These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

147 related articles for article (PubMed ID: 26076004)

  • 1. Potential of Missing Life-Threatening Arrhythmias After Limiting the Use of Cardiac Telemetry.
    Kansara P; Jackson K; Dressler R; Weiner H; Kerzner R; Weintraub WS; Doorey A
    JAMA Intern Med; 2015 Aug; 175(8):1416-8. PubMed ID: 26076004
    [No Abstract]   [Full Text] [Related]  

  • 2. Are the American College of Cardiology/Emergency Cardiac Care (ACC/ECC) guidelines useful in triaging patients to telemetry units?
    Tiongson J; Robin J; Chana A; Shin DD; Gheorghiade M
    Acute Card Care; 2006; 8(3):155-60. PubMed ID: 17012130
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Is telemetry overused? Is it as helpful as thought?
    Henriques-Forsythe MN; Ivonye CC; Jamched U; Kamuguisha LK; Olejeme KA; Onwuanyi AE
    Cleve Clin J Med; 2009 Jun; 76(6):368-72. PubMed ID: 19487558
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effect of an electronic ordering system on adherence to the American College of Cardiology/American Heart Association guidelines for cardiac monitoring.
    Leighton H; Kianfar H; Serynek S; Kerwin T
    Crit Pathw Cardiol; 2013 Mar; 12(1):6-8. PubMed ID: 23411601
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Do children require ECG evaluation and inpatient telemetry after household electrical exposures?
    Chen EH; Sareen A
    Ann Emerg Med; 2007 Jan; 49(1):64-7. PubMed ID: 17141143
    [No Abstract]   [Full Text] [Related]  

  • 6. Update to Practice Standards for Electrocardiographic Monitoring in Hospital Settings: A Scientific Statement From the American Heart Association.
    Sandau KE; Funk M; Auerbach A; Barsness GW; Blum K; Cvach M; Lampert R; May JL; McDaniel GM; Perez MV; Sendelbach S; Sommargren CE; Wang PJ;
    Circulation; 2017 Nov; 136(19):e273-e344. PubMed ID: 28974521
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Ambulatory telemetry arrhythmia monitoring systems.
    Health Devices; 1994 Jul; 23(7):267-97. PubMed ID: 10147306
    [No Abstract]   [Full Text] [Related]  

  • 8. Telemetry monitoring guidelines for efficient and safe delivery of cardiac rhythm monitoring to noncritical hospital inpatients.
    Dhillon SK; Rachko M; Hanon S; Schweitzer P; Bergmann SR
    Crit Pathw Cardiol; 2009 Sep; 8(3):125-6. PubMed ID: 19726933
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Evaluation of Telemetry Utilization on Medical-Surgical Units.
    Phillips J; Polomano RC; Leming-Lee T'; Crutcher TD
    Nurs Clin North Am; 2019 Mar; 54(1):97-114. PubMed ID: 30712547
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A proposal for a T-wave alternans index.
    Madias JE
    J Electrocardiol; 2007; 40(6):479-81. PubMed ID: 17543326
    [No Abstract]   [Full Text] [Related]  

  • 11. Reliability and limitations of automated arrhythmia detection in telemetric monitoring after stroke.
    Kurka N; Bobinger T; Kallmünzer B; Koehn J; Schellinger PD; Schwab S; Köhrmann M
    Stroke; 2015 Feb; 46(2):560-3. PubMed ID: 25538198
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Requirement for cardiac telemetry during intravenous phenytoin infusion: guideline fact or guideline fiction?
    Siebert WJ; McGavigan AD
    Intern Med J; 2013 Jan; 43(1):7-17. PubMed ID: 22947413
    [TBL] [Abstract][Full Text] [Related]  

  • 13. 2012 ACCF/AHA/HRS focused update of the 2008 guidelines for device-based therapy of cardiac rhythm abnormalities: a report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines.
    ; Tracy CM; Epstein AE; Darbar D; DiMarco JP; Dunbar SB; Estes NA; Ferguson TB; Hammill SC; Karasik PE; Link MS; Marine JE; Schoenfeld MH; Shanker AJ; Silka MJ; Stevenson LW; Stevenson WG; Varosy PD; ; Epstein AE; DiMarco JP; Ellenbogen KA; Estes NA; Freedman RA; Gettes LS; Gillinov AM; Gregoratos G; Hammill SC; Hayes DL; Hlatky MA; Newby LK; Page RL; Schoenfeld MH; Silka MJ; Stevenson LW; Sweeney MO; ; Anderson JL; Jacobs AK; Halperin JL; Albert NM; Creager MA; DeMets D; Ettinger SM; Guyton RA; Hochman JS; Kushner FG; Ohman EM; Stevenson W; Yancy CW; ; ; ; ;
    J Thorac Cardiovasc Surg; 2012 Dec; 144(6):e127-45. PubMed ID: 23140976
    [No Abstract]   [Full Text] [Related]  

  • 14. Impact of the American Heart Association scientific statement on screening electrocardiograms and stimulant medications.
    Thomas PE; Carlo WF; Decker JA; Cannon BC; Kertesz NJ; Friedman RA; Kim JJ
    Arch Pediatr Adolesc Med; 2011 Feb; 165(2):166-70. PubMed ID: 21300657
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Guidance section: implementation and effective use of telemetry arrhythmia monitoring systems.
    Health Devices; 1994 Jul; 23(7):298-305. PubMed ID: 10147307
    [No Abstract]   [Full Text] [Related]  

  • 16. American Heart Association/American College of Cardiology Foundation/Heart Rhythm Society scientific statement on noninvasive risk stratification techniques for identifying patients at risk for sudden cardiac death: a scientific statement from the American Heart Association Council on Clinical Cardiology Committee on Electrocardiography and Arrhythmias and Council on Epidemiology and Prevention.
    Goldberger JJ; Cain ME; Hohnloser SH; Kadish AH; Knight BP; Lauer MS; Maron BJ; Page RL; Passman RS; Siscovick D; Siscovick D; Stevenson WG; Zipes DP; ; ;
    Circulation; 2008 Sep; 118(14):1497-1518. PubMed ID: 18833586
    [No Abstract]   [Full Text] [Related]  

  • 17. Cardiovascular nurses' adherence to practice standards in in-hospital telemetry monitoring.
    Fålun N; Oterhals K; Pettersen T; Brørs G; Olsen SS; Norekvål TM;
    Nurs Crit Care; 2020 Jan; 25(1):37-44. PubMed ID: 30969471
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Step-down units and telemetry monitoring: optimizing utilization.
    Health Devices; 1993 Jan; 22(1):25-7. PubMed ID: 8425863
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Frequencies and types of arrhythmias in patients with systemic light-chain amyloidosis with cardiac involvement undergoing stem cell transplantation on telemetry monitoring.
    Goldsmith YB; Liu J; Chou J; Hoffman J; Comenzo RL; Steingart RM
    Am J Cardiol; 2009 Oct; 104(7):990-4. PubMed ID: 19766769
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Association Between Off-site Central Monitoring Using Standardized Cardiac Telemetry and Clinical Outcomes Among Non-Critically Ill Patients.
    Cantillon DJ; Loy M; Burkle A; Pengel S; Brosovich D; Hamilton A; Khot UN; Lindsay BD
    JAMA; 2016 Aug; 316(5):519-24. PubMed ID: 27483066
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.