These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
149 related articles for article (PubMed ID: 26116326)
1. [Influence of body position on the displacement of nasal prongs in preterm newborns receiving continuous positive airway pressure]. Brunherotti MA; Martinez FE Rev Paul Pediatr; 2015; 33(3):281-6. PubMed ID: 26116326 [TBL] [Abstract][Full Text] [Related]
2. Effect of body position on preterm newborns receiving continuous positive airway pressure. Brunherotti MA; Martinez EZ; Martinez FE Acta Paediatr; 2014 Mar; 103(3):e101-5. PubMed ID: 24354904 [TBL] [Abstract][Full Text] [Related]
3. Effect of Body Position on Cardiorespiratory Stabilization and Comfort in Preterm Infants on Continuous Positive Airway Pressure. Çakıcı M; Mutlu B J Pediatr Nurs; 2020; 54():e1-e8. PubMed ID: 32680615 [TBL] [Abstract][Full Text] [Related]
4. [Cardiorespiratory effects of the body position in premature newborns submitted to the increase of the gastric volume]. Pádua Gd; Martinez EZ; Brunherotti MA Arq Gastroenterol; 2009; 46(4):321-7. PubMed ID: 20232014 [TBL] [Abstract][Full Text] [Related]
5. Effect of body position on ventilation distribution in preterm infants on continuous positive airway pressure. Hough JL; Johnston L; Brauer SG; Woodgate PG; Pham TM; Schibler A Pediatr Crit Care Med; 2012 Jul; 13(4):446-51. PubMed ID: 21926660 [TBL] [Abstract][Full Text] [Related]
6. Nasal Mask Versus Nasal Prongs for Delivering Nasal Continuous Positive Airway Pressure in Preterm Infants with Respiratory Distress: A Randomized Controlled Trial. Goel S; Mondkar J; Panchal H; Hegde D; Utture A; Manerkar S Indian Pediatr; 2015 Dec; 52(12):1035-40. PubMed ID: 26713987 [TBL] [Abstract][Full Text] [Related]
7. Randomized trial of prongs or mask for nasal continuous positive airway pressure in preterm infants. Kieran EA; Twomey AR; Molloy EJ; Murphy JF; O'Donnell CP Pediatrics; 2012 Nov; 130(5):e1170-6. PubMed ID: 23090339 [TBL] [Abstract][Full Text] [Related]
9. Helmet Versus Nasal-Prong CPAP in Infants With Acute Bronchiolitis. Mayordomo-Colunga J; Rey C; Medina A; Martínez-Camblor P; Vivanco-Allende A; Concha A Respir Care; 2018 Apr; 63(4):455-463. PubMed ID: 29382794 [TBL] [Abstract][Full Text] [Related]
10. Nasal masks or binasal prongs for delivering continuous positive airway pressure in preterm neonates-a randomised trial. Chandrasekaran A; Thukral A; Jeeva Sankar M; Agarwal R; Paul VK; Deorari AK Eur J Pediatr; 2017 Mar; 176(3):379-386. PubMed ID: 28091776 [TBL] [Abstract][Full Text] [Related]
11. Positioning effects on lung function and breathing pattern in premature newborns. Gouna G; Rakza T; Kuissi E; Pennaforte T; Mur S; Storme L J Pediatr; 2013 Jun; 162(6):1133-7, 1137.e1. PubMed ID: 23312684 [TBL] [Abstract][Full Text] [Related]
12. Semi-Prone Position Can Influence Variability in Respiratory Rate of Premature Infants Using Nasal CPAP. Yin T; Yuh YS; Liaw JJ; Chen YY; Wang KW J Pediatr Nurs; 2016; 31(2):e167-74. PubMed ID: 26614613 [TBL] [Abstract][Full Text] [Related]
13. Effects of flow amplitudes on intraprong pressures during bubble versus ventilator-generated nasal continuous positive airway pressure in premature infants. Kahn DJ; Habib RH; Courtney SE Pediatrics; 2008 Nov; 122(5):1009-13. PubMed ID: 18977980 [TBL] [Abstract][Full Text] [Related]
14. Does the RAM Cannula Provide Continuous Positive Airway Pressure as Effectively as the Hudson Prongs in Preterm Neonates? Singh N; McNally MJ; Darnall RA Am J Perinatol; 2019 Jul; 36(8):849-854. PubMed ID: 30396227 [TBL] [Abstract][Full Text] [Related]
15. Comparison of two nasal prongs for application of continuous positive airway pressure in neonates. Rego MA; Martinez FE Pediatr Crit Care Med; 2002 Jul; 3(3):239-243. PubMed ID: 12780963 [TBL] [Abstract][Full Text] [Related]
16. Mask versus nasal prong leak and intermittent hypoxia during continuous positive airway pressure in very preterm infants. Poets CF; Lim K; Marshall A; Jackson H; Gale TJ; Dargaville PA Arch Dis Child Fetal Neonatal Ed; 2021 Jan; 106(1):81-83. PubMed ID: 32796057 [TBL] [Abstract][Full Text] [Related]
17. A multicenter randomized controlled trial comparing effectiveness of two nasal continuous positive airway pressure devices in very-low-birth-weight infants. Bober K; Świetliński J; Zejda J; Kornacka K; Pawlik D; Behrendt J; Gajewska E; Czyżewska M; Korbal P; Witalis J; Walas W; Wilińska M; Turzańska A; Zieliński G; Czeszyńska B; Bachman T Pediatr Crit Care Med; 2012 Mar; 13(2):191-6. PubMed ID: 21666531 [TBL] [Abstract][Full Text] [Related]
18. Comparing the effect of two different interfaces on breathing of preterm infants at birth: A matched-pairs analysis. Kuypers KLAM; Lamberska T; Martherus T; Dekker J; Böhringer S; Hooper SB; Plavka R; Te Pas AB Resuscitation; 2020 Dec; 157():60-66. PubMed ID: 33075437 [TBL] [Abstract][Full Text] [Related]