These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

139 related articles for article (PubMed ID: 26137880)

  • 1. New multimodal data obtained in-vivo from a single ultra-miniature transducer.
    Clark TM; Malpas SC; McCormick D; Guild SJ; Budgett DM
    Biomed Microdevices; 2015 Aug; 17(4):72. PubMed ID: 26137880
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Implantable electrolyte conductance-based pressure sensing catheter, II. Device construction and testing.
    Tan R; Benharash P; Schulam P; Schmidt JJ
    Biomed Microdevices; 2013 Dec; 15(6):1035-41. PubMed ID: 23868117
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Long term assessment of blood pressure transducer drift in rhesus monkeys chronically instrumented with telemetry implants.
    Regan HK; Lynch JJ; Regan CP
    J Pharmacol Toxicol Methods; 2009; 59(1):35-8. PubMed ID: 18983927
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Development of passive telemetry system for intracranial pressure measurement with corrector of errors caused by temperature variation].
    Magara M; Saitoh Y; Kiryu T; Makino H; Tanaka R
    Iyodenshi To Seitai Kogaku; 1989 Mar; 27(1):35-44. PubMed ID: 2754863
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Implementation of multichannel sensors for remote biomedical measurements in a microsystems format.
    Johannessen EA; Wang L; Cui L; Tang TB; Ahmadian M; Astaras A; Reid SW; Yam PS; Murray AF; Flynn BW; Beaumont SP; Cumming DR; Cooper JM
    IEEE Trans Biomed Eng; 2004 Mar; 51(3):525-35. PubMed ID: 15000383
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Miniature all-fiber Fabry-Perot sensor for simultaneous measurement of pressure and temperature.
    Pevec S; Donlagic D
    Appl Opt; 2012 Jul; 51(19):4536-41. PubMed ID: 22772127
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Technology and application of ultraminiature catheter pressure transducers.
    Zimmer HG; Millar HD
    Can J Cardiol; 1998 Oct; 14(10):1259-66. PubMed ID: 9852939
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Flexible sensor for blood pressure measurement.
    Sepúlveda AT; Pontes AJ; Viana JC; de Villoria RG; Fachin F; Wardle BL; Rocha LA
    Annu Int Conf IEEE Eng Med Biol Soc; 2011; 2011():512-5. PubMed ID: 22254360
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A portable microsystem-based telemetric pressure and temperature measurement unit.
    Flick BB; Orglmeister R
    IEEE Trans Biomed Eng; 2000 Jan; 47(1):12-6. PubMed ID: 10646273
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A telemetric pressure sensor system for biomedical applications.
    Ginggen A; Tardy Y; Crivelli R; Bork T; Renaud P
    IEEE Trans Biomed Eng; 2008 Apr; 55(4):1374-81. PubMed ID: 18390328
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Feasibility of prosthetic posture sensing via injectable electronic modules.
    Tan W; Loeb GE
    IEEE Trans Neural Syst Rehabil Eng; 2007 Jun; 15(2):295-309. PubMed ID: 17601200
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Evaluation of blood pressure measurement using a miniature blood pressure transmitter with jacketed external telemetry in cynomolgus monkeys.
    McMahon C; Mitchell AZ; Klein JL; Jenkins AC; Sarazan RD
    J Pharmacol Toxicol Methods; 2010; 62(2):127-35. PubMed ID: 20558308
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Maintained functionality of an implantable radiotelemetric blood pressure and heart rate sensor after magnetic resonance imaging in rats.
    Nölte I; Gorbey S; Boll H; Figueiredo G; Groden C; Lemmer B; Brockmann MA
    Physiol Meas; 2011 Dec; 32(12):1941-51. PubMed ID: 22047995
    [TBL] [Abstract][Full Text] [Related]  

  • 14. New telemetry device for the measurement of gastrointestinal motility in rats and comparison with standard equipment.
    Meile T; Zieker D; Königsrainer A; Glatzle J
    Int Surg; 2015 Apr; 100(4):755-60. PubMed ID: 25875561
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Implantable 9-channel telemetry system for in vivo load measurements with orthopedic implants.
    Graichen F; Arnold R; Rohlmann A; Bergmann G
    IEEE Trans Biomed Eng; 2007 Feb; 54(2):253-61. PubMed ID: 17278582
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Biocompatibility of a lab-on-a-pill sensor in artificial gastrointestinal environments.
    Johannessen EA; Wang L; Wyse C; Cumming DR; Cooper JM
    IEEE Trans Biomed Eng; 2006 Nov; 53(11):2333-40. PubMed ID: 17073339
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A 10-Fr ultrasound catheter with integrated micromotor for 4-D intracardiac echocardiography.
    Lee W; Griffin W; Wildes D; Buckley D; Topka T; Chodakauskas T; Langer M; Calisti S; Bergstøl S; Malacrida JP; Lanteri F; Maffre J; McDaniel B; Shivkumar K; Cummings J; Callans D; Silvestry F; Packer D
    IEEE Trans Ultrason Ferroelectr Freq Control; 2011 Jul; 58(7):1478-91. PubMed ID: 21768032
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Chronic measurement of left ventricular pressure in freely moving rats.
    Stehlin E; Malpas SC; Budgett DM; Barrett CJ; McCormick D; Whalley G; Fu F; Beil M; Rigel DF; Guild SJ
    J Appl Physiol (1985); 2013 Dec; 115(11):1672-82. PubMed ID: 24114699
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Continuous amperometric monitoring of subcutaneous oxygen in rabbit by telemetry.
    Ward WK; Wood MD; Slobodzian EP
    J Med Eng Technol; 2002; 26(4):158-67. PubMed ID: 12396331
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Multi-sensor radiotelemetry system for intestinal motility measurement.
    Biao H; Guozheng Y; Peng Z
    J Med Eng Technol; 2009; 33(1):66-71. PubMed ID: 19116855
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.