  • 41. Indirect versus direct laryngoscopy for routine nasotracheal intubation.
    Puchner W; Drabauer L; Kern K; Mayer C; Bierbaumer J; Rehak PH; Gombotz H
    J Clin Anesth; 2011 Jun; 23(4):280-5. PubMed ID: 21663811
    [TBL] [Abstract][Full Text] [Related]  

  • 42. The GlideScope Ranger video laryngoscope can be useful in airway management of entrapped patients.
    Nakstad AR; Sandberg M
    Acta Anaesthesiol Scand; 2009 Nov; 53(10):1257-61. PubMed ID: 19681773
    [TBL] [Abstract][Full Text] [Related]  

  • 43. "Tube first or scope first": a novel technique for endotracheal tube insertion during difficult GlideScope intubation with reduced mouth opening.
    Singh J; Singh M; Anand LK; Kapoor D
    J Clin Anesth; 2016 Aug; 32():106-7. PubMed ID: 27290956
    [No Abstract]   [Full Text] [Related]  

  • 44. [GlideScope videolaryngoscope: a clinical assessment of its performance in 200 consecutive patients].
    Hirabayashi Y; Hakozaki T; Fujisawa K; Yamada M; Suzuki H; Satoh M; Hotta K; Igarashi T; Taga N; Seo N
    Masui; 2007 Sep; 56(9):1059-64. PubMed ID: 17877047
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Comparison of the Cobalt Glidescope video laryngoscope with conventional laryngoscopy in simulated normal and difficult infant airways.
    White M; Weale N; Nolan J; Sale S; Bayley G
    Paediatr Anaesth; 2009 Nov; 19(11):1108-12. PubMed ID: 19659602
    [TBL] [Abstract][Full Text] [Related]  

  • 46. [Glidescope cobalt videolaryngoscope].
    Hirabayashi Y; Kuratani N; Masaki E
    Masui; 2013 Feb; 62(2):233-8. PubMed ID: 23479934
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Awake video laryngoscope intubation: case report of a patient with a nasopharyngeal mass.
    Dotson M
    AANA J; 2012 Oct; 80(5):347-53. PubMed ID: 26050275
    [TBL] [Abstract][Full Text] [Related]  

  • 48. GlideScope® vs flexible fibreoptic scope for elective intubation in obese patients.
    Abdelmalak BB; Bernstein E; Egan C; Abdallah R; You J; Sessler DI; Doyle DJ
    Anaesthesia; 2011 Jul; 66(7):550-5. PubMed ID: 21564041
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Airway management in pediatric patients using the Glidescope Cobalt®: a feasibility study.
    Ilies C; Fudickar A; Thee C; Dütschke P; Hanss R; Doerges V; Bein B
    Minerva Anestesiol; 2012 Sep; 78(9):1019-25. PubMed ID: 22643539
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Methods to Improve Success With the GlideScope Video Laryngoscope.
    Nemec D; Austin PN; Silvestro LS
    AANA J; 2015 Dec; 83(6):389-97. PubMed ID: 26742332
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Clinical benefits of visualization of airway anatomy and manipulation of the endotracheal tube cuff with the GlideScope in the morbidly obese patient during tracheotomy.
    Hartman MT; Lang J
    AANA J; 2009 Dec; 77(6):437-8. PubMed ID: 20108730
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Comparison of different video laryngoscopes for emergency intubation in a standardized airway manikin with immobilized cervical spine by experienced anaesthetists. A randomized, controlled crossover trial.
    Wetsch WA; Spelten O; Hellmich M; Carlitscheck M; Padosch SA; Lier H; Böttiger BW; Hinkelbein J
    Resuscitation; 2012 Jun; 83(6):740-5. PubMed ID: 22155448
    [TBL] [Abstract][Full Text] [Related]  

  • 53. A comparative study of the Parker Flex-Tip tube versus standard portex tube for oral fiberoptic intubation in bronchoscopy performed by pulmonologists with limited experience.
    Yamauchi H; Nakayama M; Yamamoto S; Sata M; Mato N; Bando M; Hagiwara K
    Respir Investig; 2021 Mar; 59(2):223-227. PubMed ID: 33139234
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Direct versus video laryngoscopic intubation by novice prehospital intubators with and without chest compressions: A pilot manikin study.
    Kim YM; Kang HG; Kim JH; Chung HS; Yim HW; Jeong SH
    Prehosp Emerg Care; 2011; 15(1):98-103. PubMed ID: 21034232
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Tracheal intubation during chest compressions using Pentax-AWS(®), GlideScope (®), and Macintosh laryngoscope: a randomized crossover trial using a mannequin.
    Shin DH; Choi PC; Han SK
    Can J Anaesth; 2011 Aug; 58(8):733-9. PubMed ID: 21630116
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Comparison of the GlideScope video laryngoscope and Macintosh laryngoscope in simulated tracheal intubation scenarios.
    Kim HJ; Chung SP; Park IC; Cho J; Lee HS; Park YS
    Emerg Med J; 2008 May; 25(5):279-82. PubMed ID: 18434462
    [TBL] [Abstract][Full Text] [Related]  

  • 57. [Nasal endotracheal intubation using GlideScope].
    Hirabayashi Y; Hakozaki T; Fujisawa K; Hiruta M; Niwa Y; Sata N; Sinohara T; Taira K; Takaku Y; Kayamoto S
    Masui; 2007 Aug; 56(8):962-4. PubMed ID: 17715693
    [TBL] [Abstract][Full Text] [Related]  

  • 58. [Awake fiberoptic intubation with Parker Flex-Tip tracheal tube in a patient with obesity, goiter, and laryngo-tracheal shift].
    Suzuki M; Mizuno J; Harashima T; Ichinokawa Y; Morita S
    Masui; 2010 Jun; 59(6):731-3. PubMed ID: 20560376
    [TBL] [Abstract][Full Text] [Related]  

  • 59. A randomised controlled trial comparing the GlideScope(®) and the Macintosh laryngoscope for double-lumen endobronchial intubation.
    Russell T; Slinger P; Roscoe A; McRae K; Van Rensburg A
    Anaesthesia; 2013 Dec; 68(12):1253-8. PubMed ID: 24219251
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Stylet- or forceps-guided tube exchanger to facilitate GlideScope intubation in simulated difficult intubations--a randomised controlled trial.
    Jeon WJ; Shim JH; Cho SY; Baek SJ
    Anaesthesia; 2013 Jun; 68(6):585-90. PubMed ID: 23590463
    [TBL] [Abstract][Full Text] [Related]  