These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

132 related articles for article (PubMed ID: 26140008)

  • 1. Enteral metallic stenting by balloon enteroscopy for obstruction of surgically reconstructed intestine.
    Nakahara K; Okuse C; Matsumoto N; Suetani K; Morita R; Michikawa Y; Ozawa S; Hosoya K; Kobayashi S; Otsubo T; Itoh F
    World J Gastroenterol; 2015 Jun; 21(24):7589-93. PubMed ID: 26140008
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Ultrathin endoscope-assisted self-expandable metallic stent placement following initial unsuccessful attempt in malignant upper gastrointestinal obstruction.
    Park SW; Lee H; Park JC; Shin SK; Lee SK; Lee YC
    Dig Endosc; 2014 Mar; 26(2):200-7. PubMed ID: 23751083
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Preliminary study of enteroscopy-guided, self-expandable metal stent placement for malignant small bowel obstruction.
    Lee H; Park JC; Shin SK; Lee SK; Lee YC
    J Gastroenterol Hepatol; 2012 Jul; 27(7):1181-6. PubMed ID: 22414138
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Palliation of malignant gastric outlet obstruction with simultaneous endoscopic insertion of afferent and efferent jejunal limb enteral stents in patients with recurrent malignancy.
    Soo I; Gerdes H; Markowitz AJ; Mendelsohn RB; Ludwig E; Shah P; Schattner MA
    Surg Endosc; 2016 Feb; 30(2):521-525. PubMed ID: 26091983
    [TBL] [Abstract][Full Text] [Related]  

  • 5. SEMS vs cSEMS in duodenal and small bowel obstruction: high risk of migration in the covered stent group.
    Waidmann O; Trojan J; Friedrich-Rust M; Sarrazin C; Bechstein WO; Ulrich F; Zeuzem S; Albert JG
    World J Gastroenterol; 2013 Oct; 19(37):6199-206. PubMed ID: 24115817
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Severity of initial stent angulation predicts reintervention after successful palliative enteral stenting for malignant luminal obstruction.
    Lee EY; Bourke MJ; Williams SJ; Alrubaie A; Kwan V; Bailey AA; Lynch PM; Loh SM
    J Gastroenterol Hepatol; 2011 Mar; 26(3):484-91. PubMed ID: 21155877
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Combined use of single-balloon enteroscope and colonoscope for self-expandable metal stent placement in patients with malignant small intestinal obstruction: a single-center comparative clinical observation.
    Zhang YF; Ning SB; Li BR; Zhang J; Li J; Tang J; Zhu M; Jin XW; Zhao Q; Mao GP
    J Huazhong Univ Sci Technolog Med Sci; 2017 Jun; 37(3):357-361. PubMed ID: 28585148
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Safety and efficacy of self-expandable metallic stents in malignant small bowel obstructions.
    Tsuboi A; Kuwai T; Nishimura T; Iio S; Mori T; Imagawa H; Yamaguchi T; Yamaguchi A; Kouno H; Kohno H
    World J Gastroenterol; 2016 Oct; 22(40):9022-9027. PubMed ID: 27833393
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Combined endoscopic stent-in-stent placement for malignant biliary and duodenal obstruction by using a new duodenal metal stent (with videos).
    Moon JH; Choi HJ; Ko BM; Koo HC; Hong SJ; Cheon YK; Cho YD; Lee MS; Shim CS
    Gastrointest Endosc; 2009 Oct; 70(4):772-7. PubMed ID: 19595319
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Fluoroscopy-Guided Peroral Placement of a Self-Expandable Metallic Stent for Malignant Jejunal Obstruction in a Non-surgically Altered Stomach.
    Wang Z; Park JH; Kim KY; Choi J; Hu H; Bekheet N; Yoon SH; Song HY
    Cardiovasc Intervent Radiol; 2019 Jan; 42(1):145-149. PubMed ID: 30088059
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Spiral-enteroscopy-assisted enteral stent placement for palliation of malignant small-bowel obstruction (with video).
    Lennon AM; Chandrasekhara V; Shin EJ; Okolo PI
    Gastrointest Endosc; 2010 Feb; 71(2):422-5. PubMed ID: 19896664
    [No Abstract]   [Full Text] [Related]  

  • 12. Endoscopic placement of self-expandable metal stents for malignant colonic obstruction: long-term outcomes and complication factors.
    Small AJ; Coelho-Prabhu N; Baron TH
    Gastrointest Endosc; 2010 Mar; 71(3):560-72. PubMed ID: 20189515
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Self-expandable metallic stents in the palliation of rectosigmoidal carcinoma: a follow-up study.
    Tack J; Gevers AM; Rutgeerts P
    Gastrointest Endosc; 1998 Sep; 48(3):267-71. PubMed ID: 9744602
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Fluoroscopically guided placement of self-expandable metallic stents and stent-grafts in the treatment of acute malignant colorectal obstruction.
    Kim H; Kim SH; Choi SY; Lee KH; Won JY; Lee DY; Lee JT
    J Vasc Interv Radiol; 2008 Dec; 19(12):1709-16. PubMed ID: 18845454
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Impact of a Newly Developed Short Double-Balloon Enteroscope on Stent Placement in Patients with Surgically Altered Anatomies.
    Tsutsumi K; Kato H; Okada H
    Gut Liver; 2017 Mar; 11(2):306-311. PubMed ID: 28208009
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Palliation of gastric outlet obstruction and proximal small bowel obstruction with self-expandable metal stents: a single center series.
    Mosler P; Mergener KD; Brandabur JJ; Schembre DB; Kozarek RA
    J Clin Gastroenterol; 2005 Feb; 39(2):124-8. PubMed ID: 15681907
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Palliative self-expandable metal stents for acute malignant colorectal obstruction: clinical outcomes and risk factors for complications.
    Han JP; Hong SJ; Kim SH; Choi JH; Jung HJ; Cho YH; Ko BM; Lee MS
    Scand J Gastroenterol; 2014 Aug; 49(8):967-73. PubMed ID: 24874189
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of outcomes among secondary covered metallic, uncovered metallic, and plastic biliary stents in treating occluded primary metallic stents in malignant distal biliary obstruction.
    Cho JH; Jeon TJ; Park JY; Kim HM; Kim YJ; Park SW; Chung JB; Song SY; Bang S
    Surg Endosc; 2011 Feb; 25(2):475-82. PubMed ID: 20602138
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Efficacy and Long-Term Outcomes of Side-by-Side Self-Expandable Metal Stent Placement Using a 2-Channel Endoscope for Unresectable Malignant Hilar Biliary Obstruction Occurring After Billroth II Reconstruction (with Video).
    Okuwaki K; Yamauchi H; Kida M; Imaizumi H; Iwai T; Matsumoto T; Kawaguchi Y; Uehara K; Nakatani S; Koizumi W
    Dig Dis Sci; 2018 Jun; 63(6):1641-1646. PubMed ID: 29557076
    [TBL] [Abstract][Full Text] [Related]  

  • 20. An endoscopic technique for treating symptomatic distal jejunum obstruction by leaving the overtube in place.
    Pérez-Cuadrado E; Carballo F; Latorre R; Soria F; López-Albors O
    Rev Esp Enferm Dig; 2013 Feb; 105(2):107-9. PubMed ID: 23659511
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.