These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
124 related articles for article (PubMed ID: 2607323)
41. Flow injection flame atomic absorption spectrometry for slurry atomization. Determination of iron, calcium and magnesium in samples with high silica content. García IL; Cortéz JA; Córdoba MH Talanta; 1993 Nov; 40(11):1677-85. PubMed ID: 18965839 [TBL] [Abstract][Full Text] [Related]
42. A comparison of reference method values for sodium, potassium and chloride with method-dependent assigned values. Külpmann WR; Lagemann J; Sander R; Maibaum P J Clin Chem Clin Biochem; 1985 Dec; 23(12):865-74. PubMed ID: 3831226 [TBL] [Abstract][Full Text] [Related]
43. [Determination of calcium and magnesium in wheat flour by suspension sampling-flame atomic absorption spectrometry]. Liu L; Zhang Q; Hu Y Guang Pu Xue Yu Guang Pu Fen Xi; 1999 Jun; 19(3):424-5. PubMed ID: 15819080 [TBL] [Abstract][Full Text] [Related]
44. Comparison of flame atomic absorption spectrometry (FAAS) and Cerimetric methods for the determination of ferrous sulfate content of some pharmaceutical products. Zahra R; Nadere R; Azam G Pak J Pharm Sci; 2008 Oct; 21(4):396-9. PubMed ID: 18930861 [TBL] [Abstract][Full Text] [Related]
45. Determination of calcium, magnesium, sodium, and potassium in foodstuffs by using a microsampling flame atomic absorption spectrometric method after closed-vessel microwave digestion: method validation. Chekri R; Noël L; Vastel C; Millour S; Kadar A; Guérin T J AOAC Int; 2010; 93(6):1888-96. PubMed ID: 21313817 [TBL] [Abstract][Full Text] [Related]
46. A method for determining the total magnesium, calcium, sodium and potassium contents of human platelets. Touyz RM; Milne FJ Miner Electrolyte Metab; 1991; 17(3):173-8. PubMed ID: 1779939 [TBL] [Abstract][Full Text] [Related]
47. Variations of zinc, calcium and magnesium in normal subjects and in patients with neoplasias. Chirulescu Z; Chiriloiu C; Suciu A; Pîrvulescu R Med Interne; 1987; 25(4):257-61. PubMed ID: 3423702 [TBL] [Abstract][Full Text] [Related]
48. [Determination of calcium, magnesium, iron and copper in serum by flame atomic absorption spectrophotometry]. Lin SM; Tsai JL; Pan TC Gaoxiong Yi Xue Ke Xue Za Zhi; 1986 Aug; 2(8):486-94. PubMed ID: 3330142 [No Abstract] [Full Text] [Related]
49. Solid phase preconcentration of iron as methylthymol blue complex on naphthalene-tetraoctylammonium bromide adsorbent with subsequent flame atomic absorption determination. Pourreza N; Mousavi HZ Talanta; 2004 Sep; 64(1):264-7. PubMed ID: 18969598 [TBL] [Abstract][Full Text] [Related]
50. Measurement of endogenous lithium levels in serum and urine by electrothermal atomic absorption spectrometry: a method with potential clinical applications. Miller NL; Durr JA; Alfrey AC Anal Biochem; 1989 Nov; 182(2):245-9. PubMed ID: 2610339 [TBL] [Abstract][Full Text] [Related]
51. Ultrasound-assisted extraction for the determination of Cu, Mn, Ca, and Mg in alternative oilseed crops using flame atomic absorption spectrometry. Peronico VC; Raposo JL Food Chem; 2016 Apr; 196():1287-92. PubMed ID: 26593618 [TBL] [Abstract][Full Text] [Related]
52. Lithium effects on serum calcium, magnesium and phosphate, in rats. Plenge P; Mellerup ET Psychopharmacology (Berl); 1976 Sep; 49(2):187-90. PubMed ID: 825906 [TBL] [Abstract][Full Text] [Related]
53. Comparison of slurry sampling and microwave-assisted digestion for calcium, magnesium, iron, copper and zinc determination in fish tissue samples by flame atomic absorption spectrometry. Bugallo RA; Segade SR; Gómez EF Talanta; 2007 Apr; 72(1):60-5. PubMed ID: 19071582 [TBL] [Abstract][Full Text] [Related]
54. Lithium determinations evaluated in eight analyzers. Sampson M; Ruddel M; Elin RJ Clin Chem; 1994 Jun; 40(6):869-72. PubMed ID: 8087980 [TBL] [Abstract][Full Text] [Related]
55. Direct determination of calcium and magnesium in serum using flow-injection analysis and atomic absorption spectroscopy. Rocks BF; Sherwood RA; Riley C Ann Clin Biochem; 1984 Jan; 21 ( Pt 1)():51-6. PubMed ID: 6712136 [TBL] [Abstract][Full Text] [Related]
56. Correlation of Calcium and Magnesium Levels in the Biological Samples of Different Types of Acute Leukemia Children. Afridi HI; Kazi TG; Talpur FN Biol Trace Elem Res; 2018 Dec; 186(2):395-406. PubMed ID: 29682679 [TBL] [Abstract][Full Text] [Related]
58. Spectrophotometric determination of magnesium in pharmaceutical preparations by cost-effective sequential injection analysis. Tesfaldet ZO; van Staden JF; Stefan RI Talanta; 2004 Nov; 64(4):981-8. PubMed ID: 18969700 [TBL] [Abstract][Full Text] [Related]
59. Evaluation of three first-generation ion-selective electrode analyzers for lithium: systematic errors, frequency of random interferences, and recommendations based on comparison with flame atomic emission spectrometry. Okorodudu AO; Burnett RW; McComb RB; Bowers GN Clin Chem; 1990 Jan; 36(1):104-10. PubMed ID: 2297898 [TBL] [Abstract][Full Text] [Related]
60. Studies on measurement of plasma magnesium: application of the Magon dye method to the "Monarch" centrifugal analyzer. Barbour HM; Davidson W Clin Chem; 1988 Oct; 34(10):2103-5. PubMed ID: 3168223 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]