BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

142 related articles for article (PubMed ID: 26087908)

  • 21. Initial results for patient setup verification using transperineal ultrasound and cone beam CT in external beam radiation therapy of prostate cancer.
    Richter A; Polat B; Lawrenz I; Weick S; Sauer O; Flentje M; Mantel F
    Radiat Oncol; 2016 Nov; 11(1):147. PubMed ID: 27825386
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Cervix Motion in 50 Cervical Cancer Patients Assessed by Daily Cone Beam Computed Tomographic Imaging of a New Type of Marker.
    Langerak T; Mens JW; Quint S; Bondar L; Heijkoop S; Heijmen B; Hoogeman M
    Int J Radiat Oncol Biol Phys; 2015 Nov; 93(3):532-9. PubMed ID: 26460995
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Evaluation of multiple image-based modalities for image-guided radiation therapy (IGRT) of prostate carcinoma: a prospective study.
    Mayyas E; Chetty IJ; Chetvertkov M; Wen N; Neicu T; Nurushev T; Ren L; Lu M; Stricker H; Pradhan D; Movsas B; Elshaikh MA
    Med Phys; 2013 Apr; 40(4):041707. PubMed ID: 23556877
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Cone beam CT (CBCT) evaluation of inter- and intra-fraction motion for patients undergoing brain radiotherapy immobilized using a commercial thermoplastic mask on a robotic couch.
    Lightstone AW; Tsao M; Baran PS; Chan G; Pang G; Ma L; Lochray F; Sahgal A
    Technol Cancer Res Treat; 2012 Jun; 11(3):203-9. PubMed ID: 22376132
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Positioning reproducibility with and without rotational corrections for 2 head and neck immobilization systems.
    Courneyea L; Mullins J; Howard M; Foote R; Garces Y; Ma D; Beltran C; Brinkmann D; Pafundi D
    Pract Radiat Oncol; 2015; 5(6):e575-81. PubMed ID: 26169225
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Effect of immobilization and performance status on intrafraction motion for stereotactic lung radiotherapy: analysis of 133 patients.
    Li W; Purdie TG; Taremi M; Fung S; Brade A; Cho BC; Hope A; Sun A; Jaffray DA; Bezjak A; Bissonnette JP
    Int J Radiat Oncol Biol Phys; 2011 Dec; 81(5):1568-75. PubMed ID: 21075559
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Towards clinical implementation of ultrafast combined kV-MV CBCT for IGRT of lung cancer : Evaluation of registration accuracy based on phantom study.
    Arns A; Blessing M; Fleckenstein J; Stsepankou D; Boda-Heggemann J; Simeonova-Chergou A; Hesser J; Lohr F; Wenz F; Wertz H
    Strahlenther Onkol; 2016 May; 192(5):312-21. PubMed ID: 26864049
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Generic method for automatic bladder segmentation on cone beam CT using a patient-specific bladder shape model.
    van de Schoot AJ; Schooneveldt G; Wognum S; Hoogeman MS; Chai X; Stalpers LJ; Rasch CR; Bel A
    Med Phys; 2014 Mar; 41(3):031707. PubMed ID: 24593711
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Accuracy of surface registration compared to conventional volumetric registration in patient positioning for head-and-neck radiotherapy: a simulation study using patient data.
    Kim Y; Li R; Na YH; Lee R; Xing L
    Med Phys; 2014 Dec; 41(12):121701. PubMed ID: 25471948
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Comparison of initial patient setup accuracy between surface imaging and three point localization: A retrospective analysis.
    Stanley DN; McConnell KA; Kirby N; Gutiérrez AN; Papanikolaou N; Rasmussen K
    J Appl Clin Med Phys; 2017 Nov; 18(6):58-61. PubMed ID: 28901684
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Optical Surface Scanning for Patient Positioning in Radiation Therapy: A Prospective Analysis of 1902 Fractions.
    Carl G; Reitz D; Schönecker S; Pazos M; Freislederer P; Reiner M; Alongi F; Niyazi M; Ganswindt U; Belka C; Corradini S
    Technol Cancer Res Treat; 2018 Jan; 17():1533033818806002. PubMed ID: 30453842
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Detection of intrafractional tumour position error in radiotherapy utilizing cone beam computed tomography.
    Xu F; Wang J; Bai S; Li Y; Shen Y; Zhong R; Jiang X; Xu Q
    Radiother Oncol; 2008 Dec; 89(3):311-9. PubMed ID: 18774195
    [TBL] [Abstract][Full Text] [Related]  

  • 33. [Primary study of the threatening of unfixed planning of image guided radiotherapy to the volume margin of neck tumor].
    Wu Y; Zhong R; Zhang Y; Liu Z; Li G; Bai S
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2013 Jun; 30(3):503-7. PubMed ID: 23865308
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Assessment of set-up variability during deep inspiration breath hold radiotherapy for breast cancer patients by 3D-surface imaging.
    Betgen A; Alderliesten T; Sonke JJ; van Vliet-Vroegindeweij C; Bartelink H; Remeijer P
    Radiother Oncol; 2013 Feb; 106(2):225-30. PubMed ID: 23414819
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Comparison of kilovoltage cone-beam computed tomography with megavoltage projection pairs for paraspinal radiosurgery patient alignment and position verification.
    Kriminski SA; Lovelock DM; Seshan VE; Ali I; Munro P; Amols HI; Fuks Z; Bilsky M; Yamada Y
    Int J Radiat Oncol Biol Phys; 2008 Aug; 71(5):1572-80. PubMed ID: 18539405
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Development of CBCT-based prostate setup correction strategies and impact of rectal distension.
    Boydev C; Taleb-Ahmed A; Derraz F; Peyrodie L; Thiran JP; Pasquier D
    Radiat Oncol; 2015 Apr; 10():83. PubMed ID: 25890308
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Surface-guided positioning eliminates the need for skin markers in radiotherapy of right sided breast cancer: A single center randomized crossover trial.
    Svestad JG; Heydari M; Mikalsen SG; Flote VG; Nordby F; Hellebust TP
    Radiother Oncol; 2022 Dec; 177():46-52. PubMed ID: 36309152
    [TBL] [Abstract][Full Text] [Related]  

  • 38. [Application of image-guided radiotherapy in external beam radiation of cancer patients].
    Major T; Agoston P; Jorgo K; Polgár C
    Magy Onkol; 2012 Dec; 56(4):258-65. PubMed ID: 23236596
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Prospective feasibility analysis of a novel off-line approach for MR-guided radiotherapy.
    Bostel T; Pfaffenberger A; Delorme S; Dreher C; Echner G; Haering P; Lang C; Splinter M; Laun F; Müller M; Jäkel O; Debus J; Huber PE; Sterzing F; Nicolay NH
    Strahlenther Onkol; 2018 May; 194(5):425-434. PubMed ID: 29349601
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Setup reproducibility for thoracic and upper gastrointestinal radiation therapy: Influence of immobilization method and on-line cone-beam CT guidance.
    Li W; Moseley DJ; Bissonnette JP; Purdie TG; Bezjak A; Jaffray DA
    Med Dosim; 2010; 35(4):287-96. PubMed ID: 19962877
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.