These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

148 related articles for article (PubMed ID: 26069406)

  • 1. Stereomicroscopic evaluation of dentinal defects induced by new rotary system: "ProTaper NEXT".
    Shori DD; Shenoi PR; Baig AR; Kubde R; Makade C; Pandey S
    J Conserv Dent; 2015; 18(3):210-3. PubMed ID: 26069406
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Dentinal microcrack formation during root canal preparations by different NiTi rotary instruments and the self-adjusting file.
    Yoldas O; Yilmaz S; Atakan G; Kuden C; Kasan Z
    J Endod; 2012 Feb; 38(2):232-5. PubMed ID: 22244643
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparative Analysis of Dentinal Crack Formation Following Root Canal Instrumentation with Hand K-Flex Files, ProTaper Next, and Self-adjusting Files.
    Jacob J; Paul M; Sara B; Steaphen P; Philip N; Mathew J
    J Contemp Dent Pract; 2019 Aug; 20(8):935-939. PubMed ID: 31797850
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Incidence of Dentinal Root Defects Caused by RECIPROC Blue, ProTaper Gold, ProTaper NEXT and RECIPROC Nickel Titanium Rotary Instruments.
    Hussien SW; Al-Gharrawi HA
    J Contemp Dent Pract; 2019 Mar; 20(3):291-297. PubMed ID: 31204320
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of dentinal damage induced by different nickel-titanium rotary instruments during canal preparation: An in vitro study.
    Garg S; Mahajan P; Thaman D; Monga P
    J Conserv Dent; 2015; 18(4):302-5. PubMed ID: 26180415
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Assessment of dentinal damage during canal preparation using reciprocating and rotary files.
    Kansal R; Rajput A; Talwar S; Roongta R; Verma M
    J Endod; 2014 Sep; 40(9):1443-6. PubMed ID: 25146029
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effect of Root Canal Preparation Techniques on Crack Formation in Root Dentin.
    Shantiaee Y; Dianat O; Mosayebi G; Namdari M; Tordik P
    J Endod; 2019 Apr; 45(4):447-452. PubMed ID: 30827767
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of Root Dentinal Damage Associated with ProTaper Gold, WaveOne Gold, and ProTaper Next during Cleaning and Shaping Procedures: An
    Koroth S; Ponnappa KC; Simon EP; Bharath S; Vivek VJ; Raveendran C
    J Pharm Bioallied Sci; 2021 Nov; 13(Suppl 2):S1098-S1101. PubMed ID: 35017937
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The ability of different nickel-titanium rotary instruments to induce dentinal damage during canal preparation.
    Bier CA; Shemesh H; Tanomaru-Filho M; Wesselink PR; Wu MK
    J Endod; 2009 Feb; 35(2):236-8. PubMed ID: 19166781
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Evaluation of Radicular Dentin Microcracks Formation after Instrumentation with NiTi Hand and Rotary File System: A Stereomicroscopic Study.
    Kumar A; Kaul S; Kuriakose F; James J; Joy B; Malik R
    J Contemp Dent Pract; 2020 Nov; 21(11):1233-1237. PubMed ID: 33850068
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A Stereomicroscopic Evaluation of Dentinal Cracks at Different Instrumentation Lengths by Using Different Rotary Files (ProTaper Universal, ProTaper Next, and HyFlex CM): An Ex Vivo Study.
    Ashraf F; Shankarappa P; Misra A; Sawhney A; Sridevi N; Singh A
    Scientifica (Cairo); 2016; 2016():8379865. PubMed ID: 27446636
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Stereomicroscopic evaluation of defects caused by torsional fatigue in used hand and rotary nickel-titanium instruments.
    Asthana G; Kapadwala MI; Parmar GJ
    J Conserv Dent; 2016; 19(2):120-4. PubMed ID: 27099415
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The effects of Mtwo, R-Endo, and D-RaCe retreatment instruments on the incidence of dentinal defects during the removal of root canal filling material.
    Topçuoğlu HS; Demirbuga S; Tuncay Ö; Pala K; Arslan H; Karataş E
    J Endod; 2014 Feb; 40(2):266-70. PubMed ID: 24461416
    [TBL] [Abstract][Full Text] [Related]  

  • 14. "Dentinal microcracks after root canal preparation" a comparative evaluation with hand, rotary and reciprocating instrumentation.
    Priya NT; Chandrasekhar V; Anita S; Tummala M; Raj TB; Badami V; Kumar P; Soujanya E
    J Clin Diagn Res; 2014 Dec; 8(12):ZC70-2. PubMed ID: 25654036
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evaluation of debris extruded apically during the removal of root canal filling material using ProTaper, D-RaCe, and R-Endo rotary nickel-titanium retreatment instruments and hand files.
    Topçuoğlu HS; Aktı A; Tuncay Ö; Dinçer AN; Düzgün S; Topçuoğlu G
    J Endod; 2014 Dec; 40(12):2066-9. PubMed ID: 25443282
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A Comparative SEM Investigation of Smear Layer Remaining on Dentinal Walls by Three Rotary NiTi Files with Different Cross Sectional Designs in Moderately Curved Canals.
    Sharma G; Kakkar P; Vats A
    J Clin Diagn Res; 2015 Mar; 9(3):ZC43-7. PubMed ID: 25954704
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Evaluation of microcrack formation during root canal preparation using hand, rotary files and self-adjusting file in primary teeth: An in vitro study.
    Panda A; Shah K; Budakoti V; Dere K; Virda M; Jani J
    J Dent Res Dent Clin Dent Prospects; 2021; 15(1):35-41. PubMed ID: 33927839
    [No Abstract]   [Full Text] [Related]  

  • 18. Evaluation of dentinal defects during root canal preparation using thermomechanically processed nickel-titanium files.
    Kesim B; Sagsen B; Aslan T
    Eur J Dent; 2017; 11(2):157-161. PubMed ID: 28729785
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effects of ProTaper Universal, ProTaper Next, and HyFlex instruments on crack formation in dentin.
    Capar ID; Arslan H; Akcay M; Uysal B
    J Endod; 2014 Sep; 40(9):1482-4. PubMed ID: 25146038
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparative evaluation of dentinal crack formation after root canal preparation with Neoendo Flex and Mani Silk files: An
    Guha A; Pandharikar R; Shivangi S; Rao RD; Verma M; Jain AK
    J Conserv Dent; 2020; 23(5):468-472. PubMed ID: 33911355
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.