122 related articles for article (PubMed ID: 26121944)
1. Reply to "Misconceptions in the assessment of cough peak flow measurements for extubation or decanulation protocols".
Winck JC; LeBlanc C; Soto JL; Plano F
Rev Port Pneumol (2006); 2015; 21(5):286-7. PubMed ID: 26121944
[No Abstract] [Full Text] [Related]
2. Misconceptions in the assessment of cough peak flow measurements for extubation or decanulation protocols.
Chiou M; Bach JR; Gonçalves MR; Vudayagiri L
Rev Port Pneumol (2006); 2015; 21(5):285-6. PubMed ID: 26111931
[No Abstract] [Full Text] [Related]
3. The value of cough peak flow measurements in the assessment of extubation or decannulation readiness.
Winck JC; LeBlanc C; Soto JL; Plano F
Rev Port Pneumol (2006); 2015; 21(2):94-8. PubMed ID: 25926373
[TBL] [Abstract][Full Text] [Related]
4. Voluntary is better than involuntary cough peak flow for predicting re-intubation after scheduled extubation in cooperative subjects.
Duan J; Liu J; Xiao M; Yang X; Wu J; Zhou L
Respir Care; 2014 Nov; 59(11):1643-51. PubMed ID: 25140034
[TBL] [Abstract][Full Text] [Related]
5. The Strong Cough: Is It a Signpost on the Road to Extubation or Just a Dead End?
Nguyen AP; Schmidt UH
Respir Care; 2017 Dec; 62(12):1611-1612. PubMed ID: 29162729
[No Abstract] [Full Text] [Related]
6. Use of Cough Peak Flow Measured by a Ventilator to Predict Re-Intubation When a Spirometer Is Unavailable.
Bai L; Duan J
Respir Care; 2017 May; 62(5):566-571. PubMed ID: 28246308
[TBL] [Abstract][Full Text] [Related]
7. Attenuation of cardiovascular and cough reflexes during extubation.
Palfreman TM; Wakeling HG
Anaesthesia; 2002 Oct; 57(10):1034-5; author reply 1035. PubMed ID: 12358971
[No Abstract] [Full Text] [Related]
8. Semiquantitative cough strength score for predicting reintubation after planned extubation.
Duan J; Zhou L; Xiao M; Liu J; Yang X
Am J Crit Care; 2015 Nov; 24(6):e86-90. PubMed ID: 26523016
[TBL] [Abstract][Full Text] [Related]
9. [The application of fibrobronchoscopy in extubation for patients suffering from acute exacerbation of chronic obstructive pulmonary disease with low cough peak expiratory flow].
Liu X; Li Y; He W; Xu Y; Sang L
Zhonghua Wei Zhong Bing Ji Jiu Yi Xue; 2014 Dec; 26(12):855-9. PubMed ID: 25476075
[TBL] [Abstract][Full Text] [Related]
10. Weaning attempts, cough strength and albumin are independent risk factors of reintubation in medical patients.
Xiao M; Duan J
Clin Respir J; 2018 Mar; 12(3):1240-1246. PubMed ID: 28586526
[TBL] [Abstract][Full Text] [Related]
11. The effects of lidocaine spray and intracuff alkalinized lidocaine on the occurrence of cough at extubation: a double-blind randomized controlled trial.
D'Aragon F; Beaudet N; Gagnon V; Martin R; Sansoucy Y
Can J Anaesth; 2013 Apr; 60(4):370-6. PubMed ID: 23370978
[TBL] [Abstract][Full Text] [Related]
12. Predicting Extubation Outcome by Cough Peak Flow Measured Using a Built-in Ventilator Flow Meter.
Gobert F; Yonis H; Tapponnier R; Fernandez R; Labaune MA; Burle JF; Barbier J; Vincent B; Cleyet M; Richard JC; Guérin C
Respir Care; 2017 Dec; 62(12):1505-1519. PubMed ID: 28900041
[TBL] [Abstract][Full Text] [Related]
13. Is there a role for cough suppression techniques in the COVID-19 era?
Cribben N; Nita C; O'Doherty R
Anaesthesia; 2021 Mar; 76 Suppl 3():13-14. PubMed ID: 33169833
[No Abstract] [Full Text] [Related]
14. [A study of cough peak expiratory flow in predicting extubation outcome].
Gao XJ; Qin YZ
Zhongguo Wei Zhong Bing Ji Jiu Yi Xue; 2009 Jul; 21(7):390-3. PubMed ID: 19615127
[TBL] [Abstract][Full Text] [Related]
15. Tolerability of the Cook staged extubation wire. A reply.
McManus S; Anstey C; Jones L; Senthuran S
Anaesthesia; 2018 Sep; 73(9):1170. PubMed ID: 30132813
[No Abstract] [Full Text] [Related]
16. [Comparison between flexible laryngeal mask airway and reinforced tracheal tube used for lumbar vertebral surgery in prone position].
Zheng YL; Song WF; Wang DX
Beijing Da Xue Xue Bao Yi Xue Ban; 2017 Apr; 49(2):262-266. PubMed ID: 28416836
[TBL] [Abstract][Full Text] [Related]
17. Comparison of cough reflex testing with videoendoscopy in recently extubated intensive care unit patients.
Kallesen M; Psirides A; Huckabee ML
J Crit Care; 2016 Jun; 33():90-4. PubMed ID: 26993369
[TBL] [Abstract][Full Text] [Related]
18. The use of a supraglottic airway device as an extubation bridge for the difficult airway.
El-Orbany M
Can J Anaesth; 2014 Apr; 61(4):387-8. PubMed ID: 24493582
[No Abstract] [Full Text] [Related]
19. Reply to letter: Response to the letter «Anaesthesia management of accidental extubation in the prone position».
Bosch L; Sadurní M; Pacreu S
Rev Esp Anestesiol Reanim; 2017 Dec; 64(10):601. PubMed ID: 28693901
[No Abstract] [Full Text] [Related]
20. Clinical Criteria for Tracheostomy Decannulation in Subjects with Acquired Brain Injury.
Enrichi C; Battel I; Zanetti C; Koch I; Ventura L; Palmer K; Meneghello F; Piccione F; Rossi S; Lazzeri M; Sommariva M; Turolla A
Respir Care; 2017 Oct; 62(10):1255-1263. PubMed ID: 28698267
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]