BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

2079 related articles for article (PubMed ID: 26126991)

  • 1. Do alumina matrix composite bearings decrease hip noises and bearing fractures at a minimum of 5 years after THA?
    Baek SH; Kim WK; Kim JY; Kim SY
    Clin Orthop Relat Res; 2015 Dec; 473(12):3796-802. PubMed ID: 26126991
    [TBL] [Abstract][Full Text] [Related]  

  • 2. What Is the Frequency of Fracture of Ceramic Components in THA? Results from the Norwegian Arthroplasty Register from 1997 to 2017.
    Hallan G; Fenstad AM; Furnes O
    Clin Orthop Relat Res; 2020 Jun; 478(6):1254-1261. PubMed ID: 32348085
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Primary ceramic-on-ceramic total hip arthroplasty using a 32-mm ceramic head with a titanium-alloy sleeve.
    Lim SJ; Jang SP; Kim DW; Moon YW; Park YS
    Clin Orthop Relat Res; 2015 Dec; 473(12):3781-7. PubMed ID: 26024582
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Ceramic-on-ceramic THA Implants in Patients Younger Than 20 Years.
    Hannouche D; Devriese F; Delambre J; Zadegan F; Tourabaly I; Sedel L; Chevret S; Nizard R
    Clin Orthop Relat Res; 2016 Feb; 474(2):520-7. PubMed ID: 26341897
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Ceramic-on-ceramic THA associated with fewer dislocations and less muscle degeneration by preserving muscle progenitors.
    Hernigou P; Roussignol X; Delambre J; Poignard A; Flouzat-Lachaniette CH
    Clin Orthop Relat Res; 2015 Dec; 473(12):3762-9. PubMed ID: 26054482
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Do the Reasons for Ceramic-on-ceramic Revisions Differ From Other Bearings in Total Hip Arthroplasty?
    Migaud H; Putman S; Kern G; Isida R; Girard J; Ramdane N; Delaunay CP; Hamadouche M;
    Clin Orthop Relat Res; 2016 Oct; 474(10):2190-9. PubMed ID: 27255729
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Hard-on-Hard Bearings Are Associated With Increased Noise Generation in Young Patients Undergoing Hip Arthroplasty.
    Nam D; Barrack T; Johnson SR; Nunley RM; Barrack RL
    Clin Orthop Relat Res; 2016 Oct; 474(10):2115-22. PubMed ID: 26911973
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Are ceramic-on-ceramic bearings in total hip arthroplasty associated with reduced revision risk for late dislocation?
    Pitto RP; Garland M; Sedel L
    Clin Orthop Relat Res; 2015 Dec; 473(12):3790-5. PubMed ID: 26070775
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Squeaking Is Common and Increases Over Time Among Patients With Long-term Follow-up After Ceramic-on-ceramic THA.
    Taniguchi K; Quacinella M; Barlow B
    Clin Orthop Relat Res; 2021 Apr; 479(4):736-744. PubMed ID: 33724977
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Ten-year results after cementless THA with a sandwich-type alumina ceramic bearing.
    Park YS; Park SJ; Lim SJ
    Orthopedics; 2010 Nov; 33(11):796. PubMed ID: 21053885
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Clinical Outcomes and Bearing-Specific Complications Following Fourth-Generation Alumina Ceramic-on-Ceramic Total Hip Arthroplasty: A Single-Surgeon Series of 749 Hips at a Minimum of 5-Year Follow-Up.
    Lim SJ; Ryu HG; Eun HJ; Park CW; Kwon KB; Park YS
    J Arthroplasty; 2018 Jul; 33(7):2182-2186.e1. PubMed ID: 29599034
    [TBL] [Abstract][Full Text] [Related]  

  • 12. High Risk of Neck-liner Impingement and Notching Observed with Thick Femoral Neck Implants in Ceramic-on-ceramic THA.
    Kim HS; Park JW; Lee SJ; Lee YK; Ha YC; Koo KH
    Clin Orthop Relat Res; 2022 Apr; 480(4):690-699. PubMed ID: 34699410
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Periprosthetic Joint Infection in Hip Arthroplasty: Is There an Association Between Infection and Bearing Surface Type?
    Pitto RP; Sedel L
    Clin Orthop Relat Res; 2016 Oct; 474(10):2213-8. PubMed ID: 27249955
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Pure alumina bearings with cementless stems versus sandwich bearings with cemented stems in total hip arthroplasty.
    Wu HB; Cai YZ; Xin ZF; Wang XH; Yan SG
    Chin Med J (Engl); 2012 Jan; 125(2):244-8. PubMed ID: 22340553
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Increased risk of periprosthetic femur fractures associated with a unique cementless stem design.
    Watts CD; Abdel MP; Lewallen DG; Berry DJ; Hanssen AD
    Clin Orthop Relat Res; 2015 Jun; 473(6):2045-53. PubMed ID: 25502478
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Could larger diameter of 4th generation ceramic bearing decrease the rate of dislocation after THA?
    Lee YK; Ha YC; Jo WL; Kim TY; Jung WH; Koo KH
    J Orthop Sci; 2016 May; 21(3):327-31. PubMed ID: 26876620
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Mid-term results of the BIOLOX delta ceramic-on-ceramic total hip arthroplasty.
    Lee YK; Ha YC; Yoo JI; Jo WL; Kim KC; Koo KH
    Bone Joint J; 2017 Jun; 99-B(6):741-748. PubMed ID: 28566392
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Cementless Total Hip Arthroplasty With Metasul Bearings Provides Good Results in Active Young Patients: A Concise Followup.
    Delaunay CP; Putman S; Puliéro B; Bégin M; Migaud H; Bonnomet F
    Clin Orthop Relat Res; 2016 Oct; 474(10):2126-33. PubMed ID: 27278679
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Low Frequency of Early Complications With Dual-mobility Acetabular Cups in Cementless Primary THA.
    Chughtai M; Mistry JB; Diedrich AM; Jauregui JJ; Elmallah RK; Bonutti PM; Harwin SF; Malkani AL; Kolisek FR; Mont MA
    Clin Orthop Relat Res; 2016 Oct; 474(10):2181-7. PubMed ID: 27106128
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Alumina Delta-on-Alumina Delta Bearing in Cementless Total Hip Arthroplasty in Patients Aged <50 Years.
    Kim YH; Park JW; Kim JS
    J Arthroplasty; 2016 Oct; 31(10):2209-14. PubMed ID: 27067468
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 104.