These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

67 related articles for article (PubMed ID: 2614140)

  • 1. [Monitoring of spinal cord function during aortic interruption--with special reference to the efficacy of cerebral cortex stimulation].
    Hosokawa S; Mizuno S; Abe M; Tanaka M; Takeuchi E
    Nihon Kyobu Geka Gakkai Zasshi; 1989 May; 37(5):863-5. PubMed ID: 2614140
    [No Abstract]   [Full Text] [Related]  

  • 2. [The prevention of spinal cord ischemia during surgery of the thoracic aorta utilizing evoked spinal cord potential--evoked spinal cord potential versus somatosensory evoked potential in spinal ischemic changes].
    Matsui Y; Goh K; Okude J; Sakuma M; Yasuda K; Tanabe T
    Nihon Kyobu Geka Gakkai Zasshi; 1986 Feb; 34(2):172-9. PubMed ID: 3722914
    [No Abstract]   [Full Text] [Related]  

  • 3. [Intraoperative ESCP (evoked spinal cord potential) monitoring for detection of paraplegia following thoracic aorta cross-clamping].
    Kikuchi S; Kazui T; Sasaki T; Sasaki A; Morishita K; Inoue N; Yokoyama H; Yamada O; Komatsu S
    Nihon Kyobu Geka Gakkai Zasshi; 1987 Nov; 35(11):1964-73. PubMed ID: 3446711
    [No Abstract]   [Full Text] [Related]  

  • 4. [Study on prevention of paraplegia during occlusion blockade of the thoracic aorta--examination of the evoked potential in the motor nerve induced by stimulation of the motor area of cerebral cortex].
    Hamaya H
    Nihon Kyobu Geka Gakkai Zasshi; 1993 Aug; 41(8):1347-56. PubMed ID: 8360536
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Monitoring of spinal cord ischemia using evoked motor nerve action potentials by motor area stimulation].
    Hamaya H; Kikuchi S; Kazui T; Komatsu S
    Nihon Geka Gakkai Zasshi; 1988 Feb; 89(2):311. PubMed ID: 3362136
    [No Abstract]   [Full Text] [Related]  

  • 6. Monitoring of anterior cervical spinal cord function.
    Shinomiya K; Mochida K; Komori H; Mutoh N; Okawa A
    J Spinal Disord; 1996 Jun; 9(3):187-94. PubMed ID: 8854272
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effect of spinal cord ischemia on compound muscle action potentials and spinal evoked potentials following spinal cord stimulation in the dog.
    Machida M; Yamada T; Ross M; Kimura J; Hitchon P
    J Spinal Disord; 1990 Dec; 3(4):345-52. PubMed ID: 2134449
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Spinal cord evoked potential].
    Fukaya C; Katayama Y
    Masui; 2006 Mar; 55(3):322-9. PubMed ID: 16541781
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Efferent spinal evoked potentials by transcranial magnetic stimulation in dog].
    Kajihara H
    Nihon Seikeigeka Gakkai Zasshi; 1995 Oct; 69(10):1050-63. PubMed ID: 8551090
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Intraoperative identification of vessels critical to spinal cord blood supply--use of somatosensory evoked potentials.
    Laschinger JC; Cunningham JN; Nathan IM; Krieger K; Isom OW; Spencer FC
    Curr Surg; 1984; 41(2):107-9. PubMed ID: 6723354
    [No Abstract]   [Full Text] [Related]  

  • 11. [Experimental and clinical studies of the evoked electrospinogram for monitoring spinal cord function (author's transl)].
    Yasukawa K
    Nihon Seikeigeka Gakkai Zasshi; 1980 Dec; 54(12):1661-77. PubMed ID: 7288224
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [The effect of anesthetic agents on descending spinal cord evoked potential and the compound muscle action potentials elicited by stimulation at the cerebral motor cortex and the spinal cord].
    Toda Y
    Nihon Seikeigeka Gakkai Zasshi; 1992 Apr; 66(4):279-90. PubMed ID: 1593199
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Transcranial stimulation of the motor cortex to produce motor-evoked potentials.
    Levy WJ
    Med Instrum; 1987 Oct; 21(5):248-54. PubMed ID: 3683251
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Correlation of motor-evoked potential response to ischemic spinal cord damage.
    Reuter DG; Tacker WA; Badylak SF; Voorhees WD; Konrad PE
    J Thorac Cardiovasc Surg; 1992 Aug; 104(2):262-72. PubMed ID: 1495288
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Noncortical origins of the spinal motor evoked potential in rats.
    Zappulla RA; Hollis P; Ryder J; Moore FM; Adamson J; Moustakis W; Malis LI
    Neurosurgery; 1988 May; 22(5):846-52. PubMed ID: 3380273
    [TBL] [Abstract][Full Text] [Related]  

  • 16. "Backfiring" in spinal cord monitoring. High thoracic spinal cord stimulation evokes sciatic response by antidromic sensory pathway conduction, not motor tract conduction.
    Su CF; Haghighi SS; Oro JJ; Gaines RW
    Spine (Phila Pa 1976); 1992 May; 17(5):504-8. PubMed ID: 1621148
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Influence of anesthetic agents on intraspinal evoked potentials].
    Iida H; Tanahashi T; Ishiyama T; Uematsu H; Yamamoto M
    Masui; 1988 Feb; 37(2):169-75. PubMed ID: 3373726
    [No Abstract]   [Full Text] [Related]  

  • 18. [The prevention of spinal cord ischemia during the operation on the thoracic aorta utilizing the evoked spinal cord potential (ESP)].
    Matsui Y
    Nihon Geka Gakkai Zasshi; 1986 Oct; 87(10):1344-51. PubMed ID: 3796579
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Motor system monitoring during joint replacement operations.
    Schoenfeldt R; Groce R; Laurenzi B
    Neurosurgery; 1987 Jan; 20(1):197-8. PubMed ID: 3808264
    [No Abstract]   [Full Text] [Related]  

  • 20. Cold saline injection attenuates motor-evoked potential in the spinal cord by cortical electrical stimulation in the dog.
    Kumagai H; Sugawara Y; Isaka M; Okada K; Orihashi K; Sueda T
    Hiroshima J Med Sci; 2005 Sep; 54(3):77-82. PubMed ID: 16180700
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.