354 related articles for article (PubMed ID: 26108232)
1. The collapsed cone algorithm for (192)Ir dosimetry using phantom-size adaptive multiple-scatter point kernels.
Tedgren ÅC; Plamondon M; Beaulieu L
Phys Med Biol; 2015 Jul; 60(13):5313-23. PubMed ID: 26108232
[TBL] [Abstract][Full Text] [Related]
2. A generic high-dose rate (192)Ir brachytherapy source for evaluation of model-based dose calculations beyond the TG-43 formalism.
Ballester F; Carlsson Tedgren Å; Granero D; Haworth A; Mourtada F; Fonseca GP; Zourari K; Papagiannis P; Rivard MJ; Siebert FA; Sloboda RS; Smith RL; Thomson RM; Verhaegen F; Vijande J; Ma Y; Beaulieu L
Med Phys; 2015 Jun; 42(6):3048-61. PubMed ID: 26127057
[TBL] [Abstract][Full Text] [Related]
3. Performance evaluation of a collapsed cone dose calculation algorithm for HDR Ir-192 of APBI treatments.
Terribilini D; Vitzthum V; Volken W; Frei D; Loessl K; van Veelen B; Manser P; Fix MK
Med Phys; 2017 Oct; 44(10):5475-5485. PubMed ID: 28750134
[TBL] [Abstract][Full Text] [Related]
4. A CT-based analytical dose calculation method for HDR 192Ir brachytherapy.
Poon E; Verhaegen F
Med Phys; 2009 Sep; 36(9):3982-94. PubMed ID: 19810471
[TBL] [Abstract][Full Text] [Related]
5. Patient-specific Monte Carlo-based dose-kernel approach for inverse planning in afterloading brachytherapy.
D'Amours M; Pouliot J; Dagnault A; Verhaegen F; Beaulieu L
Int J Radiat Oncol Biol Phys; 2011 Dec; 81(5):1582-9. PubMed ID: 21075547
[TBL] [Abstract][Full Text] [Related]
6. A dosimetric comparison of 169Yb and 192Ir for HDR brachytherapy of the breast, accounting for the effect of finite patient dimensions and tissue inhomogeneities.
Lymperopoulou G; Papagiannis P; Angelopoulos A; Karaiskos P; Georgiou E; Baltas D
Med Phys; 2006 Dec; 33(12):4583-9. PubMed ID: 17278810
[TBL] [Abstract][Full Text] [Related]
7. Phantom size in brachytherapy source dosimetric studies.
Pérez-Calatayud J; Granero D; Ballester F
Med Phys; 2004 Jul; 31(7):2075-81. PubMed ID: 15305460
[TBL] [Abstract][Full Text] [Related]
8. A generic TG-186 shielded applicator for commissioning model-based dose calculation algorithms for high-dose-rate
Ma Y; Vijande J; Ballester F; Tedgren ÅC; Granero D; Haworth A; Mourtada F; Fonseca GP; Zourari K; Papagiannis P; Rivard MJ; Siebert FA; Sloboda RS; Smith R; Chamberland MJP; Thomson RM; Verhaegen F; Beaulieu L
Med Phys; 2017 Nov; 44(11):5961-5976. PubMed ID: 28722180
[TBL] [Abstract][Full Text] [Related]
9. Dosimetry of oblique tangential photon beams calculated by superposition/convolution algorithms: a Monte Carlo evaluation.
Chow JC; Jiang R; Leung MK
J Appl Clin Med Phys; 2010 Nov; 12(1):3424. PubMed ID: 21330989
[TBL] [Abstract][Full Text] [Related]
10. Dosimetric characterization of round HDR 192Ir accuboost applicators for breast brachytherapy.
Rivard MJ; Melhus CS; Wazer DE; Bricault RJ
Med Phys; 2009 Nov; 36(11):5027-32. PubMed ID: 19994513
[TBL] [Abstract][Full Text] [Related]
11. Brachytherapy source characterization for improved dose calculations using primary and scatter dose separation.
Russell KR; Tedgren AK; Ahnesjö A
Med Phys; 2005 Sep; 32(9):2739-52. PubMed ID: 16266087
[TBL] [Abstract][Full Text] [Related]
12. Development of a scatter correction technique and its application to HDR 192Ir multicatheter breast brachytherapy.
Poon E; Verhaegen F
Med Phys; 2009 Aug; 36(8):3703-13. PubMed ID: 19746803
[TBL] [Abstract][Full Text] [Related]
13. Influence of phantom material and dimensions on experimental 192Ir dosimetry.
Carlsson Tedgren A; Carlsson GA
Med Phys; 2009 Jun; 36(6):2228-35. PubMed ID: 19610312
[TBL] [Abstract][Full Text] [Related]
14. A BrachyPhantom for verification of dose calculation of HDR brachytherapy planning system.
Austerlitz C; Campos CA
Med Phys; 2013 Nov; 40(11):112103. PubMed ID: 24320456
[TBL] [Abstract][Full Text] [Related]
15. Optimization of the computational efficiency of a 3D, collapsed cone dose calculation algorithm for brachytherapy.
Carlsson Tedgren A; Ahnesjö A
Med Phys; 2008 Apr; 35(4):1611-8. PubMed ID: 18491555
[TBL] [Abstract][Full Text] [Related]
16. Evaluating the Application of Tissue-Specific Dose Kernels Instead of Water Dose Kernels in Internal Dosimetry: A Monte Carlo Study.
Khazaee Moghadam M; Kamali Asl A; Geramifar P; Zaidi H
Cancer Biother Radiopharm; 2016 Dec; 31(10):367-379. PubMed ID: 27996311
[TBL] [Abstract][Full Text] [Related]
17. The effect of patient inhomogeneities in oesophageal 192Ir HDR brachytherapy: a Monte Carlo and analytical dosimetry study.
Anagnostopoulos G; Baltas D; Pantelis E; Papagiannis P; Sakelliou L
Phys Med Biol; 2004 Jun; 49(12):2675-85. PubMed ID: 15272681
[TBL] [Abstract][Full Text] [Related]
18. Development of a phantom to validate high-dose-rate brachytherapy treatment planning systems with heterogeneous algorithms.
Moura ES; Micka JA; Hammer CG; Culberson WS; DeWerd LA; Rostelato ME; Zeituni CA
Med Phys; 2015 Apr; 42(4):1566-74. PubMed ID: 25832047
[TBL] [Abstract][Full Text] [Related]
19. Dosimetric accuracy of a deterministic radiation transport based (192)Ir brachytherapy treatment planning system. Part III. Comparison to Monte Carlo simulation in voxelized anatomical computational models.
Zourari K; Pantelis E; Moutsatsos A; Sakelliou L; Georgiou E; Karaiskos P; Papagiannis P
Med Phys; 2013 Jan; 40(1):011712. PubMed ID: 23298082
[TBL] [Abstract][Full Text] [Related]
20. Point kernels and superposition methods for scatter dose calculations in brachytherapy.
Carlsson AK; Ahnesjö A
Phys Med Biol; 2000 Feb; 45(2):357-82. PubMed ID: 10701509
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]