These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

307 related articles for article (PubMed ID: 26074572)

  • 21. Timing and probability of crosstalk in a dense CMOS SPAD array in pulsed TOF applications.
    Jahromi S; Kostamovaara J
    Opt Express; 2018 Aug; 26(16):20622-20632. PubMed ID: 30119371
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Avalanche photodiodes and quenching circuits for single-photon detection.
    Cova S; Ghioni M; Lacaita A; Samori C; Zappa F
    Appl Opt; 1996 Apr; 35(12):1956-76. PubMed ID: 21085320
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Room temperature operation of germanium-silicon single-photon avalanche diode.
    Na N; Lu YC; Liu YH; Chen PW; Lai YC; Lin YR; Lin CC; Shia T; Cheng CH; Chen SL
    Nature; 2024 Mar; 627(8003):295-300. PubMed ID: 38383784
    [TBL] [Abstract][Full Text] [Related]  

  • 24. High-voltage integrated active quenching circuit for single photon count rate up to 80 Mcounts/s.
    Acconcia G; Rech I; Gulinatti A; Ghioni M
    Opt Express; 2016 Aug; 24(16):17819-31. PubMed ID: 27505749
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Noise and Breakdown Characterization of SPAD Detectors with Time-Gated Photon-Counting Operation.
    Mahmoudi H; Hofbauer M; Goll B; Zimmermann H
    Sensors (Basel); 2021 Aug; 21(16):. PubMed ID: 34450728
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Custom silicon technology for SPAD-arrays with red-enhanced sensitivity and low timing jitter.
    Gulinatti A; Ceccarelli F; Ghioni M; Rech I
    Opt Express; 2021 Feb; 29(3):4559-4581. PubMed ID: 33771031
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Performance of Active-Quenching SPAD Array Based on the Tri-State Gates of FPGA and Packaged with Bare Chip Stacking.
    Liu L; Lv W; Liu J; Zhang X; Liang K; Yang R; Han D
    Sensors (Basel); 2023 Apr; 23(9):. PubMed ID: 37177518
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Avalanche Transients of Thick 0.35 µm CMOS Single-Photon Avalanche Diodes.
    Goll B; Steindl B; Zimmermann H
    Micromachines (Basel); 2020 Sep; 11(9):. PubMed ID: 32961756
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Performance trade-offs in single-photon avalanche diode miniaturization.
    Finkelstein H; Hsu MJ; Zlatanovic S; Esener S
    Rev Sci Instrum; 2007 Oct; 78(10):103103. PubMed ID: 17979402
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Modeling and Analysis of Capacitive Relaxation Quenching in a Single Photon Avalanche Diode (SPAD) Applied to a CMOS Image Sensor.
    Inoue A; Okino T; Koyama S; Hirose Y
    Sensors (Basel); 2020 May; 20(10):. PubMed ID: 32466348
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Low-noise single-photon avalanche diodes in 0.25 μm high-voltage CMOS technology.
    Hsu FZ; Wu JY; Lin SD
    Opt Lett; 2013 Jan; 38(1):55-7. PubMed ID: 23282836
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Silicon single-photon avalanche diodes with nano-structured light trapping.
    Zang K; Jiang X; Huo Y; Ding X; Morea M; Chen X; Lu CY; Ma J; Zhou M; Xia Z; Yu Z; Kamins TI; Zhang Q; Harris JS
    Nat Commun; 2017 Sep; 8(1):628. PubMed ID: 28931815
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Compact SPAD-Based Pixel Architectures for Time-Resolved Image Sensors.
    Perenzoni M; Pancheri L; Stoppa D
    Sensors (Basel); 2016 May; 16(5):. PubMed ID: 27223284
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Variable-load quenching circuit for single-photon avalanche diodes.
    Tisa S; Guerrieri F; Zappa F
    Opt Express; 2008 Feb; 16(3):2232-44. PubMed ID: 18542303
    [TBL] [Abstract][Full Text] [Related]  

  • 35. A 72 × 60 Angle-Sensitive SPAD Imaging Array for Lens-less FLIM.
    Lee C; Johnson B; Jung T; Molnar A
    Sensors (Basel); 2016 Sep; 16(9):. PubMed ID: 27598170
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Fluorescence-suppressed time-resolved Raman spectroscopy of pharmaceuticals using complementary metal-oxide semiconductor (CMOS) single-photon avalanche diode (SPAD) detector.
    Rojalin T; Kurki L; Laaksonen T; Viitala T; Kostamovaara J; Gordon KC; Galvis L; Wachsmann-Hogiu S; Strachan CJ; Yliperttula M
    Anal Bioanal Chem; 2016 Jan; 408(3):761-74. PubMed ID: 26549117
    [TBL] [Abstract][Full Text] [Related]  

  • 37. New silicon technologies enable high-performance arrays of Single Photon Avalanche Diodes.
    Gulinatti A; Rech I; Maccagnani P; Cova S; Ghioni M
    Proc SPIE Int Soc Opt Eng; 2013 May; 8727():87270M-. PubMed ID: 24353395
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Characterization of a novel avalanche photodiode for single photon detection in VIS-NIR range.
    Stipcević M; Skenderović H; Gracin D
    Opt Express; 2010 Aug; 18(16):17448-59. PubMed ID: 20721130
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Silicon technologies for arrays of Single Photon Avalanche Diodes.
    Gulinatti A; Ceccarelli F; Rech I; Ghioni M
    Proc SPIE Int Soc Opt Eng; 2016 Apr; 9858():. PubMed ID: 27761058
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Note: Fully integrated active quenching circuit achieving 100 MHz count rate with custom technology single photon avalanche diodes.
    Acconcia G; Labanca I; Rech I; Gulinatti A; Ghioni M
    Rev Sci Instrum; 2017 Feb; 88(2):026103. PubMed ID: 28249471
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 16.