These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

65 related articles for article (PubMed ID: 26148623)

  • 1. Living with the Elekta Compact: Limitations and ways around them.
    Goswami J; Mallik S; Adhikary A; Das S; Pal B
    J Cancer Res Ther; 2015; 11(2):479-81. PubMed ID: 26148623
    [TBL] [Abstract][Full Text] [Related]  

  • 2. 3D-conformal-intensity modulated radiotherapy with compensators for head and neck cancer: clinical results of normal tissue sparing.
    Wendt TG; Abbasi-Senger N; Salz H; Pinquart I; Koscielny S; Przetak SM; Wiezorek T
    Radiat Oncol; 2006 Jun; 1():18. PubMed ID: 16790059
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Simultaneous integrated boost intensity-modulated radiotherapy for locally advanced head-and-neck squamous cell carcinomas: II--clinical results.
    Lauve A; Morris M; Schmidt-Ullrich R; Wu Q; Mohan R; Abayomi O; Buck D; Holdford D; Dawson K; Dinardo L; Reiter E
    Int J Radiat Oncol Biol Phys; 2004 Oct; 60(2):374-87. PubMed ID: 15380569
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Preservation of oral health-related quality of life and salivary flow rates after inverse-planned intensity- modulated radiotherapy (IMRT) for head-and-neck cancer.
    Parliament MB; Scrimger RA; Anderson SG; Kurien EC; Thompson HK; Field GC; Hanson J
    Int J Radiat Oncol Biol Phys; 2004 Mar; 58(3):663-73. PubMed ID: 14967418
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Static and rotational intensity modulated techniques for head-neck cancer radiotherapy: a planning comparison.
    Broggi S; Perna L; Bonsignore F; Rinaldin G; Fiorino C; Chiara A; Frigerio C; Butti I; Sangalli G; Dell'Oca I; Di Muzio N; Cattaneo GM; Declich F
    Phys Med; 2014 Dec; 30(8):973-9. PubMed ID: 25113943
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Assessing the feasibility of volumetric-modulated arc therapy using simultaneous integrated boost (SIB-VMAT): An analysis for complex head-neck, high-risk prostate and rectal cancer cases.
    Cilla S; Deodato F; Digesù C; Macchia G; Picardi V; Ferro M; Sallustio G; De Spirito M; Piermattei A; Morganti AG
    Med Dosim; 2014; 39(1):108-16. PubMed ID: 24342167
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparing 3DCRT and inversely optimized IMRT planning for head and neck cancer: equivalence between step-and-shoot and sliding window techniques.
    Longobardi B; De Martin E; Fiorino C; Dell'oca I; Broggi S; Cattaneo GM; Calandrino R
    Radiother Oncol; 2005 Nov; 77(2):148-56. PubMed ID: 16260056
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Dependence of achievable plan quality on treatment technique and planning goal refinement: a head-and-neck intensity modulated radiation therapy application.
    Qi XS; Ruan D; Lee SP; Pham A; Kupelian P; Low DA; Steinberg M; Demarco J
    Int J Radiat Oncol Biol Phys; 2015 Mar; 91(4):817-24. PubMed ID: 25752396
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A quantitative study of IMRT delivery effects in commercial planning systems for the case of oesophagus and prostate tumours.
    Seco J; Clark CH; Evans PM; Webb S
    Br J Radiol; 2006 May; 79(941):401-8. PubMed ID: 16632620
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Obtaining normal tissue constraints using intensity modulated radiotherapy (IMRT) in patients with oral cavity, oropharyngeal, and laryngeal carcinoma.
    Skinner WK; Muse ED; Yaparpalvi R; Guha C; Garg MK; Kalnicki S
    Med Dosim; 2009; 34(4):279-84. PubMed ID: 19854386
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A comparison of forward and inverse planned conformal, multi segment and intensity modulated radiotherapy for the treatment of prostate and pelvic nodes.
    Vaarkamp J; Adams EJ; Warrington AP; Dearnaley DP
    Radiother Oncol; 2004 Oct; 73(1):65-72. PubMed ID: 15465148
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Experience-based quality control of clinical intensity-modulated radiotherapy planning.
    Moore KL; Brame RS; Low DA; Mutic S
    Int J Radiat Oncol Biol Phys; 2011 Oct; 81(2):545-51. PubMed ID: 21277097
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Intensity modulated radiotherapy for high risk prostate cancer based on sentinel node SPECT imaging for target volume definition.
    Ganswindt U; Paulsen F; Corvin S; Eichhorn K; Glocker S; Hundt I; Birkner M; Alber M; Anastasiadis A; Stenzl A; Bares R; Budach W; Bamberg M; Belka C
    BMC Cancer; 2005 Jul; 5():91. PubMed ID: 16048656
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Treatment plan comparison between helical tomotherapy and MLC-based IMRT using radiobiological measures.
    Mavroidis P; Ferreira BC; Shi C; Lind BK; Papanikolaou N
    Phys Med Biol; 2007 Jul; 52(13):3817-36. PubMed ID: 17664579
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Three-dimensional conformal radiotherapy for locally advanced (Stage II and worse) head-and-neck cancer: dosimetric and clinical evaluation.
    Portaluri M; Fucilli FI; Castagna R; Bambace S; Pili G; Tramacere F; Russo D; Francavilla MC
    Int J Radiat Oncol Biol Phys; 2006 Nov; 66(4):1036-43. PubMed ID: 16750321
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Swallowing-sparing intensity-modulated radiotherapy for head and neck cancer patients: treatment planning optimization and clinical introduction.
    van der Laan HP; Gawryszuk A; Christianen ME; Steenbakkers RJ; Korevaar EW; Chouvalova O; Wopken K; Bijl HP; Langendijk JA
    Radiother Oncol; 2013 Jun; 107(3):282-7. PubMed ID: 23742959
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Intensity-modulated radiation therapy for pancreatic and prostate cancer using pulsed low-dose rate delivery techniques.
    Li J; Lang J; Wang P; Kang S; Lin MH; Chen X; Chen F; Guo M; Chen L; Ma CM
    Med Dosim; 2014; 39(4):330-6. PubMed ID: 25087084
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Hypothyroidism after 3-dimensional conformal radiotherapy and intensity-modulated radiotherapy for head and neck cancers: prospective data from 2 randomized controlled trials.
    Murthy V; Narang K; Ghosh-Laskar S; Gupta T; Budrukkar A; Agrawal JP
    Head Neck; 2014 Nov; 36(11):1573-80. PubMed ID: 23996654
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Distinct effects of rectum delineation methods in 3D-conformal vs. IMRT treatment planning of prostate cancer.
    Guckenberger M; Meyer J; Baier K; Vordermark D; Flentje M
    Radiat Oncol; 2006 Sep; 1():34. PubMed ID: 16956403
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A comparison of conformal and intensity modulated treatment planning techniques for early prostate cancer.
    Vaarkamp J; Malde R; Dixit S; Hamilton CS
    J Med Imaging Radiat Oncol; 2009 Jun; 53(3):310-7. PubMed ID: 19624299
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.