These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
540 related articles for article (PubMed ID: 26076457)
1. Repeatability of Foveal Measurements Using Spectralis Optical Coherence Tomography Segmentation Software. Ctori I; Huntjens B PLoS One; 2015; 10(6):e0129005. PubMed ID: 26076457 [TBL] [Abstract][Full Text] [Related]
2. Do different spectral domain OCT hardwares measure the same? Comparison of retinal thickness using third-party software. Sander B; Al-Abiji HA; Kofod M; Jørgensen TM Graefes Arch Clin Exp Ophthalmol; 2015 Nov; 253(11):1915-21. PubMed ID: 26067394 [TBL] [Abstract][Full Text] [Related]
3. A novel technique of adjusting segmentation boundary layers to achieve comparability of retinal thickness and volumes between spectral domain and time domain optical coherence tomography. Tan CS; Li KZ; Lim TH Invest Ophthalmol Vis Sci; 2012 Aug; 53(9):5515-9. PubMed ID: 22786905 [TBL] [Abstract][Full Text] [Related]
9. Mathematical analysis of the normal anatomy of the aging fovea. Nesmith B; Gupta A; Strange T; Schaal Y; Schaal S Invest Ophthalmol Vis Sci; 2014 Aug; 55(9):5962-6. PubMed ID: 25168895 [TBL] [Abstract][Full Text] [Related]
10. Automated Retinal Layer Segmentation Using Spectral Domain Optical Coherence Tomography: Evaluation of Inter-Session Repeatability and Agreement between Devices. Terry L; Cassels N; Lu K; Acton JH; Margrain TH; North RV; Fergusson J; White N; Wood A PLoS One; 2016; 11(9):e0162001. PubMed ID: 27588683 [TBL] [Abstract][Full Text] [Related]
11. Optical density filters modeling media opacities cause decreased SD-OCT retinal layer thickness measurements with inter- and intra-individual variation. Darma S; Kok PH; van den Berg TJ; Abràmoff MD; Faber DJ; Hulsman CA; Zantvoord F; Mourits MP; Schlingemann RO; Verbraak FD Acta Ophthalmol; 2015 Jun; 93(4):355-61. PubMed ID: 25487761 [TBL] [Abstract][Full Text] [Related]
12. Analysis of spectral-domain optical coherence tomography measurements in amblyopia: a pilot study. Park KA; Park DY; Oh SY Br J Ophthalmol; 2011 Dec; 95(12):1700-6. PubMed ID: 21427458 [TBL] [Abstract][Full Text] [Related]
13. Clinical relevance of foveal location on retinal nerve fiber layer thickness using the new FoDi software in spectralis optical coherence tomography. Valverde-Megías A; Martinez-de-la-Casa JM; Serrador-García M; Larrosa JM; García-Feijoó J Invest Ophthalmol Vis Sci; 2013 Aug; 54(8):5771-6. PubMed ID: 23908184 [TBL] [Abstract][Full Text] [Related]
14. Predicted and measured retinal nerve fiber layer thickness from time-domain optical coherence tomography compared with spectral-domain optical coherence tomography. Schrems WA; Schrems-Hoesl LM; Bendschneider D; Mardin CY; Laemmer R; Kruse FE; Horn FK JAMA Ophthalmol; 2015 Oct; 133(10):1135-43. PubMed ID: 26225533 [TBL] [Abstract][Full Text] [Related]
15. Diurnal variation of retinal thickness with spectral domain OCT. Read SA; Collins MJ; Alonso-Caneiro D Optom Vis Sci; 2012 May; 89(5):611-9. PubMed ID: 22446718 [TBL] [Abstract][Full Text] [Related]
16. Analysis of spectral-domain optical coherence tomography in preterm children: retinal layer thickness and choroidal thickness profiles. Park KA; Oh SY Invest Ophthalmol Vis Sci; 2012 Oct; 53(11):7201-7. PubMed ID: 23033393 [TBL] [Abstract][Full Text] [Related]
17. Reproducibility and repeatability of Cirrus™ HD-OCT peripapillary retinal nerve fibre layer thickness measurements in young normal subjects. Carpineto P; Nubile M; Agnifili L; Toto L; Aharrh-Gnama A; Mastropasqua R; Di Antonio L; Fasanella V; Mastropasqua A Ophthalmologica; 2012; 227(3):139-45. PubMed ID: 22261709 [TBL] [Abstract][Full Text] [Related]
18. Repeatability and Reproducibility of Axial and Lateral Measurements on Handheld Optical Coherence Tomography Systems Compared with Tabletop System. Chen X; Tai V; McGeehan B; Ying GS; Viehland C; Imperio R; Winter KP; Raynor W; Tran-Viet D; Mangalesh S; Maguire MG; Toth CA; Transl Vis Sci Technol; 2020 Oct; 9(11):25. PubMed ID: 33150050 [TBL] [Abstract][Full Text] [Related]
19. Reproducibility and repeatability of foveal avascular zone measurements in healthy subjects by optical coherence tomography angiography. Carpineto P; Mastropasqua R; Marchini G; Toto L; Di Nicola M; Di Antonio L Br J Ophthalmol; 2016 May; 100(5):671-6. PubMed ID: 26377414 [TBL] [Abstract][Full Text] [Related]