These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

236 related articles for article (PubMed ID: 26132722)

  • 1. Repetitive Implantable Cardioverter Defibrillator Shocks: What is the Mechanism?
    Iwasawa J; Miyazaki S; Hachiya H; Iesaka Y
    Pacing Clin Electrophysiol; 2015 Jul; 38(7):899-901. PubMed ID: 26132722
    [No Abstract]   [Full Text] [Related]  

  • 2. Repetitive Periodic Atrial Oversensing in a Cardiac Implantable Electrical Defibrillator at 35 Minutes and 50 Minutes Past the Hour: What Is the Diagnosis?
    Hu YL; Kaszala K; Huizar J; Ellenbogen KA; Tan AY
    Pacing Clin Electrophysiol; 2016 Sep; 39(9):1018-21. PubMed ID: 27356808
    [No Abstract]   [Full Text] [Related]  

  • 3. Inappropriate implantable cardioverter-defibrillator shocks and signal jammers: first report of a new interference.
    Amasyali B; Kilic A
    Int J Cardiol; 2014 Oct; 176(3):e96-7. PubMed ID: 25125021
    [No Abstract]   [Full Text] [Related]  

  • 4. How to prevent ICD shocks: part I.
    Buck S; Maass AH; Van Gelder IC
    Europace; 2008 Sep; 10(9):1110-1. PubMed ID: 18710855
    [No Abstract]   [Full Text] [Related]  

  • 5. How to prevent ICD shocks: part II.
    Buck S; Maass AH; Van Gelder IC
    Europace; 2008 Sep; 10(9):1126-9. PubMed ID: 18710856
    [No Abstract]   [Full Text] [Related]  

  • 6. A life-threatening arrhythmia induced by inappropriate activation of an implantable cardioverter defibrillator.
    Kadmon E; Kusniec J; Strasberg B
    Europace; 2009 Dec; 11(12):1716-8. PubMed ID: 19762330
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Inappropriate ICD discharges due to noise oversensing as the first sign of repetitive perforations of the right ventricular lead.
    Ueda-Tatsumoto A; Fukamizu S; Nishizaki M; Sakurada H; Hiraoka M
    Pacing Clin Electrophysiol; 2009 Nov; 32(11):1481-4. PubMed ID: 19712072
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Holiday Shocker: An Unusual Cause of Implantable Cardioverter Defibrillator Therapy.
    Carpenter V; Pugh PJ; Martin CA
    Pacing Clin Electrophysiol; 2015 Sep; 38(9):1114-6. PubMed ID: 25627877
    [No Abstract]   [Full Text] [Related]  

  • 9. Implantable cardioverter-defibrillator shock during physical activity: appropriate or inappropriate shock?
    Chemello D; Chin A; Morillo C; Divakaramenon S
    Pacing Clin Electrophysiol; 2013 May; 36(5):635-8. PubMed ID: 23127226
    [No Abstract]   [Full Text] [Related]  

  • 10. T-wave oversensing and inappropriate shocks: a case report.
    Srivathsan K; Scott LR; Altemose GT
    Europace; 2008 May; 10(5):552-5. PubMed ID: 18442965
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Renal artery thrombosis following an inappropriate implantable cardioverter defibrillator shock.
    Arias MA; DE LA Rosa C; Puchol A; Rodríguez-Padial L
    Pacing Clin Electrophysiol; 2012 Sep; 35(9):e263-4. PubMed ID: 21797905
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Single and inappropriate shock delivered out of tachycardia: device dysfunction?
    Fontenla A; Carrero D; Salguero R; López-Gil M; De Riva M; Arribas F
    Pacing Clin Electrophysiol; 2012 Jul; 35(7):884-6. PubMed ID: 22248372
    [No Abstract]   [Full Text] [Related]  

  • 13. A new mechanism for inappropriate therapy observed during recommended device software upgrade of a St Jude Medical Fortify ST™ implantable cardioverter-defibrillator.
    Sandgaard NC; Johansen JB
    Europace; 2014 Jan; 16(1):80. PubMed ID: 23858020
    [No Abstract]   [Full Text] [Related]  

  • 14. Pacing-dependency following implantable cardioverter-defibrillator shocks: a case report.
    Webber MR; Levings SL; Stiles MK
    J Electrocardiol; 2013; 46(2):142-4. PubMed ID: 23177276
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Multiple inappropriate defibrillator shocks due to insulation failure of a Biotronik Linox defibrillator lead with externalized conductor].
    Elfarra H; Moosdorf R; Rybinski L; Grimm W
    Herzschrittmacherther Elektrophysiol; 2016 Mar; 27(1):70-2. PubMed ID: 26848762
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Inappropriate shocks by subcutaneous defibrillator in a patient with arrhythmogenic right ventricular cardiomyopathy: problem fixed.
    Allocca G; Sitta N; Turiano G
    Europace; 2015 Jul; 17(7):1067. PubMed ID: 25842275
    [No Abstract]   [Full Text] [Related]  

  • 17. Inappropriate shocks or inappropriate programming? A review of Guidant's reconfirmation algorithm.
    Mansour F; Guash E; Berruezo A; Brugada J; Tolosana JM; Mont L
    Europace; 2009 Aug; 11(8):1120-2. PubMed ID: 19443435
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Postimplant Shocks in a Totally Subcutaneous Defibrillator: What Is the Mechanism?
    Arce-León Á; Arana-Rueda E; García-Riesco L; Guerrero-Márquez F; Pedrote A
    Pacing Clin Electrophysiol; 2015 Oct; 38(10):1225-7. PubMed ID: 25533853
    [No Abstract]   [Full Text] [Related]  

  • 19. Inappropriate shocks after implantable cardioverter-defibrillator for primary prevention in idiopathic cardiomyopathy: Independent determinants.
    Safak E; D'Ancona G; Ince H
    Int J Cardiol; 2016 Nov; 223():512-513. PubMed ID: 27552567
    [No Abstract]   [Full Text] [Related]  

  • 20. Automatic R-wave and impedance testing with the modern patient alert system to reduce inappropriate implantable cardioverter defibrillator shocks due to lead fracture.
    Chinushi M; Hosaka Y; Ikarashi N; Iijima K; Furushima H; Aizawa Y
    Europace; 2008 Jun; 10(6):738-40. PubMed ID: 18390874
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.