These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

244 related articles for article (PubMed ID: 26145185)

  • 1. MRI of the cervical spine with 3D gradient echo sequence at 3 T: initial experience.
    Xiao L; Siu CW; Yeung K; Leung A; Yuen MK; Wong YC
    Clin Radiol; 2015 Sep; 70(9):926-31. PubMed ID: 26145185
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Comparison of three-dimensional gradient echo, turbo spin echo and steady-state gradient echo sequences in axial MRI examination of the cervical spine].
    Mahmutyazicioğlu K; Ozdemir H; Savranlar A; Ozer T; Erdem O; Erdem Z; Gündoğdu S
    Tani Girisim Radyol; 2003 Dec; 9(4):432-8. PubMed ID: 14730951
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Qualitative and quantitative assessment of wrist MRI at 3.0T: comparison between isotropic 3D turbo spin echo and isotropic 3D fast field echo and 2D turbo spin echo.
    Jung JY; Yoon YC; Jung JY; Choe BK
    Acta Radiol; 2013 Apr; 54(3):284-91. PubMed ID: 23319720
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Three-dimensional isotropic T2-weighted cervical MRI at 3T: comparison with two-dimensional T2-weighted sequences.
    Kwon JW; Yoon YC; Choi SH
    Clin Radiol; 2012 Feb; 67(2):106-13. PubMed ID: 22142499
    [TBL] [Abstract][Full Text] [Related]  

  • 5. 3D isotropic turbo spin-echo intermediate-weighted sequence with refocusing control in knee imaging: comparison study with 3D isotropic fast-field echo sequence.
    Seo JM; Yoon YC; Kwon JW
    Acta Radiol; 2011 Dec; 52(10):1119-24. PubMed ID: 22144425
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparison of two-dimensional gradient echo, turbo spin echo and two-dimensional turbo gradient spin echo sequences in MRI of the cervical spinal cord anatomy.
    Held P; Seitz J; Fründ R; Nitz W; Lenhart M; Geissler A
    Eur J Radiol; 2001 Apr; 38(1):64-71. PubMed ID: 11287168
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Magnetic resonance imaging of the cervical spine: comparison of 2D T2-weighted turbo spin echo, 2D T2*weighted gradient-recalled echo and 3D T2-weighted variable flip-angle turbo spin echo sequences.
    Meindl T; Wirth S; Weckbach S; Dietrich O; Reiser M; Schoenberg SO
    Eur Radiol; 2009 Mar; 19(3):713-21. PubMed ID: 18813933
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Uterine tumors: comparison of 3D versus 2D T2-weighted turbo spin-echo MR imaging at 3.0 T--initial experience.
    Hori M; Kim T; Onishi H; Ueguchi T; Tatsumi M; Nakamoto A; Tsuboyama T; Tomoda K; Tomiyama N
    Radiology; 2011 Jan; 258(1):154-63. PubMed ID: 21045182
    [TBL] [Abstract][Full Text] [Related]  

  • 9. MRI of the lumbar spine: comparison of 3D isotropic turbo spin-echo SPACE sequence versus conventional 2D sequences at 3.0 T.
    Lee S; Jee WH; Jung JY; Lee SY; Ryu KS; Ha KY
    Acta Radiol; 2015 Feb; 56(2):174-81. PubMed ID: 24553584
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Three-dimensional fluid-attenuated inversion recovery sequence for visualisation of subthalamic nucleus for deep brain stimulation in Parkinson's disease.
    Heo YJ; Kim SJ; Kim HS; Choi CG; Jung SC; Lee JK; Lee CS; Chung SJ; Cho SH; Lee GR
    Neuroradiology; 2015 Sep; 57(9):929-35. PubMed ID: 26156865
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Three-Dimensional CAIPIRINHA SPACE TSE for 5-Minute High-Resolution MRI of the Knee.
    Fritz J; Fritz B; Thawait GG; Meyer H; Gilson WD; Raithel E
    Invest Radiol; 2016 Oct; 51(10):609-17. PubMed ID: 27187045
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Study of comparing the multiple MR sequenc in the articular cartilage of knee joint].
    Gu F; Zhang XZ
    Zhonghua Yi Xue Za Zhi; 2008 Jan; 88(4):245-9. PubMed ID: 18361835
    [TBL] [Abstract][Full Text] [Related]  

  • 13. MR imaging of the inner ear and cerebellopontine angle: comparison of three-dimensional and two-dimensional sequences.
    Czerny C; Rand T; Gstoettner W; Woelfl G; Imhof H; Trattnig S
    AJR Am J Roentgenol; 1998 Mar; 170(3):791-6. PubMed ID: 9490977
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Low flip angle gradient echo magnetic resonance imaging of the cervical spine at 0.3 tesla.
    Holtås S; Ståhlberg F; Nilsson H; Larsson EM; Ericsson A
    Acta Radiol; 1989; 30(4):343-8. PubMed ID: 2775593
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Knee derangements: comparison of isotropic 3D fast spin-echo, isotropic 3D balanced fast field-echo, and conventional 2D fast spin-echo MR imaging.
    Jung JY; Yoon YC; Kim HR; Choe BK; Wang JH; Jung JY
    Radiology; 2013 Sep; 268(3):802-13. PubMed ID: 23533289
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of diagnostic value and T2-weighted three-dimensional isotropic turbo spin-echo (3D-SPACE) image quality in comparison with T2-weighted two-dimensional turbo spin-echo (2D-TSE) sequences in lumbar spine MR imaging.
    Hossein J; Fariborz F; Mehrnaz R; Babak R
    Eur J Radiol Open; 2019; 6():36-41. PubMed ID: 30619918
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Preliminary clinical experience at 3 T with a 3D T2-weighted sequence compared with multiplanar 2D for evaluation of the female pelvis.
    Hecht EM; Yitta S; Lim RP; Fitzgerald EF; Storey P; Babb JS; Bani-Baker KO; Bennett GL
    AJR Am J Roentgenol; 2011 Aug; 197(2):W346-52. PubMed ID: 21785064
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Comparison between pig lumbar zypapophyseal joint cartilage acquired from multiple magnetic resonance image sequences and gross specimens].
    Liao H; Yu W; Wang W; Liao Y
    Zhong Nan Da Xue Xue Bao Yi Xue Ban; 2010 Oct; 35(10):1064-72. PubMed ID: 21051831
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Comparison of T2-weighted turbo spin-echo and ultrafast HASTE sequence in the diagnosis of cervical myelopathies and spinal stenoses and static and kinematic MRT of the spine].
    Muhle C; Metzner J; Brinkmann G; Kühn B; Bischoff L; Hutzelmann A; Wesner F; Heller M
    Rofo; 1997 Nov; 167(5):467-73. PubMed ID: 9440891
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Driven equilibrium (drive) MR imaging of the cranial nerves V-VIII: comparison with the T2-weighted 3D TSE sequence.
    Ciftci E; Anik Y; Arslan A; Akansel G; Sarisoy T; Demirci A
    Eur J Radiol; 2004 Sep; 51(3):234-40. PubMed ID: 15294330
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.