  • 1. Response characteristics of esophageal balloon catheters handmade using latex and nonlatex materials.
    Cross TJ; Lalande S; Hyatt RE; Johnson BD
    Physiol Rep; 2015 Jun; 3(6):. PubMed ID: 26077619
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Correcting the dynamic response of a commercial esophageal balloon-catheter.
    Cross TJ; Beck KC; Johnson BD
    J Appl Physiol (1985); 2016 Aug; 121(2):503-11. PubMed ID: 27402558
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Evaluation of the efficacy of a nonlatex condom: results from a randomized, controlled clinical trial.
    Walsh TL; Frezieres RG; Peacock K; Nelson AL; Clark VA; Bernstein L
    Perspect Sex Reprod Health; 2003; 35(2):79-86. PubMed ID: 12729137
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Latex allergy: local hypersensitivity reaction cause by an esophageal catheter in compliance determination].
    Baur X; Chen Z; Korn M; Molkenthin A; Nioduschewski R; Schneider EM
    Pneumologie; 1998 Jan; 52(1):24-5. PubMed ID: 9540367
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Measurements Obtained From Esophageal Balloon Catheters Are Affected by the Esophageal Balloon Filling Volume in Children With ARDS.
    Hotz JC; Sodetani CT; Van Steenbergen J; Khemani RG; Deakers TW; Newth CJ
    Respir Care; 2018 Feb; 63(2):177-186. PubMed ID: 29089460
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Assessing respiratory function depends on mechanical characteristics of balloon catheters.
    Walterspacher S; Isaak L; Guttmann J; Kabitz HJ; Schumann S
    Respir Care; 2014 Sep; 59(9):1345-52. PubMed ID: 24381189
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Nonlatex vs. latex male condoms for contraception: a systematic review of randomized controlled trials.
    Gallo MF; Grimes DA; Schulz KF
    Contraception; 2003 Nov; 68(5):319-26. PubMed ID: 14636934
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Foley Catheter Balloon Rupture and Risk of Free Fragment Formation.
    Lui JL; Shaw NM; Hakam N; Nabavizadeh B; Li KD; Low P; Abbasi B; Breyer BN
    Urology; 2022 Jul; 165():67-71. PubMed ID: 35385776
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The burst catheter balloon: A comparison of fragmentation rates and overinflation burst volumes in Foley catheters with special considerations in SCI.
    Gilbert C; Linsenmeyer TA
    J Spinal Cord Med; 2023 Jul; 46(4):540-545. PubMed ID: 35108173
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Stability and Agreement of a Microtransducer and an Air-Filled Balloon Esophageal Catheter in the Monitoring of Esophageal Pressure.
    Augusto RM; Albuquerque AL; Jaeger T; de Carvalho CR; Caruso P
    Respir Care; 2017 Feb; 62(2):215-221. PubMed ID: 27729399
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Esophageal pressure measurements under different conditions of intrathoracic pressure. An in vitro study of second generation balloon catheters.
    Mojoli F; Chiumello D; Pozzi M; Algieri I; Bianzina S; Luoni S; Volta CA; Braschi A; Brochard L
    Minerva Anestesiol; 2015 Aug; 81(8):855-64. PubMed ID: 25634481
    [TBL] [Abstract][Full Text] [Related]  

  • 12. First plastic condom for men becomes available next year.
    Contracept Technol Update; 1993 Oct; 14(10):156-7. PubMed ID: 12286906
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Carter-Wallace debuts new polyurethane condom in U.S.
    Contracept Technol Update; 1999 Jul; 20(7):73-5. PubMed ID: 12295380
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Pressure measurement characteristics of a micro-transducer and balloon catheters.
    MacAskill W; Hoffman B; Johnson MA; Sharpe GR; Mills DE
    Physiol Rep; 2021 Apr; 9(8):e14831. PubMed ID: 33938126
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Methods for studying intestinal sensitivity and compliance: in vitro studies of balloons and a barostat.
    Toma TP; Zighelboim J; Phillips SF; Talley NJ
    Neurogastroenterol Motil; 1996 Mar; 8(1):19-28. PubMed ID: 8697181
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Tensile set behavior of Foley catheter balloons.
    Joseph R; Ramesh P; Sivakumar R
    J Biomed Mater Res; 1999; 48(1):27-31. PubMed ID: 10029146
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Spermiotoxicity of commercial condoms made from polyurethane, polyisoprene and latex, using domestic ruminants as an experimental animal model.
    Pradiee J; O'Brien E; Esteso MC; Castaño C; Toledano-Díaz A; López-Sebastián A; Santiago-Moreno J
    Andrologia; 2016 May; 48(4):475-80. PubMed ID: 26289632
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The Ideal Use of Catheters in Hypospadias Repair: An Experimental Study.
    Polat H; Gulacti U
    Urol J; 2016 Oct; 13(5):2856-2859. PubMed ID: 27734429
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Management of "consort dermatitis" due to combined allergy: seminal fluid and latex condoms.
    Fisher AA
    Cutis; 1994 Aug; 54(2):66-7. PubMed ID: 7956337
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A comparison of dynamic and static testing of latex and nonlatex orthodontic elastics.
    Kersey ML; Glover KE; Heo G; Raboud D; Major PW
    Angle Orthod; 2003 Apr; 73(2):181-6. PubMed ID: 12725375
    [TBL] [Abstract][Full Text] [Related]  