BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

491 related articles for article (PubMed ID: 26076497)

  • 1. Metal-organic framework MIL-101(Cr) as a sorbent of porous membrane-protected micro-solid-phase extraction for the analysis of six phthalate esters from drinking water: a combination of experimental and computational study.
    Wang T; Wang J; Zhang C; Yang Z; Dai X; Cheng M; Hou X
    Analyst; 2015 Aug; 140(15):5308-16. PubMed ID: 26076497
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Graphene nanoplatelets as a highly efficient solid-phase extraction sorbent for determination of phthalate esters in aqueous solution.
    Luo X; Zhang F; Ji S; Yang B; Liang X
    Talanta; 2014 Mar; 120():71-5. PubMed ID: 24468344
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A novel metal-organic framework composite MIL-101(Cr)@GO as an efficient sorbent in dispersive micro-solid phase extraction coupling with UHPLC-MS/MS for the determination of sulfonamides in milk samples.
    Jia X; Zhao P; Ye X; Zhang L; Wang T; Chen Q; Hou X
    Talanta; 2017 Jul; 169():227-238. PubMed ID: 28411816
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Dispersive magnetic solid-phase extraction of phthalate esters from water samples and human plasma based on a nanosorbent composed of MIL-101(Cr) metal-organic framework and magnetite nanoparticles before their determination by GC-MS.
    Dargahi R; Ebrahimzadeh H; Asgharinezhad AA; Hashemzadeh A; Amini MM
    J Sep Sci; 2018 Feb; 41(4):948-957. PubMed ID: 29178577
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Preparation of magnetite/multiwalled carbon nanotubes/metal-organic framework composite for dispersive magnetic micro solid phase extraction of parabens and phthalate esters from water samples and various types of cream for their determination with liquid chromatography.
    Jalilian N; Ebrahimzadeh H; Asgharinezhad AA
    J Chromatogr A; 2019 Dec; 1608():460426. PubMed ID: 31416622
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Vortex-assisted micro-solid-phase extraction followed by low-density solvent based dispersive liquid-liquid microextraction for the fast and efficient determination of phthalate esters in river water samples.
    Guo L; Lee HK
    J Chromatogr A; 2013 Jul; 1300():24-30. PubMed ID: 23374370
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Micro-solid-phase extraction of organochlorine pesticides using porous metal-organic framework MIL-101 as sorbent.
    Huang Z; Lee HK
    J Chromatogr A; 2015 Jul; 1401():9-16. PubMed ID: 25987299
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Magnetic solid-phase extraction based on magnetic carbon particles from coffee grounds for determining phthalic acid esters in plastic bottled water.
    Song NE; Lim MC; Choi SW; Kim DO; Nam TG
    J Food Sci; 2020 Apr; 85(4):1098-1104. PubMed ID: 32147835
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Analysis of trace contamination of phthalate esters in ultrapure water using a modified solid-phase extraction procedure and automated thermal desorption-gas chromatography/mass spectrometry.
    Liu HC; Den W; Chan SF; Kin KT
    J Chromatogr A; 2008 Apr; 1188(2):286-94. PubMed ID: 18342867
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Experimental and molecular docking investigation on metal-organic framework MIL-101(Cr) as a sorbent for vortex assisted dispersive micro-solid-phase extraction of trace 5-nitroimidazole residues in environmental water samples prior to UPLC-MS/MS analysis.
    Lu N; Wang T; Zhao P; Zhang L; Lun X; Zhang X; Hou X
    Anal Bioanal Chem; 2016 Nov; 408(29):8515-8528. PubMed ID: 27722939
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Graphene-dispersive solid-phase extraction of phthalate acid esters from environmental water.
    Wu X; Hong H; Liu X; Guan W; Meng L; Ye Y; Ma Y
    Sci Total Environ; 2013 Feb; 444():224-30. PubMed ID: 23274241
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The metal-organic framework MIL-101(Cr) as efficient adsorbent in a vortex-assisted dispersive solid-phase extraction of imatinib mesylate in rat plasma coupled with ultra-performance liquid chromatography/mass spectrometry: Application to a pharmacokinetic study.
    Qi C; Cai Q; Zhao P; Jia X; Lu N; He L; Hou X
    J Chromatogr A; 2016 Jun; 1449():30-8. PubMed ID: 27139217
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Water stability of zeolite imidazolate framework 8 and application to porous membrane-protected micro-solid-phase extraction of polycyclic aromatic hydrocarbons from environmental water samples.
    Ge D; Lee HK
    J Chromatogr A; 2011 Nov; 1218(47):8490-5. PubMed ID: 22018717
    [TBL] [Abstract][Full Text] [Related]  

  • 14. C8-modified magnetic graphene oxide based solid-phase extraction coupled with dispersive liquid-liquid microextraction for detection of trace phthalate acid esters in water samples.
    Wang R; Ma X; Zhang X; Li X; Li D; Dang Y
    Ecotoxicol Environ Saf; 2019 Apr; 170():789-795. PubMed ID: 30593992
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Determination of 11 Phthalate Esters in Beverages by Magnetic Solid-Phase Extraction Combined with High-Performance Liquid Chromatography.
    Yin S; Yang Y; Yang D; Li Y; Jiang Y; Wu L; Sun C
    J AOAC Int; 2019 Sep; 102(5):1624-1631. PubMed ID: 30823939
    [No Abstract]   [Full Text] [Related]  

  • 16. Magnetic solid-phase extraction based on modified magnetic nanoparticles for the determination of phthalate diesters in water samples.
    Zare Jeddi M; Ahmadkhaniha R; Yunesian M; Rastkari N
    J Chromatogr Sci; 2015 Feb; 53(2):385-91. PubMed ID: 24965039
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A combined experimental/computational study on metal-organic framework MIL-101(Cr) as a SPE sorbent for the determination of sulphonamides in environmental water samples coupling with UPLC-MS/MS.
    Dai X; Jia X; Zhao P; Wang T; Wang J; Huang P; He L; Hou X
    Talanta; 2016 Jul; 154():581-8. PubMed ID: 27154718
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A combination of computational-experimental study on metal-organic frameworks MIL-53(Al) as sorbent for simultaneous determination of estrogens and glucocorticoids in water and urine samples by dispersive micro-solid-phase extraction coupled to UPLC-MS/MS.
    Gao G; Li S; Li S; Wang Y; Zhao P; Zhang X; Hou X
    Talanta; 2018 Apr; 180():358-367. PubMed ID: 29332823
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Polydimethylsiloxane/metal-organic frameworks coated stir bar sorptive extraction coupled to gas chromatography-flame photometric detection for the determination of organophosphorus pesticides in environmental water samples.
    Xiao Z; He M; Chen B; Hu B
    Talanta; 2016 Aug; 156-157():126-133. PubMed ID: 27260444
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Preparation of a chitosan-coated C(18)-functionalized magnetite nanoparticle sorbent for extraction of phthalate ester compounds from environmental water samples.
    Zhang XL; Niu HY; Zhang SX; Cai YQ
    Anal Bioanal Chem; 2010 May; 397(2):791-8. PubMed ID: 20229007
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 25.