These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

104 related articles for article (PubMed ID: 26056050)

  • 1. Learning curve and intra/interobserver agreement of transient elastography in chronic hepatitis C patients with or without HIV co-infection.
    Perazzo H; Fernandes FF; Soares JC; Fittipaldi J; Cardoso SW; Grinsztejn B; Veloso VG
    Clin Res Hepatol Gastroenterol; 2016 Feb; 40(1):73-82. PubMed ID: 26056050
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Interobserver variability in transient elastography analysis of patients with chronic hepatitis C.
    Perazzo H; Fernandes FF; Gomes A; Terra C; Perez RM; Figueiredo FA
    Liver Int; 2015 May; 35(5):1533-9. PubMed ID: 24684234
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Interobserver concordance in the assessment of liver fibrosis in HIV/HCV-coinfected patients using transient elastometry.
    Neukam K; Recio E; Camacho A; Macías J; Rivero A; Mira JA; López C; Almeida C; de la Torre J; Pineda JA
    Eur J Gastroenterol Hepatol; 2010 Jul; 22(7):801-7. PubMed ID: 19773664
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Interobserver agreement and diagnostic accuracy of shearwave elastography for the staging of hepatitis C virus-associated liver fibrosis.
    Kaposi PN; Unger Z; Fejér B; Kucsa A; Tóth A; Folhoffer A; Szalay F; Bérczi V
    J Clin Ultrasound; 2020 Feb; 48(2):67-74. PubMed ID: 31463955
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Reproducibility of transient elastography in the evaluation of liver fibrosis in patients with chronic liver disease.
    Fraquelli M; Rigamonti C; Casazza G; Conte D; Donato MF; Ronchi G; Colombo M
    Gut; 2007 Jul; 56(7):968-73. PubMed ID: 17255218
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Baseline values and changes in liver stiffness measured by transient elastography are associated with severity of fibrosis and outcomes of patients with primary sclerosing cholangitis.
    Corpechot C; Gaouar F; El Naggar A; Kemgang A; Wendum D; Poupon R; Carrat F; Chazouillères O
    Gastroenterology; 2014 Apr; 146(4):970-9; quiz e15-6. PubMed ID: 24389304
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Accuracy of fibroscan, compared with histology, in analysis of liver fibrosis in patients with hepatitis B or C: a United States multicenter study.
    Afdhal NH; Bacon BR; Patel K; Lawitz EJ; Gordon SC; Nelson DR; Challies TL; Nasser I; Garg J; Wei LJ; McHutchison JG
    Clin Gastroenterol Hepatol; 2015 Apr; 13(4):772-9.e1-3. PubMed ID: 25528010
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [The efficacy of transient liver elastography overweight patients with chronic liver diseases].
    Trufanova IuM; Topil'skaia NV; Morozov SV; Isakov VA; Kaganov BS
    Eksp Klin Gastroenterol; 2010; (5):19-26. PubMed ID: 20731131
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Interobserver concordance in controlled attenuation parameter measurement, a novel tool for the assessment of hepatic steatosis on the basis of transient elastography.
    Recio E; Cifuentes C; Macías J; Mira JA; Parra-Sánchez M; Rivero-Juárez A; Almeida C; Pineda JA; Neukam K
    Eur J Gastroenterol Hepatol; 2013 Aug; 25(8):905-11. PubMed ID: 23459105
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Performance of real-time strain elastography, transient elastography, and aspartate-to-platelet ratio index in the assessment of fibrosis in chronic hepatitis C.
    Ferraioli G; Tinelli C; Malfitano A; Dal Bello B; Filice G; Filice C; ; Above E; Barbarini G; Brunetti E; Calderon W; Di Gregorio M; Lissandrin R; Ludovisi S; Maiocchi L; Michelone G; Mondelli M; Patruno SF; Perretti A; Poma G; Sacchi P; Zaramella M; Zicchetti M
    AJR Am J Roentgenol; 2012 Jul; 199(1):19-25. PubMed ID: 22733889
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Liver stiffness and aspartate aminotransferase levels predict the risk for liver fibrosis progression in hepatitis C virus/HIV-coinfected patients.
    Gonzalez FA; Van den Eynde E; Perez-Hoyos S; Navarro J; Curran A; Burgos J; Falcó V; Ocaña I; Ribera E; Crespo M
    HIV Med; 2015 Apr; 16(4):211-8. PubMed ID: 25234826
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison of transient elastography and liver biopsy for the assessment of liver fibrosis in HIV/hepatitis C virus-coinfected patients and correlation with noninvasive serum markers.
    Sánchez-Conde M; Montes-Ramírez ML; Miralles P; Alvarez JM; Bellón JM; Ramírez M; Arribas JR; Gutiérrez I; López JC; Cosín J; Alvarez E; González J; Berenguer J
    J Viral Hepat; 2010 Apr; 17(4):280-6. PubMed ID: 19732322
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Interobserver discrepancy in liver fibrosis using transient elastography.
    Roca B; Resino E; Torres V; Herrero E; Penades M
    J Viral Hepat; 2012 Oct; 19(10):711-5. PubMed ID: 22967102
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Accuracy of real-time shear wave elastography for assessing liver fibrosis in chronic hepatitis C: a pilot study.
    Ferraioli G; Tinelli C; Dal Bello B; Zicchetti M; Filice G; Filice C;
    Hepatology; 2012 Dec; 56(6):2125-33. PubMed ID: 22767302
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of transient elastography (FibroScan), FibroTest, APRI and two algorithms combining these non-invasive tests for liver fibrosis staging in HIV/HCV coinfected patients: ANRS CO13 HEPAVIH and FIBROSTIC collaboration.
    Castera L; Winnock M; Pambrun E; Paradis V; Perez P; Loko MA; Asselineau J; Dabis F; Degos F; Salmon D
    HIV Med; 2014 Jan; 15(1):30-9. PubMed ID: 24007567
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Insulin resistance is associated with liver stiffness in HIV/HCV co-infected patients.
    Merchante N; Rivero A; de Los Santos-Gil I; Merino D; Márquez M; López-Ruz MA; Rodríguez-Baño J; Del Valle J; Camacho A; Sanz-Sanz J; Macías J; Pérez-Camacho I; Gómez-Mateos J; Moro A; Pineda JA
    Gut; 2009 Dec; 58(12):1654-60. PubMed ID: 19625279
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Quantitative elastography of liver fibrosis and spleen stiffness in chronic hepatitis B carriers: comparison of shear-wave elastography and transient elastography with liver biopsy correlation.
    Leung VY; Shen J; Wong VW; Abrigo J; Wong GL; Chim AM; Chu SH; Chan AW; Choi PC; Ahuja AT; Chan HL; Chu WC
    Radiology; 2013 Dec; 269(3):910-8. PubMed ID: 23912619
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Impact of liver steatosis on the correlation between liver stiffness and fibrosis measured by transient elastography in patients coinfected with human immunodeficiency virus and hepatitis C virus.
    Sánchez-Conde M; Montes Ramírez ML; Bellón Cano JM; Caminoa A; Alvarez Rodríguez F; González Garcia J; Miralles Martín P; Bernardino de la Serna I; Bernardo de Quirós JC; Arribas López JR; Cosín Ochaíta J; Pascual Pareja JF; Alvarez E; Berenguer JB
    J Viral Hepat; 2011 Jul; 18(7):e278-83. PubMed ID: 21129129
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Performance of a new elastographic method (ARFI technology) compared to unidimensional transient elastography in the noninvasive assessment of chronic hepatitis C. Preliminary results.
    Lupsor M; Badea R; Stefanescu H; Sparchez Z; Branda H; Serban A; Maniu A
    J Gastrointestin Liver Dis; 2009 Sep; 18(3):303-10. PubMed ID: 19795024
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Outreach screening of drug users for cirrhosis with transient elastography.
    Moessner BK; Jørgensen TR; Skamling M; Vyberg M; Junker P; Pedersen C; Christensen PB
    Addiction; 2011 May; 106(5):970-6. PubMed ID: 21182552
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.