BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

151 related articles for article (PubMed ID: 26069070)

  • 1. [Direct and indirect ion selective electrodes methods: the differences specified through a case of Waldenström's macroglobulinemia].
    Zelmat MS
    Ann Biol Clin (Paris); 2015; 73(3):345-52. PubMed ID: 26069070
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Disagreement between ion selective electrode direct and indirect sodium measurements: estimation of the problem in a tertiary referral hospital.
    Dimeski G; Morgan TJ; Presneill JJ; Venkatesh B
    J Crit Care; 2012 Jun; 27(3):326.e9-16. PubMed ID: 22227082
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Pseudohyponatremia: Mechanism, Diagnosis, Clinical Associations and Management.
    Aziz F; Sam R; Lew SQ; Massie L; Misra M; Roumelioti ME; Argyropoulos CP; Ing TS; Tzamaloukas AH
    J Clin Med; 2023 Jun; 12(12):. PubMed ID: 37373769
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Prevalence of Clinically Significant Differences in Sodium Measurements Due to Abnormal Protein Concentrations Using an Indirect Ion-Selective Electrode Method.
    Katrangi W; Baumann NA; Nett RC; Karon BS; Block DR
    J Appl Lab Med; 2019 Nov; 4(3):427-432. PubMed ID: 31659081
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A new method for determining plasma water content: application in pseudohyponatremia.
    Nguyen MK; Ornekian V; Butch AW; Kurtz I
    Am J Physiol Renal Physiol; 2007 May; 292(5):F1652-6. PubMed ID: 17299138
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effects of total plasma protein concentration on plasma sodium, potassium and chloride measurements by an indirect ion selective electrode measuring system.
    Dimeski G; Barnett RJ
    Crit Care Resusc; 2005 Mar; 7(1):12-5. PubMed ID: 16548813
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Resolving Pseudohyponatremia: Validation of Plasma Sodium on Radiometer ABL800 Blood Gas Analyzers for Immediate Reflex Testing.
    Vera MA; Sutphin A; Hansen L; El-Khoury JM
    Lab Med; 2022 Sep; 53(5):e105-e108. PubMed ID: 35015890
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Prevalence of pseudonatremia in a clinical laboratory - role of the water content.
    Langelaan ML; Kamp L; Zandijk E; Raijmakers MT
    Clin Chem Lab Med; 2017 Mar; 55(4):546-553. PubMed ID: 27676606
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Preventing pseudohyponatremia: Intralipid®-based lipemia cutoffs for sodium are inappropriate.
    Koch CD; Vera MA; Messina J; Price N; Durant TJS; El-Khoury JM
    Clin Chim Acta; 2021 Sep; 520():63-66. PubMed ID: 34077753
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Hepatocellular carcinoma followed by Waldenström's macroglobulinemia: a case report.
    Hasegawa K; Kubota K; Hirai H; Imai Y; Midorikawa Y; Makuuchi M
    Hepatogastroenterology; 2000; 47(33):842-5. PubMed ID: 10919044
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The challenges of sodium measurements: indirect versus direct ion-selective method.
    Refardt J; Sailer CO; Chifu I; Winzeler B; Schnyder I; Fassnacht M; Fenske W; Christ-Crain M
    Eur J Endocrinol; 2019 Aug; 181(2):193-199. PubMed ID: 31167167
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Glucose interference in direct ion-sensitive electrode sodium measurements.
    Al-Musheifri A; Jones GR
    Ann Clin Biochem; 2008 Sep; 45(Pt 5):530-2. PubMed ID: 18753432
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effect of low serum total protein on sodium and potassium measurement by ion-selective electrodes in critically ill patients.
    Chow E; Fox N; Gama R
    Br J Biomed Sci; 2008; 65(3):128-31. PubMed ID: 18986099
    [TBL] [Abstract][Full Text] [Related]  

  • 14. PSEUDOHYPONATREMIA IN THE SETTING OF HYPERCHOLESTEROLEMIA.
    El Hage L; Reineks E; Nasr C
    AACE Clin Case Rep; 2019; 5(2):e172-e174. PubMed ID: 31967027
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Waldenström's macroglobulinemia with an uncommon presentation].
    Trueba F; Maslin J; Coutant G; Guymar S; Vigezzi JF; Desangles F; Nizou JY; Nicand E
    Ann Biol Clin (Paris); 2006; 64(1):73-5. PubMed ID: 16420993
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Plasma sodium measurements by direct ion selective methods in laboratory and point of care may not be clinically interchangeable.
    Weld BA; Morgan TJ; Presneill JJ; Weier S; Cowley D
    J Clin Monit Comput; 2017 Oct; 31(5):1103-1109. PubMed ID: 27683272
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Sodium determination in biological fluids].
    Cristol JP; Balint B; Canaud B; Daurés MF
    Nephrol Ther; 2007 Sep; 3 Suppl 2():S104-11. PubMed ID: 17939965
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Relationship of the absolute difference between direct and indirect ion selective electrode measurement of serum sodium and the total protein concentration.
    Jones BJ; Twomey PJ
    J Clin Pathol; 2008 May; 61(5):645-7. PubMed ID: 18441158
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Recommendation for measuring and reporting chloride by ISEs in undiluted serum, plasma or blood.
    Rayana MC; Burnett RW; Covington AK; D'Orazio P; Fogh-Andersen N; Jacobs E; Kataky R; Külpmann WR; Kuwa K; Larsson L; Lewenstam A; Maas AH; Mager G; Naskalski JW; Okorodudu AO; Ritter C; St John A;
    Clin Chem Lab Med; 2006; 44(3):346-52. PubMed ID: 16519610
    [TBL] [Abstract][Full Text] [Related]  

  • 20. MYD88 L265P somatic mutation in Waldenström's macroglobulinemia.
    Treon SP; Xu L; Yang G; Zhou Y; Liu X; Cao Y; Sheehy P; Manning RJ; Patterson CJ; Tripsas C; Arcaini L; Pinkus GS; Rodig SJ; Sohani AR; Harris NL; Laramie JM; Skifter DA; Lincoln SE; Hunter ZR
    N Engl J Med; 2012 Aug; 367(9):826-33. PubMed ID: 22931316
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.