242 related articles for article (PubMed ID: 26134437)
1. Step-and-Shoot IMRT by Siemens Beams: An EPID Dosimetry Verification During Treatment.
Russo M; Piermattei A; Greco F; Azario L; Orlandini L; Zucca S; Cilla S; Menna S; Grusio M; Chiatti L; Fidanzio A
Technol Cancer Res Treat; 2016 Aug; 15(4):535-45. PubMed ID: 26134437
[TBL] [Abstract][Full Text] [Related]
2. An in-vivo dosimetry procedure for Elekta step and shoot IMRT.
Cilla S; Azario L; Greco F; Fidanzio A; Porcelli A; Grusio M; Macchia G; Morganti AG; Meluccio D; Piermattei A
Phys Med; 2014 Jun; 30(4):419-26. PubMed ID: 24361278
[TBL] [Abstract][Full Text] [Related]
3. Clinical experience with EPID dosimetry for prostate IMRT pre-treatment dose verification.
McDermott LN; Wendling M; van Asselen B; Stroom J; Sonke JJ; van Herk M; Mijnheer BJ
Med Phys; 2006 Oct; 33(10):3921-30. PubMed ID: 17089854
[TBL] [Abstract][Full Text] [Related]
4. aSi-EPID transit signal calibration for dynamic beams: a needful step for the IMRT in vivo dosimetry.
Greco F; Piermattei A; Azario L; Placidi L; Cilla S; Caivano R; Fusco V; Fidanzio A
Med Biol Eng Comput; 2013 Oct; 51(10):1137-45. PubMed ID: 23835663
[TBL] [Abstract][Full Text] [Related]
5. Integration between in vivo dosimetry and image guided radiotherapy for lung tumors.
Piermattei A; Cilla S; Grimaldi L; Sabatino D; Fidanzio A; Greco F; Mameli A; Balducci M; Mattiucci GC; Frascino V; Stimato G; Gaudino D; Ramella S; Trodella L; D'Onofrio G; Zini G; Macchia G; Digesu' C; Morganti AG; Clemente S; Cozzolino M; Pedicini P; Fusco V
Med Phys; 2009 Jun; 36(6):2206-14. PubMed ID: 19610309
[TBL] [Abstract][Full Text] [Related]
6. Quasi real time in vivo dosimetry for VMAT.
Fidanzio A; Porcelli A; Azario L; Greco F; Cilla S; Grusio M; Balducci M; Valentini V; Piermattei A
Med Phys; 2014 Jun; 41(6):062103. PubMed ID: 24877830
[TBL] [Abstract][Full Text] [Related]
7. Initial clinical experience with Epid-based in-vivo dosimetry for VMAT treatments of head-and-neck tumors.
Cilla S; Meluccio D; Fidanzio A; Azario L; Ianiro A; Macchia G; Digesù C; Deodato F; Valentini V; Morganti AG; Piermattei A
Phys Med; 2016 Jan; 32(1):52-8. PubMed ID: 26511150
[TBL] [Abstract][Full Text] [Related]
8. A Feasibility Study for in vivo Dosimetry Procedure in Routine Clinical Practice.
Falco MD; Giancaterino S; De Nicola A; Adorante N; De Lorenzo RG; Di Tommaso M; Vinciguerra A; Trignani M; Perrotti F; Allajbej A; Fidanzio A; Greco F; Grusio M; Genovesi D; Piermattei A
Technol Cancer Res Treat; 2018 Jan; 17():1533033818779201. PubMed ID: 29871570
[TBL] [Abstract][Full Text] [Related]
9. EPID-based in vivo dosimetry for stereotactic body radiotherapy of non-small cell lung tumors: Initial clinical experience.
Consorti R; Fidanzio A; Brainovich V; Mangiacotti F; De Spirito M; Mirri MA; Petrucci A
Phys Med; 2017 Oct; 42():157-161. PubMed ID: 29173910
[TBL] [Abstract][Full Text] [Related]
10. Treatment verification in the presence of inhomogeneities using EPID-based three-dimensional dose reconstruction.
van Elmpt WJ; Nijsten SM; Dekker AL; Mijnheer BJ; Lambin P
Med Phys; 2007 Jul; 34(7):2816-26. PubMed ID: 17821989
[TBL] [Abstract][Full Text] [Related]
11. EPID-based dosimetry to verify IMRT planar dose distribution for the aS1200 EPID and FFF beams.
Miri N; Keller P; Zwan BJ; Greer P
J Appl Clin Med Phys; 2016 Nov; 17(6):292-304. PubMed ID: 27929502
[TBL] [Abstract][Full Text] [Related]
12. Measurement-based Monte Carlo dose calculation system for IMRT pretreatment and on-line transit dose verifications.
Lin MH; Chao TC; Lee CC; Tung CJ; Yeh CY; Hong JH
Med Phys; 2009 Apr; 36(4):1167-75. PubMed ID: 19472622
[TBL] [Abstract][Full Text] [Related]
13. Overview of 3-year experience with large-scale electronic portal imaging device-based 3-dimensional transit dosimetry.
Mijnheer BJ; González P; Olaciregui-Ruiz I; Rozendaal RA; van Herk M; Mans A
Pract Radiat Oncol; 2015; 5(6):e679-87. PubMed ID: 26421834
[TBL] [Abstract][Full Text] [Related]
14. In aqua vivo EPID dosimetry.
Wendling M; McDermott LN; Mans A; Olaciregui-Ruiz Í; Pecharromán-Gallego R; Sonke JJ; Stroom J; van Herk M; Mijnheer BJ
Med Phys; 2012 Jan; 39(1):367-77. PubMed ID: 22225306
[TBL] [Abstract][Full Text] [Related]
15.
Kumar PS; Banerjee S; Arun Kumar ES; Srinivas C; Vadhiraja BM; Saxena PU; Ravichandran R; Kasturi DP
J Cancer Res Ther; 2018; 14(2):300-307. PubMed ID: 29516910
[TBL] [Abstract][Full Text] [Related]
16. Feasibility of portal dosimetry for flattening filter-free radiotherapy.
Chuter RW; Rixham PA; Weston SJ; Cosgrove VP
J Appl Clin Med Phys; 2016 Jan; 17(1):112-120. PubMed ID: 26894337
[TBL] [Abstract][Full Text] [Related]
17. Intensity-modulated radiation therapy dose verification using fluence and portal imaging device.
Sumida I; Yamaguchi H; Das IJ; Kizaki H; Aboshi K; Tsujii M; Yamada Y; Suzuki O; Seo Y; Isohashi F; Ogawa K
J Appl Clin Med Phys; 2016 Jan; 17(1):259-271. PubMed ID: 26894363
[TBL] [Abstract][Full Text] [Related]
18. A Monte Carlo based three-dimensional dose reconstruction method derived from portal dose images.
van Elmpt WJ; Nijsten SM; Schiffeleers RF; Dekker AL; Mijnheer BJ; Lambin P; Minken AW
Med Phys; 2006 Jul; 33(7):2426-34. PubMed ID: 16898445
[TBL] [Abstract][Full Text] [Related]
19. A novel approach to SBRT patient quality assurance using EPID-based real-time transit dosimetry : A step to QA with in vivo EPID dosimetry.
Moustakis C; Ebrahimi Tazehmahalleh F; Elsayad K; Fezeu F; Scobioala S
Strahlenther Onkol; 2020 Feb; 196(2):182-192. PubMed ID: 31925465
[TBL] [Abstract][Full Text] [Related]
20. Validation of a method for in vivo 3D dose reconstruction for IMRT and VMAT treatments using on-treatment EPID images and a model-based forward-calculation algorithm.
Van Uytven E; Van Beek T; McCowan PM; Chytyk-Praznik K; Greer PB; McCurdy BM
Med Phys; 2015 Dec; 42(12):6945-54. PubMed ID: 26632050
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]