These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

334 related articles for article (PubMed ID: 2612679)

  • 21. Comparison of the ICare rebound tonometer with the Goldmann tonometer in a normal population.
    Fernandes P; Díaz-Rey JA; Queirós A; Gonzalez-Meijome JM; Jorge J
    Ophthalmic Physiol Opt; 2005 Sep; 25(5):436-40. PubMed ID: 16101950
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Comparison of the Tono-Pen and Goldmann tonometer for measuring intraocular pressure in patients with glaucoma.
    Horowitz GS; Byles J; Lee J; D'Este C
    Clin Exp Ophthalmol; 2004 Dec; 32(6):584-9. PubMed ID: 15575828
    [TBL] [Abstract][Full Text] [Related]  

  • 23. [The American Optical non-contact tonometer and its results compared with the Goldmann applanation tonometer (author's transl)].
    Derka H
    Klin Monbl Augenheilkd; 1980 Nov; 177(5):634-42. PubMed ID: 7253520
    [TBL] [Abstract][Full Text] [Related]  

  • 24. The pressure phosphene tonometer--a clinical evaluation.
    Chew GS; Sanderson GF; Molteno AC
    Eye (Lond); 2005 Jun; 19(6):683-5. PubMed ID: 15192693
    [TBL] [Abstract][Full Text] [Related]  

  • 25. [Comparative pressure measurements with the non-contact tonometer and the Goldmann applanation tonometer].
    Langmann G; Schuhmann G; Schwaiger W
    Klin Monbl Augenheilkd; 1985 Nov; 187(5):345-7. PubMed ID: 4087781
    [TBL] [Abstract][Full Text] [Related]  

  • 26. [Tonometry with a new non-contact tonometer].
    Langmann G; Schuhmann G; Langmann A; Zenz H
    Klin Monbl Augenheilkd; 1990 Nov; 197(5):393-6. PubMed ID: 2290296
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Measurement of the intraocular pressure with the "transpalpebral tonometer" TGDc-01 in comparison with applanation tonometry.
    Sandner D; Böhm A; Kostov S; Pillunat L
    Graefes Arch Clin Exp Ophthalmol; 2005 Jun; 243(6):563-9. PubMed ID: 15614540
    [TBL] [Abstract][Full Text] [Related]  

  • 28. [Evaluation of accuracy of measuring intraocular pressure by handheld non-contact applanation tonometer].
    Chen X; Peng D; Zhou W; Zhong Y
    Yan Ke Xue Bao; 1995 Jun; 11(2):86-8. PubMed ID: 9208659
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Comparison of intraocular pressure measured by non-contact air puff versus Goldmann applanation tonometers in gas-filled vitrectomized eyes.
    Patikulsila D; Taweemankongsab S; Ngamtipakorn S
    J Med Assoc Thai; 2003 May; 86(5):467-72. PubMed ID: 12859105
    [TBL] [Abstract][Full Text] [Related]  

  • 30. [Clinical comparison of the Tono-Pen tonometer to the Goldmann applanation tonometer].
    Jiang B; Jiang Y
    Yan Ke Xue Bao; 2002 Dec; 18(4):226-9. PubMed ID: 15515766
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Comparison of the ICare rebound tonometer with the Goldmann applanation tonometer by experienced and inexperienced tonometrists.
    Abraham LM; Epasinghe NC; Selva D; Casson R
    Eye (Lond); 2008 Apr; 22(4):503-6. PubMed ID: 17159973
    [TBL] [Abstract][Full Text] [Related]  

  • 32. New Tonopen XL: comparison with the Goldmann tonometer.
    Iester M; Mermoud A; Achache F; Roy S
    Eye (Lond); 2001 Feb; 15(Pt 1):52-8. PubMed ID: 11318296
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Comparison of goldmann applanation tonometer, noncontact tonometer, and TonoPen XL for intraocular pressure measurement in different types of glaucomatous, ocular hypertensive, and normal eyes.
    Kim NR; Kim CY; Kim H; Seong GJ; Lee ES
    Curr Eye Res; 2011 Apr; 36(4):295-300. PubMed ID: 21284505
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Microprocessor controlled tonometry.
    Draeger J; Rumberger E; Dauper J; Deutsch C
    Eye (Lond); 1989; 3 ( Pt 6)():738-42. PubMed ID: 2630355
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Three portable tonometers, the TGDc-01, the ICARE and the Tonopen XL, compared with each other and with Goldmann applanation tonometry*.
    van der Jagt LH; Jansonius NM
    Ophthalmic Physiol Opt; 2005 Sep; 25(5):429-35. PubMed ID: 16101949
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Comparison of dynamic contour tonometry with Goldmann applanation tonometry in glaucoma practice.
    Halkiadakis I; Patsea E; Chatzimichali K; Skouriotis S; Chalkidou S; Amariotakis G; Papakonstadinou D; Theodossiadis G; Amariotakis A; Georgopoulos G
    Acta Ophthalmol; 2009 May; 87(3):323-8. PubMed ID: 18631335
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Intraocular pressure measurement in children using the Keeler Pulsair tonometer.
    Evans K; Wishart PK
    Ophthalmic Physiol Opt; 1992 Jul; 12(3):287-90. PubMed ID: 1454364
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Comparison of the Pulsair noncontact tonometer and the Goldmann applanation tonometer.
    Climenhaga H; Plucinska H
    Can J Ophthalmol; 1989 Feb; 24(1):7-9. PubMed ID: 2713754
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Evaluation of the Tono-Pen and the Pulsair tonometers.
    Armstrong TA
    Am J Ophthalmol; 1990 Jun; 109(6):716-20. PubMed ID: 2346202
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Comparison of the IOPen and iCare rebound tonometers with the Goldmann tonometer in a normal population.
    Jorge J; Fernandes P; Queirós A; Ribeiro P; Garcês C; Gonzalez-Meijome JM
    Ophthalmic Physiol Opt; 2010 Jan; 30(1):108-12. PubMed ID: 20444114
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 17.