275 related articles for article (PubMed ID: 26152468)
21. Artificial ventilation during transport: A randomized crossover study of manual resuscitators with comparison to mechanical ventilators in a simulation model.
Lucy MJ; Gamble JJ; Peeling A; Lam JTH; Balbuena L
Paediatr Anaesth; 2018 Sep; 28(9):788-794. PubMed ID: 30175433
[TBL] [Abstract][Full Text] [Related]
22. Device capable of reducing gastric inflation during artificial ventilation in a manikin model.
Mutzbauer T; Tabacek G
J Emerg Med; 2010 May; 38(4):428-33. PubMed ID: 18486408
[TBL] [Abstract][Full Text] [Related]
23. Decreasing peak flow rate with a new bag-valve-mask device: effects on respiratory mechanics, and gas distribution in a bench model of an unprotected airway.
Wagner-Berger HG; Wenzel V; Stallinger A; Voelckel WG; Rheinberger K; Stadlbauer KH; Augenstein S; Dörges V; Lindner KH; Hörmann C
Resuscitation; 2003 May; 57(2):193-9. PubMed ID: 12745188
[TBL] [Abstract][Full Text] [Related]
24. Comparison of devices for newborn ventilation in the delivery room.
Szyld E; Aguilar A; Musante GA; Vain N; Prudent L; Fabres J; Carlo WA;
J Pediatr; 2014 Aug; 165(2):234-239.e3. PubMed ID: 24690329
[TBL] [Abstract][Full Text] [Related]
25. Preferences and practices: use of neonatal resuscitation devices in low-resource settings.
Coffey PS; Kelly K; Tsu V
J Trop Pediatr; 2007 Dec; 53(6):415-9. PubMed ID: 17984126
[TBL] [Abstract][Full Text] [Related]
26. Evaluation of the Augmented Infant Resuscitator: A Monitoring Device for Neonatal Bag-Valve-Mask Resuscitation.
Bennett DJ; Itagaki T; Chenelle CT; Bittner EA; Kacmarek RM
Anesth Analg; 2018 Mar; 126(3):947-955. PubMed ID: 28863023
[TBL] [Abstract][Full Text] [Related]
27. Sustained inflations: comparing three neonatal resuscitation devices.
Klingenberg C; Dawson JA; Gerber A; Kamlin CO; Davis PG; Morley CJ
Neonatology; 2011; 100(1):78-84. PubMed ID: 21273792
[TBL] [Abstract][Full Text] [Related]
28. How can a single rescuer adequately deliver tidal volume with a manual resuscitator? An improved device for delivering regular tidal volume.
Cho YC; Cho SW; Chung SP; Yu K; Kwon OY; Kim SW
Emerg Med J; 2011 Jan; 28(1):40-3. PubMed ID: 21131393
[TBL] [Abstract][Full Text] [Related]
29. Comparison of different airway management strategies to ventilate apneic, nonpreoxygenated patients.
Dörges V; Wenzel V; Knacke P; Gerlach K
Crit Care Med; 2003 Mar; 31(3):800-4. PubMed ID: 12626987
[TBL] [Abstract][Full Text] [Related]
30. Effects of decreasing inspiratory flow rate during simulated basic life support ventilation of a cardiac arrest patient on lung and stomach tidal volumes.
Stallinger A; Wenzel V; Wagner-Berger H; Schäfer A; Voelckel WG; Augenstein S; Dörges V; Idris AH; Lindner KH; Hörmann C
Resuscitation; 2002 Aug; 54(2):167-73. PubMed ID: 12161296
[TBL] [Abstract][Full Text] [Related]
31. Evaluation of a novel paediatric self-inflating bag to improve accuracy of tidal volumes delivered during simulated advanced paediatric resuscitation.
Park SO; Lee KR; Baek KJ; Shim HW; Hong DY
Resuscitation; 2012 Jan; 83(1):101-6. PubMed ID: 21864479
[TBL] [Abstract][Full Text] [Related]
32. Mask leak increases and minute ventilation decreases when chest compressions are added to bag ventilation in a neonatal manikin model.
Tracy MB; Shah D; Hinder M; Klimek J; Marceau J; Wright A
Acta Paediatr; 2014 May; 103(5):e182-7. PubMed ID: 24460811
[TBL] [Abstract][Full Text] [Related]
33. Comparison of manually triggered ventilation and bag-valve-mask ventilation during cardiopulmonary resuscitation in a manikin model.
Bergrath S; Rossaint R; Biermann H; Skorning M; Beckers SK; Rörtgen D; Brokmann JCh; Flege C; Fitzner C; Czaplik M
Resuscitation; 2012 Apr; 83(4):488-93. PubMed ID: 21958929
[TBL] [Abstract][Full Text] [Related]
34. Mask leak in one-person mask ventilation compared to two-person in newborn infant manikin study.
Tracy MB; Klimek J; Coughtrey H; Shingde V; Ponnampalam G; Hinder M; Maheshwari R; Tracy SK
Arch Dis Child Fetal Neonatal Ed; 2011 May; 96(3):F195-200. PubMed ID: 21071683
[TBL] [Abstract][Full Text] [Related]
35. Delivery of Positive End-Expiratory Pressure Using Self-Inflating Bags during Newborn Resuscitation Is Possible Despite Mask Leak.
Gomo ØH; Eilevstjønn J; Holte K; Yeconia A; Kidanto H; Ersdal HL
Neonatology; 2020; 117(3):341-348. PubMed ID: 32610333
[TBL] [Abstract][Full Text] [Related]
36. Smaller tidal volumes during cardiopulmonary resuscitation: comparison of adult and paediatric self-inflatable bags with three different ventilatory devices.
Doerges V; Sauer C; Ocker H; Wenzel V; Schmucker P
Resuscitation; 1999 Dec; 43(1):31-7. PubMed ID: 10636315
[TBL] [Abstract][Full Text] [Related]
37. A randomised crossover comparison of mouth-to-face-shield ventilation and mouth-to-pocket-mask ventilation by surf lifeguards in a manikin.
Adelborg K; Bjørnshave K; Mortensen MB; Espeseth E; Wolff A; Løfgren B
Anaesthesia; 2014 Jul; 69(7):712-6. PubMed ID: 24773395
[TBL] [Abstract][Full Text] [Related]
38. Neonatal resuscitation 3: manometer use in a model of face mask ventilation.
O'Donnell CP; Davis PG; Lau R; Dargaville PA; Doyle LW; Morley CJ
Arch Dis Child Fetal Neonatal Ed; 2005 Sep; 90(5):F397-400. PubMed ID: 15871988
[TBL] [Abstract][Full Text] [Related]
39. Delivery of titrated oxygen via a self-inflating resuscitation bag.
Young P; Pilcher J; Patel M; Cameron L; Braithwaite I; Weatherall M; Beasley R
Resuscitation; 2013 Mar; 84(3):391-4. PubMed ID: 22955052
[TBL] [Abstract][Full Text] [Related]
40. Positive pressure ventilation at neonatal resuscitation: review of equipment and international survey of practice.
O'Donnell CP; Davis PG; Morley CJ
Acta Paediatr; 2004 May; 93(5):583-8. PubMed ID: 15174776
[TBL] [Abstract][Full Text] [Related]