198 related articles for article (PubMed ID: 26092666)
1. Three-year haemodynamic performance of the St Jude Trifecta bioprosthesis.
Ruggieri VG; Anselmi A; Chabanne C; Lelong B; Flecher E; Verhoye JP; Leguerrier A
Eur J Cardiothorac Surg; 2016 Mar; 49(3):972-7. PubMed ID: 26092666
[TBL] [Abstract][Full Text] [Related]
2. Early haemodynamic performance of a latest generation supra-annular aortic bioprosthesis: experience from a large single-centre series.
Deutsch MA; Prinzing A; Fiegl K; Wottke M; Badiu CC; Krane M; Goppel G; Bleiziffer S; Guenzinger R; Lange R
Eur J Cardiothorac Surg; 2016 Jun; 49(6):1691-8. PubMed ID: 26656235
[TBL] [Abstract][Full Text] [Related]
3. Comprehensive hemodynamic performance and frequency of patient-prosthesis mismatch of the St. Jude Medical Trifecta bioprosthetic aortic valve.
Yadlapati A; Diep J; Barnes MJ; Grogan T; Bethencourt DM; Vorobiof G
J Heart Valve Dis; 2014 Jul; 23(4):516-23. PubMed ID: 25803979
[TBL] [Abstract][Full Text] [Related]
4. The St Jude Medical Trifecta aortic pericardial valve: results from a global, multicenter, prospective clinical study.
Bavaria JE; Desai ND; Cheung A; Petracek MR; Groh MA; Borger MA; Schaff HV
J Thorac Cardiovasc Surg; 2014 Feb; 147(2):590-7. PubMed ID: 23477687
[TBL] [Abstract][Full Text] [Related]
5. Comprehensive hemodynamic comparison and frequency of patient-prosthesis mismatch between the St. Jude Medical Trifecta and Epic Bioprosthetic aortic valves.
Yadlapati A; Diep J; Barnes M; Grogan T; Bethencourt DM; Vorobiof G
J Am Soc Echocardiogr; 2014 Jun; 27(6):581-9. PubMed ID: 24534651
[TBL] [Abstract][Full Text] [Related]
6. Haemodynamic performance of the small supra-annular Trifecta bioprosthesis: results from a French multicentre study.
Fouquet O; Flecher E; Nzomvuama A; Remadi JP; Bière L; Donal E; Levy F; Dalmayrac E; Szymanski C; Leguerrier A; Tribouilloy C
Interact Cardiovasc Thorac Surg; 2016 Apr; 22(4):439-44. PubMed ID: 27002012
[TBL] [Abstract][Full Text] [Related]
7. The TRIBECA study: (TRI)fecta (B)ioprosthesis (E)valuation versus (C)arpentier Magna-Ease in (A)ortic position.
Colli A; Marchetto G; Salizzoni S; Rinaldi M; Di Marco L; Pacini D; Di Bartolomeo R; Nicolini F; Gherli T; Agrifoglio M; Borghetti V; Khoury G; De Paolis M; Zoffoli G; Mangino D; Amorim MJ; Manzan E; Zucchetta F; Balduzzi S; Gerosa G
Eur J Cardiothorac Surg; 2016 Feb; 49(2):478-85. PubMed ID: 25769464
[TBL] [Abstract][Full Text] [Related]
8. Early hemodynamic evaluation of Trifecta and Freestyle bioprostheses in patients with a small aortic root: preliminary results from a prospective randomized study.
Tasca G; Stefano A; Giannico F; Lobiati E; Riva B; Galanti A; Triggiani M; Gamba A
J Heart Valve Dis; 2014 Sep; 23(5):633-41. PubMed ID: 25799714
[TBL] [Abstract][Full Text] [Related]
9. St. Jude Medical Trifecta™ aortic valve perioperative performance in 200 patients.
Permanyer E; Estigarribia AJ; Ysasi A; Herrero E; Semper O; Llorens R
Interact Cardiovasc Thorac Surg; 2013 Oct; 17(4):669-72. PubMed ID: 23825161
[TBL] [Abstract][Full Text] [Related]
10. Hemodynamic performance during exercise of the new St. Jude Trifecta aortic bioprosthesis: results from a French multicenter study.
Levy F; Donal E; Bière L; Szymanski C; Remadi JP; Flécher E; Fouquet O; Leguerrier A; Tribouilloy C
J Am Soc Echocardiogr; 2014 Jun; 27(6):590-7. PubMed ID: 24656322
[TBL] [Abstract][Full Text] [Related]
11. Clinical and echocardiographic outcomes after implantation of the Trifecta aortic bioprosthesis: an initial single-centre experience.
Dell'Aquila AM; Schlarb D; Schneider SR; Sindermann JR; Hoffmeier A; Kaleschke G; Martens S; Rukosujew A
Interact Cardiovasc Thorac Surg; 2013 Feb; 16(2):112-5. PubMed ID: 23159508
[TBL] [Abstract][Full Text] [Related]
12. Comparison of early haemodynamics of 19-mm aortic valve bioprostheses in patients with a small aortic annulus.
Domoto S; Niinami H; Uwabe K; Koike H; Tabata M; Morita K; Kambe M; Iguchi A
Interact Cardiovasc Thorac Surg; 2016 Jan; 22(1):19-25. PubMed ID: 26467641
[TBL] [Abstract][Full Text] [Related]
13. Absence of prosthesis-patient mismatch with the new generation of Edwards stented aortic bioprosthesis.
Wyss TR; Bigler M; Stalder M; Englberger L; Aymard T; Kadner A; Carrel TP
Interact Cardiovasc Thorac Surg; 2010 Jun; 10(6):884-7; discussion 887-8. PubMed ID: 20233807
[TBL] [Abstract][Full Text] [Related]
14. Suture technique does not affect hemodynamic performance of the small supra-annular Trifecta bioprosthesis.
Ugur M; Byrne JG; Bavaria JE; Cheung A; Petracek M; Groh MA; Suri RM; Borger MA; Schaff HV
J Thorac Cardiovasc Surg; 2014 Oct; 148(4):1347-51. PubMed ID: 24518226
[TBL] [Abstract][Full Text] [Related]
15. Trifecta has lower gradient and less prosthesis-patient mismatch than Mosaic Ultra in the aortic position: A prospective randomized study.
Braathen B; Husebye T; Lunde IG; Tønnessen T
J Thorac Cardiovasc Surg; 2019 Oct; 158(4):1032-1039. PubMed ID: 30635187
[TBL] [Abstract][Full Text] [Related]
16. Randomized comparison of exercise haemodynamics of Freestyle, Magna Ease and Trifecta bioprostheses after aortic valve replacement for severe aortic stenosis.
Bach DS; Patel HJ; Kolias TJ; Deeb GM
Eur J Cardiothorac Surg; 2016 Aug; 50(2):361-7. PubMed ID: 26819292
[TBL] [Abstract][Full Text] [Related]
17. Comparison of early hemodynamic performance of 3 aortic valve bioprostheses.
Ugur M; Suri RM; Daly RC; Dearani JA; Park SJ; Joyce LD; Burkhart HM; Greason KL; Schaff HV
J Thorac Cardiovasc Surg; 2014 Nov; 148(5):1940-6. PubMed ID: 24530199
[TBL] [Abstract][Full Text] [Related]
18. St. Jude Medical Trifecta aortic valve: results from a prospective regional multicentre registry.
Mariscalco G; Mariani S; Bichi S; Biondi A; Blasio A; Borsani P; Corti F; De Chiara B; Gherli R; Leva C; Russo CF; Tasca G; Vanelli P; Alfieri O; Antona C; Di Credico G; Esposito G; Gamba A; Martinelli L; Menicanti L; Paolini G; Beghi C
J Cardiothorac Surg; 2015 Nov; 10():169. PubMed ID: 26589286
[TBL] [Abstract][Full Text] [Related]
19. The new St Jude Trifecta versus Carpentier-Edwards Perimount Magna and Magna Ease aortic bioprosthesis: is there a hemodynamic superiority?
Wendt D; Thielmann M; Plicht B; Aßmann J; Price V; Neuhäuser M; Jakob H
J Thorac Cardiovasc Surg; 2014 May; 147(5):1553-60. PubMed ID: 23870159
[TBL] [Abstract][Full Text] [Related]
20. Left ventricular mass regression is independent of gradient drop and effective orifice area after aortic valve replacement with a porcine bioprosthesis.
Sádaba JR; Herregods MC; Bogaert J; Harringer W; Gerosa G
J Heart Valve Dis; 2012 Nov; 21(6):788-94. PubMed ID: 23409363
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]