These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

148 related articles for article (PubMed ID: 26126964)

  • 21. A structural mechanism for MscS gating in lipid bilayers.
    Vásquez V; Sotomayor M; Cordero-Morales J; Schulten K; Perozo E
    Science; 2008 Aug; 321(5893):1210-4. PubMed ID: 18755978
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Open channel structure of MscL and the gating mechanism of mechanosensitive channels.
    Perozo E; Cortes DM; Sompornpisut P; Kloda A; Martinac B
    Nature; 2002 Aug; 418(6901):942-8. PubMed ID: 12198539
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Cysteine scanning of MscL transmembrane domains reveals residues critical for mechanosensitive channel gating.
    Levin G; Blount P
    Biophys J; 2004 May; 86(5):2862-70. PubMed ID: 15111403
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Bacterial mechanosensitive channels--MscS: evolution's solution to creating sensitivity in function.
    Naismith JH; Booth IR
    Annu Rev Biophys; 2012; 41():157-77. PubMed ID: 22404681
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Structure of a potentially open state of a proton-activated pentameric ligand-gated ion channel.
    Hilf RJ; Dutzler R
    Nature; 2009 Jan; 457(7225):115-8. PubMed ID: 18987630
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Lipid-protein interaction of the MscS mechanosensitive channel examined by scanning mutagenesis.
    Nomura T; Sokabe M; Yoshimura K
    Biophys J; 2006 Oct; 91(8):2874-81. PubMed ID: 16861270
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Rapid and improved reconstitution of bacterial mechanosensitive ion channel proteins MscS and MscL into liposomes using a modified sucrose method.
    Battle AR; Petrov E; Pal P; Martinac B
    FEBS Lett; 2009 Jan; 583(2):407-12. PubMed ID: 19111548
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Conformational state of the MscS mechanosensitive channel in solution revealed by pulsed electron-electron double resonance (PELDOR) spectroscopy.
    Pliotas C; Ward R; Branigan E; Rasmussen A; Hagelueken G; Huang H; Black SS; Booth IR; Schiemann O; Naismith JH
    Proc Natl Acad Sci U S A; 2012 Oct; 109(40):E2675-82. PubMed ID: 23012406
    [TBL] [Abstract][Full Text] [Related]  

  • 29. The impact of the C-terminal domain on the gating properties of MscCG from Corynebacterium glutamicum.
    Nakayama Y; Becker M; Ebrahimian H; Konishi T; Kawasaki H; Krämer R; Martinac B
    Biochim Biophys Acta; 2016 Jan; 1858(1):130-8. PubMed ID: 26494188
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Purification of the small mechanosensitive channel of Escherichia coli (MscS): the subunit structure, conduction, and gating characteristics in liposomes.
    Sukharev S
    Biophys J; 2002 Jul; 83(1):290-8. PubMed ID: 12080120
    [TBL] [Abstract][Full Text] [Related]  

  • 31. The closed structure of the MscS mechanosensitive channel. Cross-linking of single cysteine mutants.
    Miller S; Edwards MD; Ozdemir C; Booth IR
    J Biol Chem; 2003 Aug; 278(34):32246-50. PubMed ID: 12767977
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Conformational changes involved in MscL channel gating measured using FRET spectroscopy.
    Corry B; Rigby P; Liu ZW; Martinac B
    Biophys J; 2005 Dec; 89(6):L49-51. PubMed ID: 16199508
    [TBL] [Abstract][Full Text] [Related]  

  • 33. An optimized purification and reconstitution method for the MscS channel: strategies for spectroscopical analysis.
    Vásquez V; Cortes DM; Furukawa H; Perozo E
    Biochemistry; 2007 Jun; 46(23):6766-73. PubMed ID: 17500538
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Three-dimensional architecture of membrane-embedded MscS in the closed conformation.
    Vásquez V; Sotomayor M; Cortes DM; Roux B; Schulten K; Perozo E
    J Mol Biol; 2008 Apr; 378(1):55-70. PubMed ID: 18343404
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Mechanosensitive channel of Thermoplasma, the cell wall-less archaea: cloning and molecular characterization.
    Kloda A; Martinac B
    Cell Biochem Biophys; 2001; 34(3):321-47. PubMed ID: 11898860
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Identification of a chameleon-like pH-sensitive segment within the colicin E1 channel domain that may serve as the pH-activated trigger for membrane bilayer association.
    Merrill AR; Steer BA; Prentice GA; Weller MJ; Szabo AG
    Biochemistry; 1997 Jun; 36(23):6874-84. PubMed ID: 9188682
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Hydration properties of mechanosensitive channel pores define the energetics of gating.
    Anishkin A; Akitake B; Kamaraju K; Chiang CS; Sukharev S
    J Phys Condens Matter; 2010 Nov; 22(45):454120. PubMed ID: 21339607
    [TBL] [Abstract][Full Text] [Related]  

  • 38. The conserved carboxy-terminus of the MscS mechanosensitive channel is not essential but increases stability and activity.
    Schumann U; Edwards MD; Li C; Booth IR
    FEBS Lett; 2004 Aug; 572(1-3):233-7. PubMed ID: 15304354
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Electrostatic couplings in OmpA ion-channel gating suggest a mechanism for pore opening.
    Hong H; Szabo G; Tamm LK
    Nat Chem Biol; 2006 Nov; 2(11):627-35. PubMed ID: 17041590
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Electromechanical coupling model of gating the large mechanosensitive ion channel (MscL) of Escherichia coli by mechanical force.
    Gu L; Liu W; Martinac B
    Biophys J; 1998 Jun; 74(6):2889-902. PubMed ID: 9635742
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.