These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

444 related articles for article (PubMed ID: 26136361)

  • 1. Topic controversies in the endoscopic management of malignant hilar strictures using metal stent: side-by-side versus stent-in-stent techniques.
    Moon JH; Rerknimitr R; Kogure H; Nakai Y; Isayama H
    J Hepatobiliary Pancreat Sci; 2015 Sep; 22(9):650-6. PubMed ID: 26136361
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Technique of reintervention for stent dysfunction in patients with malignant hilar biliary stricture.
    Okabe Y; Ishida Y; Ushijima T; Sugiyama G; Sata M
    Dig Endosc; 2013 May; 25 Suppl 2():90-3. PubMed ID: 23617657
    [TBL] [Abstract][Full Text] [Related]  

  • 3. High single-session success rate of endoscopic bilateral stent-in-stent placement with modified large cell Niti-S stents for malignant hilar biliary obstruction.
    Kogure H; Isayama H; Nakai Y; Tsujino T; Matsubara S; Yashima Y; Ito Y; Hamada T; Takahara N; Miyabayashi K; Mizuno S; Mohri D; Kawakubo K; Sasaki T; Yamamoto N; Hirano K; Sasahira N; Tada M; Koike K
    Dig Endosc; 2014 Jan; 26(1):93-9. PubMed ID: 23517109
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Metallic stents are more efficacious than plastic stents in unresectable malignant hilar biliary strictures: a randomized controlled trial.
    Mukai T; Yasuda I; Nakashima M; Doi S; Iwashita T; Iwata K; Kato T; Tomita E; Moriwaki H
    J Hepatobiliary Pancreat Sci; 2013 Feb; 20(2):214-22. PubMed ID: 22415652
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Current status and issues regarding biliary stenting in unresectable biliary obstruction.
    Itoi T; Sofuni A; Itokawa F; Tonozuka R; Ishii K
    Dig Endosc; 2013 May; 25 Suppl 2():63-70. PubMed ID: 23617652
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Percutaneous stent placement for malignant hilar biliary obstruction: side-by-side versus stent-in-stent technique.
    Zhou WZ; Liu S; Yang ZQ; Xian YT; Xu HD; Wu JZ; Shi HB
    BMC Gastroenterol; 2020 Jun; 20(1):174. PubMed ID: 32503426
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Clinical Outcomes of Bilateral Stent-in-Stent Placement Using Self-Expandable Metallic Stent for High-Grade Malignant Hilar Biliary Obstruction.
    Heo JY; Lee HS; Son JH; Lee SH; Bang S
    Yonsei Med J; 2018 Sep; 59(7):827-833. PubMed ID: 30091315
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Endoscopic bilateral deployment of multiple metallic stents for malignant hilar biliary strictures.
    Kato H; Tsutsumi K; Harada R; Okada H; Yamamoto K
    Dig Endosc; 2013 May; 25 Suppl 2():75-80. PubMed ID: 23617654
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Prospective comparison of endoscopic bilateral stent-in-stent versus stent-by-stent deployment for inoperable advanced malignant hilar biliary stricture.
    Lee TH; Moon JH; Choi JH; Lee SH; Lee YN; Paik WH; Jang DK; Cho BW; Yang JK; Hwangbo Y; Park SH
    Gastrointest Endosc; 2019 Aug; 90(2):222-230. PubMed ID: 30905729
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Endoscopic deployment of multiple JOSTENT SelfX is effective and safe in treatment of malignant hilar biliary strictures.
    Kawamoto H; Tsutsumi K; Harada R; Fujii M; Kato H; Hirao K; Kurihara N; Nakanishi T; Mizuno O; Ishida E; Ogawa T; Fukatsu H; Sakaguchi K
    Clin Gastroenterol Hepatol; 2008 Apr; 6(4):401-8. PubMed ID: 18328793
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Single-step simultaneous side-by-side placement of a self-expandable metallic stent with a 6-Fr delivery system for unresectable malignant hilar biliary obstruction: a feasibility study.
    Kawakubo K; Kawakami H; Kuwatani M; Kudo T; Abe Y; Kawahata S; Kubo K; Kubota Y; Sakamoto N
    J Hepatobiliary Pancreat Sci; 2015 Feb; 22(2):151-5. PubMed ID: 25345586
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Endoscopic bilateral metallic stenting for malignant hilar obstruction using newly designed stents.
    Kogure H; Isayama H; Kawakubo K; Sasaki T; Yamamoto N; Hirano K; Sasahira N; Tsujino T; Tada M; Koike K
    J Hepatobiliary Pancreat Sci; 2011 Sep; 18(5):653-7. PubMed ID: 21681649
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Y-shaped endoscopic bilateral metal stent placement for malignant hilar biliary obstruction: prospective long-term study.
    Hwang JC; Kim JH; Lim SG; Kim SS; Yoo BM; Cho SW
    Scand J Gastroenterol; 2011 Mar; 46(3):326-32. PubMed ID: 21082874
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Expandable metal stents for endoscopic bilateral stent-within-stent placement for malignant hilar biliary obstruction.
    Chahal P; Baron TH
    Gastrointest Endosc; 2010 Jan; 71(1):195-9. PubMed ID: 19945101
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Endoscopic biliary stenting for unresectable malignant hilar obstruction.
    Fukasawa M; Takano S; Shindo H; Takahashi E; Sato T; Enomoto N
    Clin J Gastroenterol; 2017 Dec; 10(6):485-490. PubMed ID: 29052124
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Small cell- versus large cell-sized metal stent in endoscopic bilateral stent-in-stent placement for malignant hilar biliary obstruction.
    Lee JM; Lee SH; Chung KH; Park JM; Paik WH; Woo SM; Lee WJ; Ryu JK; Kim YT
    Dig Endosc; 2015 Sep; 27(6):692-9. PubMed ID: 25708157
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Bilateral metal stents for hilar biliary obstruction using a 6Fr delivery system: outcomes following bilateral and side-by-side stent deployment.
    Law R; Baron TH
    Dig Dis Sci; 2013 Sep; 58(9):2667-72. PubMed ID: 23625287
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Management of acute cholangitis as a result of occlusion from a self-expandable metallic stent in patients with malignant distal and hilar biliary obstructions.
    Shiomi H; Matsumoto K; Isayama H
    Dig Endosc; 2017 Apr; 29 Suppl 2():88-93. PubMed ID: 28425663
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Endoscopic re-intervention after stent-in-stent versus side-by-side bilateral self-expandable metallic stent deployment.
    Iwai T; Kida M; Okuwaki K; Yamauchi H; Kaneko T; Hasegawa R; Watanabe M; Kurosu T; Imaizumi H; Koizumi W
    J Gastroenterol Hepatol; 2022 Jun; 37(6):1060-1066. PubMed ID: 35261069
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Predictive factors for the failure of endoscopic stent-in-stent self-expandable metallic stent placement to treat malignant hilar biliary obstruction.
    Sugimoto M; Takagi T; Suzuki R; Konno N; Asama H; Watanabe K; Nakamura J; Kikuchi H; Waragai Y; Takasumi M; Sato Y; Hikichi T; Ohira H
    World J Gastroenterol; 2017 Sep; 23(34):6273-6280. PubMed ID: 28974893
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 23.