BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

225 related articles for article (PubMed ID: 26113034)

  • 1. What is the underlying mechanism for the failure mode observed in the proximal femoral locking compression plate? A biomechanical study.
    Schneider K; Oh JK; Zderic I; Stoffel K; Richards RG; Wolf S; Gueorguiev B; Nork SE
    Injury; 2015 Aug; 46(8):1483-90. PubMed ID: 26113034
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Biomechanical Analysis of the Proximal Femoral Locking Compression Plate: Do Quality of Reduction and Screw Orientation Influence Construct Stability?
    Zderic I; Oh JK; Stoffel K; Sommer C; Helfen T; Camino G; Richards G; Nork SE; Gueorguiev B
    J Orthop Trauma; 2018 Feb; 32(2):67-74. PubMed ID: 28834823
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Internal fixation of type-C distal femoral fractures in osteoporotic bone.
    Wähnert D; Hoffmeier KL; von Oldenburg G; Fröber R; Hofmann GO; Mückley T
    J Bone Joint Surg Am; 2010 Jun; 92(6):1442-52. PubMed ID: 20516320
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Rotationally Stable Screw-Anchor With Locked Trochanteric Stabilizing Plate Versus Proximal Femoral Nail Antirotation in the Treatment of AO/OTA 31A2.2 Fracture: A Biomechanical Evaluation.
    Knobe M; Nagel P; Maier KJ; Gradl G; Buecking B; Sönmez TT; Modabber A; Prescher A; Pape HC
    J Orthop Trauma; 2016 Jan; 30(1):e12-8. PubMed ID: 26849388
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Distal femoral fixation: a biomechanical comparison of trigen retrograde intramedullary (i.m.) nail, dynamic condylar screw (DCS), and locking compression plate (LCP) condylar plate.
    Heiney JP; Barnett MD; Vrabec GA; Schoenfeld AJ; Baji A; Njus GO
    J Trauma; 2009 Feb; 66(2):443-9. PubMed ID: 19204519
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Biomechanical comparison of two side plate fixation techniques in an unstable intertrochanteric osteotomy model: Sliding Hip Screw and Percutaneous Compression Plate.
    Krischak GD; Augat P; Beck A; Arand M; Baier B; Blakytny R; Gebhard F; Claes L
    Clin Biomech (Bristol, Avon); 2007 Dec; 22(10):1112-8. PubMed ID: 17900766
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Two-part surgical neck fractures of the proximal part of the humerus. A biomechanical evaluation of two fixation techniques.
    Edwards SL; Wilson NA; Zhang LQ; Flores S; Merk BR
    J Bone Joint Surg Am; 2006 Oct; 88(10):2258-64. PubMed ID: 17015605
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Semi-rigid screws provide an auxiliary option to plate working length to control interfragmentary movement in locking plate fixation at the distal femur.
    Heyland M; Duda GN; Haas NP; Trepczynski A; Döbele S; Höntzsch D; Schaser KD; Märdian S
    Injury; 2015 Oct; 46 Suppl 4():S24-32. PubMed ID: 26542863
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Internal fixation of type-C distal femoral fractures in osteoporotic bone: surgical technique.
    Mückley T; Wähnert D; Hoffmeier KL; von Oldenburg G; Fröber R; Hofmann GO
    J Bone Joint Surg Am; 2011 Mar; 93 Suppl 1():40-53. PubMed ID: 21411685
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Filling Open Screw Holes in the Area of Metaphyseal Comminution Does Not Affect Fatigue Life of the Synthes Variable Angle Distal Femoral Locking Plate in the AO/OTA 33-A3 Fracture Model.
    Grau L; Collon K; Alhandi A; Kaimrajh D; Varon M; Latta L; Vilella F
    Surg Technol Int; 2018 Jun; 32():293-297. PubMed ID: 29791694
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Biomechanical comparative study on proximal femoral locking plate and Gamma3 for treatment of stable intertrochanteric fracture].
    Jiang W; Liu Y; Yang L; Xu W; Liu S; Zhang D; Chen X; Wang H
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2014 Sep; 28(9):1096-9. PubMed ID: 25509773
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Biomechanical comparison of polyaxial-type locking plates and a fixed-angle locking plate for internal fixation of distal femur fractures.
    Otto RJ; Moed BR; Bledsoe JG
    J Orthop Trauma; 2009 Oct; 23(9):645-52. PubMed ID: 19897986
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A biomechanical comparison of locked plate fixation with percutaneous insertion capability versus the angled blade plate in a subtrochanteric fracture gap model.
    Crist BD; Khalafi A; Hazelwood SJ; Lee MA
    J Orthop Trauma; 2009 Oct; 23(9):622-7. PubMed ID: 19897982
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A biomechanical study comparing proximal femur nail and proximal femur locking compression plate in fixation of reverse oblique proximal femur fractures.
    Singh AK; Narsaria N; Gupta RK
    Injury; 2017 Oct; 48(10):2050-2053. PubMed ID: 28801202
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Locking plates increase the strength of dynamic hip screws.
    Jewell DP; Gheduzzi S; Mitchell MS; Miles AW
    Injury; 2008 Feb; 39(2):209-12. PubMed ID: 17880976
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Vertically oriented femoral neck fractures: mechanical analysis of four fixation techniques.
    Aminian A; Gao F; Fedoriw WW; Zhang LQ; Kalainov DM; Merk BR
    J Orthop Trauma; 2007 Sep; 21(8):544-8. PubMed ID: 17805021
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Polyaxial locking plate fixation in distal femur fractures: a biomechanical comparison.
    Wilkens KJ; Curtiss S; Lee MA
    J Orthop Trauma; 2008 Oct; 22(9):624-8. PubMed ID: 18827592
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Implant Material, Type of Fixation at the Shaft, and Position of Plate Modify Biomechanics of Distal Femur Plate Osteosynthesis.
    Kandemir U; Augat P; Konowalczyk S; Wipf F; von Oldenburg G; Schmidt U
    J Orthop Trauma; 2017 Aug; 31(8):e241-e246. PubMed ID: 28394844
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Tangential Bicortical Locked Fixation Improves Stability in Vancouver B1 Periprosthetic Femur Fractures: A Biomechanical Study.
    Lewis GS; Caroom CT; Wee H; Jurgensmeier D; Rothermel SD; Bramer MA; Reid JS
    J Orthop Trauma; 2015 Oct; 29(10):e364-70. PubMed ID: 26053467
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Biomechanical evaluation of fracture fixation constructs using a variable-angle locked periprosthetic femur plate system.
    Hoffmann MF; Burgers TA; Mason JJ; Williams BO; Sietsema DL; Jones CB
    Injury; 2014 Jul; 45(7):1035-41. PubMed ID: 24680467
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.