These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

91 related articles for article (PubMed ID: 26127042)

  • 41. Indirect computed tomography venography of the lower extremities using single-source dual-energy computed tomography: advantage of low-kiloelectron volt monochromatic images.
    Kulkarni NM; Sahani DV; Desai GS; Kalva SP
    J Vasc Interv Radiol; 2012 Jul; 23(7):879-86. PubMed ID: 22633619
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Low-tube-voltage, high-tube-current multidetector abdominal CT: improved image quality and decreased radiation dose with adaptive statistical iterative reconstruction algorithm--initial clinical experience.
    Marin D; Nelson RC; Schindera ST; Richard S; Youngblood RS; Yoshizumi TT; Samei E
    Radiology; 2010 Jan; 254(1):145-53. PubMed ID: 20032149
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Toward clinical X-ray phase-contrast CT: demonstration of enhanced soft-tissue contrast in human specimen.
    Donath T; Pfeiffer F; Bunk O; Grünzweig C; Hempel E; Popescu S; Vock P; David C
    Invest Radiol; 2010 Jul; 45(7):445-52. PubMed ID: 20498610
    [TBL] [Abstract][Full Text] [Related]  

  • 44. The importance of spectral separation: an assessment of dual-energy spectral separation for quantitative ability and dose efficiency.
    Krauss B; Grant KL; Schmidt BT; Flohr TG
    Invest Radiol; 2015 Feb; 50(2):114-8. PubMed ID: 25373305
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Alpha image reconstruction (AIR): a new iterative CT image reconstruction approach using voxel-wise alpha blending.
    Hofmann C; Sawall S; Knaup M; Kachelrieß M
    Med Phys; 2014 Jun; 41(6):061914. PubMed ID: 24877825
    [TBL] [Abstract][Full Text] [Related]  

  • 46. A general framework of noise suppression in material decomposition for dual-energy CT.
    Petrongolo M; Dong X; Zhu L
    Med Phys; 2015 Aug; 42(8):4848-62. PubMed ID: 26233212
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Region-of-interest material decomposition from truncated energy-resolved CT.
    Schmidt TG; Pektas F
    Med Phys; 2011 Oct; 38(10):5657-66. PubMed ID: 21992382
    [TBL] [Abstract][Full Text] [Related]  

  • 48. The impact of the number of projections on image quality in Compton scatter tomography.
    Chighvinadze T; Pistorius S
    J Xray Sci Technol; 2015; 23(6):745-58. PubMed ID: 26756410
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Effect of X-ray tube parameters, iodine concentration, and patient size on image quality in pulmonary computed tomography angiography: a chest-phantom-study.
    Szucs-Farkas Z; Verdun FR; von Allmen G; Mini RL; Vock P
    Invest Radiol; 2008 Jun; 43(6):374-81. PubMed ID: 18496042
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Toward standardized quantitative image quality (IQ) assessment in computed tomography (CT): A comprehensive framework for automated and comparative IQ analysis based on ICRU Report 87.
    Pahn G; Skornitzke S; Schlemmer HP; Kauczor HU; Stiller W
    Phys Med; 2016 Jan; 32(1):104-15. PubMed ID: 26520485
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Combining low tube voltage and iterative reconstruction for contrast-enhanced CT imaging of the chest-initial clinical experience.
    Li Q; Yu H; Zhang L; Fan L; Liu SY
    Clin Radiol; 2013 May; 68(5):e249-53. PubMed ID: 23428340
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Realistic simulation of reduced-dose CT with noise modeling and sinogram synthesis using DICOM CT images.
    Won Kim C; Kim JH
    Med Phys; 2014 Jan; 41(1):011901. PubMed ID: 24387509
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Ultralow-dose chest computed tomography for pulmonary nodule detection: first performance evaluation of single energy scanning with spectral shaping.
    Gordic S; Morsbach F; Schmidt B; Allmendinger T; Flohr T; Husarik D; Baumueller S; Raupach R; Stolzmann P; Leschka S; Frauenfelder T; Alkadhi H
    Invest Radiol; 2014 Jul; 49(7):465-73. PubMed ID: 24598443
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Assessment of the hepatic veins in poor contrast conditions using dual energy CT: evaluation of a novel monoenergetic extrapolation software algorithm.
    Schabel C; Bongers M; Sedlmair M; Korn A; Grosse U; Mangold S; Claussen CD; Thomas C
    Rofo; 2014 Jun; 186(6):591-7. PubMed ID: 24756426
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Phase unwrapping in spectral X-ray differential phase-contrast imaging with an energy-resolving photon-counting pixel detector.
    Epple FM; Ehn S; Thibault P; Koehler T; Potdevin G; Herzen J; Pennicard D; Graafsma H; Noël PB; Pfeiffer F
    IEEE Trans Med Imaging; 2015 Mar; 34(3):816-23. PubMed ID: 25163054
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Diagnostic accuracy of coronary CT angiography: comparison of filtered back projection and iterative reconstruction with different strengths.
    Wang R; Schoepf UJ; Wu R; Nance JW; Lv B; Yang H; Li F; Lu D; Zhang Z
    J Comput Assist Tomogr; 2014; 38(2):179-84. PubMed ID: 24625599
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Image fusion in dual energy computed tomography for detection of hypervascular liver hepatocellular carcinoma: phantom and preliminary studies.
    Kim KS; Lee JM; Kim SH; Kim KW; Kim SJ; Cho SH; Han JK; Choi BI
    Invest Radiol; 2010 Mar; 45(3):149-57. PubMed ID: 20142749
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Photon counting spectral CT: improved material decomposition with K-edge-filtered x-rays.
    Shikhaliev PM
    Phys Med Biol; 2012 Mar; 57(6):1595-615. PubMed ID: 22398007
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Computational and human observer image quality evaluation of low dose, knowledge-based CT iterative reconstruction.
    Eck BL; Fahmi R; Brown KM; Zabic S; Raihani N; Miao J; Wilson DL
    Med Phys; 2015 Oct; 42(10):6098-111. PubMed ID: 26429285
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Characterization of adaptive statistical iterative reconstruction algorithm for dose reduction in CT: A pediatric oncology perspective.
    Brady SL; Yee BS; Kaufman RA
    Med Phys; 2012 Sep; 39(9):5520-31. PubMed ID: 22957619
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 5.