
13. Highly sensitive detection of chromium (III) ions by resonance Rayleigh scattering enhanced by gold nanoparticles. Chen M; Cai HH; Yang F; Lin D; Yang PH; Cai J Spectrochim Acta A Mol Biomol Spectrosc; 2014 Jan; 118():776-81. PubMed ID: 24144831 [TBL] [Abstract][Full Text] [Related]
14. Ultrasensitive and ultraselective impedimetric detection of Cr(VI) using crown ethers as high-affinity targeting receptors. Wei J; Guo Z; Chen X; Han DD; Wang XK; Huang XJ Anal Chem; 2015 Feb; 87(3):1991-8. PubMed ID: 25582866 [TBL] [Abstract][Full Text] [Related]
15. Selective extraction and release using (EDTA-Ni)-layered double hydroxide coupled with catalytic oxidation of 3,3',5,5'-tetramethylbenzidine for sensitive detection of copper ion. Tang S; Chang Y; Chia GH; Lee HK Anal Chim Acta; 2015 Jul; 885():106-13. PubMed ID: 26231895 [TBL] [Abstract][Full Text] [Related]
16. The electron-transfer based interaction between transition metal ions and photoluminescent graphene quantum dots (GQDs): a platform for metal ion sensing. Huang H; Liao L; Xu X; Zou M; Liu F; Li N Talanta; 2013 Dec; 117():152-7. PubMed ID: 24209324 [TBL] [Abstract][Full Text] [Related]
18. Selective and sensitive detection of chromium(VI) in waters using electrospray ionization mass spectrometry. Weldy E; Wolff C; Miao Z; Chen H Sci Justice; 2013 Sep; 53(3):293-300. PubMed ID: 23937937 [TBL] [Abstract][Full Text] [Related]
19. A chelate complex-enhanced luminol system for selective determination of Co(II), Fe(II) and Cr(III). Kim KM; Kim YH; Oh SH; Lee SH Luminescence; 2013; 28(3):372-7. PubMed ID: 22715144 [TBL] [Abstract][Full Text] [Related]
20. A colorimetric nitrite detection system with excellent selectivity and high sensitivity based on Ag@Au nanoparticles. Li T; Li Y; Zhang Y; Dong C; Shen Z; Wu A Analyst; 2015 Feb; 140(4):1076-81. PubMed ID: 25564225 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]