209 related articles for article (PubMed ID: 26103481)
1. Comparison between two different algorithms used for pretreatment QA via aSi portal images.
Merheb C; Chevillard C; Ksouri W; Fawzi M; Bollet M; Toledano A
J Appl Clin Med Phys; 2015 May; 16(3):5202. PubMed ID: 26103481
[TBL] [Abstract][Full Text] [Related]
2. Evaluation of an aSi-EPID with flattening filter free beams: applicability to the GLAaS algorithm for portal dosimetry and first experience for pretreatment QA of RapidArc.
Nicolini G; Clivio A; Vanetti E; Krauss H; Fenoglietto P; Cozzi L; Fogliata A
Med Phys; 2013 Nov; 40(11):111719. PubMed ID: 24320427
[TBL] [Abstract][Full Text] [Related]
3. Pixel response-based EPID dosimetry for patient specific QA.
Han B; Ding A; Lu M; Xing L
J Appl Clin Med Phys; 2017 Jan; 18(1):9-17. PubMed ID: 28291939
[TBL] [Abstract][Full Text] [Related]
4. Twin machines validation for VMAT treatments using electronic portal-imaging device: a multicenter study.
Fenoglietto P; Khodri M; Nguyen D; Josserand-Pietri F; Aillères N
Radiat Oncol; 2016 Jan; 11():2. PubMed ID: 26762179
[TBL] [Abstract][Full Text] [Related]
5. EPID-based dosimetry to verify IMRT planar dose distribution for the aS1200 EPID and FFF beams.
Miri N; Keller P; Zwan BJ; Greer P
J Appl Clin Med Phys; 2016 Nov; 17(6):292-304. PubMed ID: 27929502
[TBL] [Abstract][Full Text] [Related]
6. Development of an accurate EPID-based output measurement and dosimetric verification tool for electron beam therapy.
Ding A; Xing L; Han B
Med Phys; 2015 Jul; 42(7):4190-8. PubMed ID: 26133618
[TBL] [Abstract][Full Text] [Related]
7. Anatomy-based, patient-specific VMAT QA using EPID or MLC log files.
Defoor DL; Vazquez-Quino LA; Mavroidis P; Papanikolaou N; Stathakis S
J Appl Clin Med Phys; 2015 May; 16(3):5283. PubMed ID: 26103490
[TBL] [Abstract][Full Text] [Related]
8. A portal dosimetry dose prediction method based on collapsed cone algorithm using the clinical beam model.
Martínez Ortega J; Gómez González N; Castro Tejero P; Pinto Monedero M; Tolani NB; Núñez Martín L; Sánchez Montero R
Med Phys; 2017 Jan; 44(1):333-341. PubMed ID: 28102946
[TBL] [Abstract][Full Text] [Related]
9. The GLAaS algorithm for portal dosimetry and quality assurance of RapidArc, an intensity modulated rotational therapy.
Nicolini G; Vanetti E; Clivio A; Fogliata A; Korreman S; Bocanek J; Cozzi L
Radiat Oncol; 2008 Sep; 3():24. PubMed ID: 18782447
[TBL] [Abstract][Full Text] [Related]
10. Development and clinical evaluation of an ionization chamber array with 3.5 mm pixel pitch for quality assurance in advanced radiotherapy techniques.
Togno M; Wilkens JJ; Menichelli D; Oechsner M; Perez-Andujar A; Morin O
Med Phys; 2016 May; 43(5):2283. PubMed ID: 27147340
[TBL] [Abstract][Full Text] [Related]
11. An empirical model of electronic portal imager response implemented within a commercial treatment planning system for verification of intensity-modulated radiation therapy fields.
Khan RFH; Ostapiak OZ; Szabo JJ
J Appl Clin Med Phys; 2008 Nov; 9(4):135-150. PubMed ID: 19020485
[TBL] [Abstract][Full Text] [Related]
12. Initial application of a geometric QA tool for integrated MV and kV imaging systems on three image guided radiotherapy systems.
Mao W; Speiser M; Medin P; Papiez L; Solberg T; Xing L
Med Phys; 2011 May; 38(5):2335-41. PubMed ID: 21776767
[TBL] [Abstract][Full Text] [Related]
13. Normalize the response of EPID in pursuit of linear accelerator dosimetry standardization.
Cai B; Goddu SM; Yaddanapudi S; Caruthers D; Wen J; Noel C; Mutic S; Sun B
J Appl Clin Med Phys; 2018 Jan; 19(1):73-85. PubMed ID: 29125224
[TBL] [Abstract][Full Text] [Related]
14. Volumetric-modulated arc therapy: effective and efficient end-to-end patient-specific quality assurance.
O'Daniel J; Das S; Wu QJ; Yin FF
Int J Radiat Oncol Biol Phys; 2012 Apr; 82(5):1567-74. PubMed ID: 21470797
[TBL] [Abstract][Full Text] [Related]
15. Detection and correction for EPID and gantry sag during arc delivery using cine EPID imaging.
Rowshanfarzad P; Sabet M; O'Connor DJ; McCowan PM; McCurdy BM; Greer PB
Med Phys; 2012 Feb; 39(2):623-35. PubMed ID: 22320771
[TBL] [Abstract][Full Text] [Related]
16. Commissioning of portal dosimetry using a novel method for flattening filter-free photon beam in a nontrue beam linear accelerator.
Gandhi A; Vellaiyan S; Subramanian VS; Shanmugam T; Murugesan K; Subramanian K
J Cancer Res Ther; 2019; 15(1):223-230. PubMed ID: 30880782
[TBL] [Abstract][Full Text] [Related]
17. In aqua vivo EPID dosimetry.
Wendling M; McDermott LN; Mans A; Olaciregui-Ruiz Í; Pecharromán-Gallego R; Sonke JJ; Stroom J; van Herk M; Mijnheer BJ
Med Phys; 2012 Jan; 39(1):367-77. PubMed ID: 22225306
[TBL] [Abstract][Full Text] [Related]
18. Development and implementation of EPID-based quality assurance tests for the small animal radiation research platform (SARRP).
Anvari A; Poirier Y; Sawant A
Med Phys; 2018 Jul; 45(7):3246-3257. PubMed ID: 29704440
[TBL] [Abstract][Full Text] [Related]
19. Clinical practice and evaluation of electronic portal imaging device for VMAT quality assurance.
Huang YC; Yeh CY; Yeh JH; Lo CJ; Tsai PF; Hung CH; Tsai CS; Chen CY
Med Dosim; 2013; 38(1):35-41. PubMed ID: 22854426
[TBL] [Abstract][Full Text] [Related]
20. Testing the GlaaS algorithm for dose measurements on low- and high-energy photon beams using an amorphous silicon portal imager.
Nicolini G; Fogliata A; Vanetti E; Clivio A; Vetterli D; Cozzi L
Med Phys; 2008 Feb; 35(2):464-72. PubMed ID: 18383666
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]