BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

262 related articles for article (PubMed ID: 26099763)

  • 1. Electromagnetic needle tracking during simulated right internal jugular cannulation.
    Faulke DJ; Hall TH; Nixon C
    Anaesth Intensive Care; 2015 Jul; 43(4):497-502. PubMed ID: 26099763
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Randomized comparison of three transducer orientation approaches for ultrasound guided internal jugular venous cannulation.
    Batllori M; Urra M; Uriarte E; Romero C; Pueyo J; López-Olaondo L; Cambra K; Ibáñez B
    Br J Anaesth; 2016 Mar; 116(3):370-6. PubMed ID: 26705350
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Ultrasound-guided internal jugular vein access: comparison between short axis and long axis techniques.
    Tammam TF; El-Shafey EM; Tammam HF
    Saudi J Kidney Dis Transpl; 2013 Jul; 24(4):707-13. PubMed ID: 23816718
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Ultrasound evaluation of the anatomical characteristics of the internal jugular vein and carotid artery--facilitation of internal jugular vein cannulation.
    Sibai AN; Loutfi E; Itani M; Baraka A
    Middle East J Anaesthesiol; 2008 Oct; 19(6):1305-20. PubMed ID: 18942245
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A randomized crossover study comparing a novel needle guidance technology for simulated internal jugular vein cannulation.
    Auyong DB; Yuan SC; Rymer AN; Green CL; Hanson NA
    Anesthesiology; 2015 Sep; 123(3):535-41. PubMed ID: 26154184
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Internal Jugular Vein Cannulation Using a 3-Dimensional Ultrasound Probe in Patients Undergoing Cardiac Surgery: Comparison Between Biplane View and Short-Axis View.
    Panidapu N; Babu S; Koshy T; Sukesan S; Dash PK; Panicker VT
    J Cardiothorac Vasc Anesth; 2021 Jan; 35(1):91-97. PubMed ID: 32888793
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Simulated internal jugular vein cannulation using a needle-guiding device.
    Kim JH; Park JH; Cho J; Kong TY; Lee JH; Beom JH; Joo YS; Ko DR; Chung HS
    Am J Emerg Med; 2018 Nov; 36(11):1931-1936. PubMed ID: 29467087
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Optimal head rotation and puncture site for internal jugular vein cannulation after laryngeal mask airway insertion.
    Kim WH; Gwak MS; Choi SJ; Song SH; Kim MH
    Singapore Med J; 2015 Aug; 56(8):472-8. PubMed ID: 25902718
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The "medial-oblique" approach to ultrasound-guided central venous cannulation--maximize the view, minimize the risk.
    Dilisio R; Mittnacht AJ
    J Cardiothorac Vasc Anesth; 2012 Dec; 26(6):982-4. PubMed ID: 22683157
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Is long-axis view superior to short-axis view in ultrasound-guided central venous catheterization?
    Vogel JA; Haukoos JS; Erickson CL; Liao MM; Theoret J; Sanz GE; Kendall J
    Crit Care Med; 2015 Apr; 43(4):832-9. PubMed ID: 25517477
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of three techniques for internal jugular vein cannulation in infants.
    Verghese ST; McGill WA; Patel RI; Sell JE; Midgley FM; Ruttimann UE
    Paediatr Anaesth; 2000; 10(5):505-11. PubMed ID: 11012954
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effect of the bevel direction of puncture needle on success rate and complications during internal jugular vein catheterization.
    Lim T; Ryu HG; Jung CW; Jeon Y; Bahk JH
    Crit Care Med; 2012 Feb; 40(2):491-4. PubMed ID: 21983370
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A randomized controlled clinical trial of real-time needle-guided ultrasound for internal jugular venous cannulation in a large university anesthesia department.
    Augoustides JG; Horak J; Ochroch AE; Vernick WJ; Gambone AJ; Weiner J; Pinchasik D; Kowalchuk D; Savino JS; Jobes DR
    J Cardiothorac Vasc Anesth; 2005 Jun; 19(3):310-5. PubMed ID: 16130056
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparative Sonoanatomy of Classic "Short Axis" Probe Position with a Novel "Medial-oblique" Probe Position for Ultrasound-guided Internal Jugular Vein Cannulation: A Crossover Study.
    Baidya DK; Chandralekha ; Darlong V; Pandey R; Goswami D; Maitra S
    J Emerg Med; 2015 May; 48(5):590-6. PubMed ID: 25630474
    [TBL] [Abstract][Full Text] [Related]  

  • 15. An Alternate In-Plane Technique of Ultrasound-Guided Internal Jugular Vein Cannulation.
    Aithal G; Muthuswamy G; Latif Z; Bhaskaran V; Haji Sani HS; Shindhe S; Manap NBA; Vadaje KS; Dato Paduka Buntar WS; Daiwajna RG
    J Emerg Med; 2019 Dec; 57(6):852-858. PubMed ID: 31635927
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Ultrasound monitoring in cannulation of the internal jugular vein: anatomic and technical considerations.
    Docktor B; So CB; Saliken JC; Gray RR
    Can Assoc Radiol J; 1996 Jun; 47(3):195-201. PubMed ID: 8640417
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A prospective, randomised, comparative study to evaluate long axis, short axis and medial oblique axis approach for ultrasound-guided internal jugular vein cannulation.
    Lal J; Bhardwaj M; Verma M; Bansal T
    Indian J Anaesth; 2020 Mar; 64(3):193-198. PubMed ID: 32346165
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Differences in anatomical relationship between vertebral artery and internal jugular vein in children and adults measured by ultrasonography.
    Matsushita K; Yamaura K; Karashima Y; Akiyoshi K; Hoka S
    J Clin Monit Comput; 2016 Apr; 30(2):221-5. PubMed ID: 26018456
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Long versus short axis ultrasound guided approach for internal jugular vein cannulation: a prospective randomised controlled trial.
    Chittoodan S; Breen D; O'Donnell BD; Iohom G
    Med Ultrason; 2011 Mar; 13(1):21-5. PubMed ID: 21390339
    [TBL] [Abstract][Full Text] [Related]  

  • 20. An unseen danger: frequency of posterior vessel wall penetration by needles during attempts to place internal jugular vein central catheters using ultrasound guidance.
    Blaivas M; Adhikari S
    Crit Care Med; 2009 Aug; 37(8):2345-9; quiz 2359. PubMed ID: 19531950
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 14.