These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

227 related articles for article (PubMed ID: 26109085)

  • 1. Improving stability of elastic stable intramedullary nailing in a transverse midshaft femur fracture model: biomechanical analysis of using end caps or a third nail.
    Rapp M; Gros N; Zachert G; Schulze-Hessing M; Stratmann C; Wendlandt R; Kaiser MM
    J Orthop Surg Res; 2015 Jun; 10():96. PubMed ID: 26109085
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Additional Tension Screws Improve Stability in Elastic Stable Intramedullary Nailing: Biomechanical Analysis of a Femur Spiral Fracture Model.
    Zachert G; Rapp M; Eggert R; Schulze-Hessing M; Gros N; Stratmann C; Wendlandt R; Kaiser MM
    Eur J Pediatr Surg; 2015 Aug; 25(4):365-72. PubMed ID: 24914565
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Modification of elastic stable intramedullary nailing with a 3rd nail in a femoral spiral fracture model - results of biomechanical testing and a prospective clinical study.
    Kaiser MM; Stratmann C; Zachert G; Schulze-Hessing M; Gros N; Eggert R; Rapp M
    BMC Musculoskelet Disord; 2014 Jan; 15():3. PubMed ID: 24397612
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Biomechanical analysis of a synthetic femoral spiral fracture model: Do end caps improve retrograde flexible intramedullary nail fixation?
    Kaiser MM; Zachert G; Wendlandt R; Rapp M; Eggert R; Stratmann C; Wessel LM; Schulz AP; Kienast BJ
    J Orthop Surg Res; 2011 Sep; 6():46. PubMed ID: 21923948
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Biomechanical Analysis of Retrograde Flexible Intramedullary Nail Constructs in a Simulated Pediatric Femur Fracture Model.
    Bland DC; Black SR; Pierce WA; Wimberly RL; Riccio AI
    J Pediatr Orthop; 2019 Jan; 39(1):22-27. PubMed ID: 28141692
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Computational comparison of tibial diaphyseal fractures fixed with various degrees of prebending of titanium elastic nails and with and without end caps.
    Chen YN; Lee PY; Chang CH; Chang CW; Ho YH; Li CT; Peng YT
    Injury; 2016 Oct; 47(10):2339-2346. PubMed ID: 27424533
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Biomechanical analysis of a synthetic femur spiral fracture model: Influence of different materials on the stiffness in flexible intramedullary nailing.
    Kaiser MM; Wessel LM; Zachert G; Stratmann C; Eggert R; Gros N; Schulze-Hessing M; Kienast B; Rapp M
    Clin Biomech (Bristol, Avon); 2011 Jul; 26(6):592-7. PubMed ID: 21345557
    [TBL] [Abstract][Full Text] [Related]  

  • 8. End caps prevent nail migration in elastic stable intramedullary nailing in paediatric femoral fractures: a biomechanical study using synthetic and cadaveric bones.
    Windolf M; Fischer MF; Popp AW; Matthys R; Schwieger K; Gueorguiev B; Hunter JB; Slongo TF
    Bone Joint J; 2015 Apr; 97-B(4):558-63. PubMed ID: 25820898
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Biomechanical analysis comparing titanium elastic nails with locked plating in two simulated pediatric femur fracture models.
    Porter SE; Booker GR; Parsell DE; Weber MD; Russell GV; Woodall J; Wagner M; Neubauer T
    J Pediatr Orthop; 2012 Sep; 32(6):587-93. PubMed ID: 22892620
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Increasing stability by pre-bending the nails in elastic stable intramedullary nailing: a biomechanical analysis of a synthetic femoral spiral fracture model.
    Kaiser MM; Zachert G; Wendlandt R; Eggert R; Stratmann C; Gros N; Schulze-Hessing M; Rapp M
    J Bone Joint Surg Br; 2012 May; 94(5):713-8. PubMed ID: 22529097
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Does the extent of prebending affect the stability of femoral shaft fractures stabilized by titanium elastic nails? A biomechanical investigation on an adolescent femur model.
    Doser A; Helwig P; Konstantinidis L; Kuminack KF; Südkamp NP; Strohm PC
    J Pediatr Orthop; 2011 Dec; 31(8):834-8. PubMed ID: 22101660
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A new intramedullary nailing device for the treatment of femoral shaft fractures: a biomechanical study.
    Wang G; Pan T; Peng X; Wang J
    Clin Biomech (Bristol, Avon); 2008 Mar; 23(3):305-12. PubMed ID: 18079030
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Setscrew distal locking for intramedullary nails: a biomechanical study.
    Köse N; Günal I; Wang X; Athanasiou KA; Agrawal CM; Mabrey JD
    J Orthop Trauma; 2000 Aug; 14(6):414-9. PubMed ID: 11001415
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Using flexible nails to improve stabilization of proximal femur fractures in adolescents.
    Crist BD; Dart BR; Czuwala PJ; Olney BW; Pence CD
    Am J Orthop (Belle Mead NJ); 2006 Jan; 35(1):37-41. PubMed ID: 16475423
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Biomechanical performance of flexible intramedullary nails with end caps tested in distal segmental defects of pediatric femur models.
    Volpon JB; Perina MM; Okubo R; Maranho DA
    J Pediatr Orthop; 2012; 32(5):461-6. PubMed ID: 22706460
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Ender nail fixation of pediatric femur fractures: a biomechanical analysis.
    Lee SS; Mahar AT; Newton PO
    J Pediatr Orthop; 2001; 21(4):442-5. PubMed ID: 11433153
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Biomechanical analysis of titanium elastic nail fixation in a pediatric femur fracture model.
    Li Y; Stabile KJ; Shilt JS
    J Pediatr Orthop; 2008 Dec; 28(8):874-8. PubMed ID: 19034181
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Influence of screw combination and nail materials in the stability of anterograde reamed intramedullary nail in distal femoral fractures.
    Gabarre S; Albareda J; Gracia L; Puértolas S; Ibarz E; Herrera A
    Injury; 2017 Nov; 48 Suppl 6():S47-S53. PubMed ID: 29162241
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Biomechanical analysis of antegrade and retrograde flexible intramedullary nail fixation of pediatric femoral fractures using a synthetic bone model.
    Fricka KB; Mahar AT; Lee SS; Newton PO
    J Pediatr Orthop; 2004; 24(2):167-71. PubMed ID: 15076601
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Biomechanical investigation of titanium elastic nail prebending for treating diaphyseal long bone fractures.
    Chen YN; Lee PY; Chang CW; Ho YH; Peng YT; Chang CH; Li CT
    Australas Phys Eng Sci Med; 2017 Mar; 40(1):115-126. PubMed ID: 27914012
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.