These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

104 related articles for article (PubMed ID: 26113736)

  • 1. Analytical imprecision of lactate dehydrogenase in primary serum tubes.
    Buonocore R; Avanzini P; Aloe R; Lippi G
    Ann Clin Biochem; 2016 May; 53(Pt 3):405-8. PubMed ID: 26113736
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Non-homogeneous separation of triglycerides, gamma-glutamyltransferase, C-reactive protein and lactate dehydrogenase after centrifugation of lithium-heparin tubes.
    Salvagno GL; Lippi G; Montagnana M; Brocco G; Guidi GC
    Clin Chem Lab Med; 2008; 46(8):1180-2. PubMed ID: 18724811
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Cellular content in plasma of Becton-Dickinson lithium-heparin tubes: cause of unreliable results in the IFCC-recommended lactate dehydrogenase method.
    Bakker AJ; Bakker A; Renting-Wiering H
    Ann Clin Biochem; 2006 Nov; 43(Pt 6):510-2. PubMed ID: 17132285
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The quality of diagnostic testing may be impaired during shipment of lithium-heparin gel tubes.
    Da Rin G; Lippi G
    Clin Chem Lab Med; 2014 Nov; 52(11):1633-7. PubMed ID: 24960155
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Check-in and sorting of centrifuged serum and lithium-heparin tubes may be unsuitable using a bulk input module.
    Da Rin G; Lippi G
    J Lab Autom; 2014 Oct; 19(5):474-7. PubMed ID: 24865175
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Falsely Increased Plasma Lactate Dehydrogenase without Hemolysis Following Transport through Pneumatic Tube System.
    Herman DS; Toro E; Baraban EG; Bagg A; Wang P
    J Appl Lab Med; 2019 Nov; 4(3):433-438. PubMed ID: 31659082
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A new assay falsely increases lactate dehydrogenase in plasma but not in serum.
    Rasmussen MS; Pedersen L
    Clin Biochem; 2024 Oct; 131-132():110804. PubMed ID: 39079578
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Analytical Performance Verification of the Beckman Coulter AU5800 Clinical Chemistry Analyser Against Recognized Quality Specifications Reveals Relevance of Method Harmonization.
    Glibert B; Bourleaux V; Peeters R; Reynolds T; Vranken G
    Clin Lab; 2016; 62(1-2):57-72. PubMed ID: 27012034
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Development of an enzymatic assay to measure lactate in perchloric acid-precipitated cerebrospinal fluid.
    Lu J; Genzen JR; Grenache DG
    Clin Chim Acta; 2018 Aug; 483():142-144. PubMed ID: 29709451
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The impact of different sample matrices in delayed measurement of glucose.
    Roccaforte V; Daves M; Platzgummer S; Lippi G
    Clin Biochem; 2016 Dec; 49(18):1412-1415. PubMed ID: 27567939
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Glucose is stable during prolonged storage in un-centrifuged Greiner tubes with liquid citrate buffer, but not in serum and NaF/KOx tubes.
    Juricic G; Bakliza A; Saracevic A; Kopcinovic LM; Dobrijevic S; Drmic S; Simundic AM
    Clin Chem Lab Med; 2016 Mar; 54(3):411-8. PubMed ID: 26695197
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Impact of blood cell counts and volumes on glucose concentration in uncentrifuged serum and lithium-heparin blood tubes.
    Lippi G; Salvagno GL; Lampus S; Danese E; Gelati M; Bovo C; Montagnana M; Simundic AM
    Clin Chem Lab Med; 2018 Nov; 56(12):2125-2131. PubMed ID: 29935113
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Gentle blood aspiration and tube cushioning reduce pneumatic tube system interference in lactate dehydrogenase assays.
    Strubi-Vuillaume I; Carlier V; Obeuf C; Vasseur F; Maury JC; Maboudou P; Mangalaboyi J; Durocher A; Launay D; Noel C; Brousseau T
    Ann Clin Biochem; 2016 Mar; 53(Pt 2):295-7. PubMed ID: 25911571
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Relationship between sampling volume of primary serum tubes and spurious hemolysis.
    Lippi G; Musa R; Battistelli L; Cervellin G
    Clin Lab; 2012; 58(11-12):1187-91. PubMed ID: 23289188
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Studies on the use of BD Vacutainer® SST II™ and RST™ in general practice: investigation of artefactual hyperkalaemia.
    Huyghe T; Buntinx F; Bruyninckx R; Besard V; Vunckx J; Church S; Byron K; Rosa R; Blanckaert N
    Ann Clin Biochem; 2014 Jan; 51(Pt 1):30-7. PubMed ID: 23897107
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Routine sample transportation of centrifuged barrier tubes impacts certain chemistry analytes.
    Wang J; Pyle-Eilola AL
    Clin Biochem; 2023 May; 115():77-80. PubMed ID: 36058286
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Commutable calibrator with value assigned by the IFCC reference procedure to harmonize serum lactate dehydrogenase activity results measured by 2 different methods.
    Cattozzo G; Guerra E; Ceriotti F; Franzini C;
    Clin Chem; 2008 Aug; 54(8):1349-55. PubMed ID: 18539646
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Specimen processing time and measurement of total insulin-like growth factor-I (IGF-I), free IGF-I, and IGF binding protein-3 (IGFBP-3).
    Harris TG; Strickler HD; Yu H; Pollak MN; Monrad ES; Travin MI; Xue X; Rohan TE; Kaplan RC
    Growth Horm IGF Res; 2006 Apr; 16(2):86-92. PubMed ID: 16530441
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effectiveness of citrate buffer-fluoride mixture in Terumo tubes as an inhibitor of in vitro glycolysis.
    Bonetti G; Carta M; Montagnana M; Lo Cascio C; Bonfigli AR; Mosca A; Testa R;
    Biochem Med (Zagreb); 2016; 26(1):68-76. PubMed ID: 26981020
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Incomplete filling of lithium heparin tubes affects the activity of creatine kinase and gamma-glutamyltransferase.
    Lippi G; Avanzini P; Cosmai M; Aloe R; Ernst D
    Br J Biomed Sci; 2012; 69(2):67-70. PubMed ID: 22872930
    [TBL] [Abstract][Full Text] [Related]  