BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

284 related articles for article (PubMed ID: 26152900)

  • 1. Improved black-blood imaging using DANTE-SPACE for simultaneous carotid and intracranial vessel wall evaluation.
    Xie Y; Yang Q; Xie G; Pang J; Fan Z; Li D
    Magn Reson Med; 2016 Jun; 75(6):2286-94. PubMed ID: 26152900
    [TBL] [Abstract][Full Text] [Related]  

  • 2. High resolution simultaneous imaging of intracranial and extracranial arterial wall with improved cerebrospinal fluid suppression.
    Zhang L; Zhang N; Wu J; Liu X; Chung YC
    Magn Reson Imaging; 2017 Dec; 44():65-71. PubMed ID: 28807750
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Black-blood multicontrast imaging of carotid arteries with DANTE-prepared 2D and 3D MR imaging.
    Li L; Chai JT; Biasiolli L; Robson MD; Choudhury RP; Handa AI; Near J; Jezzard P
    Radiology; 2014 Nov; 273(2):560-9. PubMed ID: 24918958
    [TBL] [Abstract][Full Text] [Related]  

  • 4. T2-Weighted intracranial vessel wall imaging at 7 Tesla using a DANTE-prepared variable flip angle turbo spin echo readout (DANTE-SPACE).
    Viessmann O; Li L; Benjamin P; Jezzard P
    Magn Reson Med; 2017 Feb; 77(2):655-663. PubMed ID: 26890988
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Variable impact of CSF flow suppression on quantitative 3.0T intracranial vessel wall measurements.
    Cogswell PM; Siero JCW; Lants SK; Waddle S; Davis LT; Gilbert G; Hendrikse J; Donahue MJ
    J Magn Reson Imaging; 2018 Oct; 48(4):1120-1128. PubMed ID: 29603829
    [TBL] [Abstract][Full Text] [Related]  

  • 6. High-resolution magnetic resonance imaging of intracranial vessel walls: Comparison of 3D T1-weighted turbo spin echo with or without DANTE or iMSDE.
    Cho SJ; Jung SC; Suh CH; Lee JB; Kim D
    PLoS One; 2019; 14(8):e0220603. PubMed ID: 31386679
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Carotid arterial wall MRI of apolipoprotein e-deficient mouse at 7 T using DANTE-prepared variable-flip-angle rapid acquisition with relaxation enhancement.
    Yang Y; Li Z; Liu Q; Guo Y; Mei Y; Lyu J; Zhao M; Feng Y; Xie G
    Magn Reson Imaging; 2022 Feb; 86():1-9. PubMed ID: 34688846
    [TBL] [Abstract][Full Text] [Related]  

  • 8. DANTE-prepared three-dimensional FLASH: A fast isotropic-resolution MR approach to morphological evaluation of the peripheral arterial wall at 3 Tesla.
    Xie G; Zhang N; Xie Y; Nguyen C; Deng Z; Bi X; Fan Z; Liu X; Li D; Fan Z
    J Magn Reson Imaging; 2016 Feb; 43(2):343-51. PubMed ID: 26139414
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The development and optimisation of 3D black-blood R
    Yuan J; Graves MJ; Patterson AJ; Priest AN; Ruetten PPR; Usman A; Gillard JH
    Magn Reson Imaging; 2017 Dec; 44():104-110. PubMed ID: 28867671
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Double delay alternating with nutation for tailored excitation facilitates banding-free isotropic high-resolution intracranial vessel wall imaging.
    Coolen BF; Schoormans J; Gilbert G; Kooreman ES; de Winter N; Viessmann O; Zwanenburg JJM; Majoie CBLM; Strijkers GJ; Nederveen AJ; Siero JCW
    NMR Biomed; 2021 Sep; 34(9):e4567. PubMed ID: 34076305
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Whole-brain intracranial vessel wall imaging at 3 Tesla using cerebrospinal fluid-attenuated T1-weighted 3D turbo spin echo.
    Fan Z; Yang Q; Deng Z; Li Y; Bi X; Song S; Li D
    Magn Reson Med; 2017 Mar; 77(3):1142-1150. PubMed ID: 26923198
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Joint blood and cerebrospinal fluid suppression for intracranial vessel wall MRI.
    Wang J; Helle M; Zhou Z; Börnert P; Hatsukami TS; Yuan C
    Magn Reson Med; 2016 Feb; 75(2):831-8. PubMed ID: 25772551
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Intravascular signal suppression and microvascular signal mapping using delays alternating with nutation for tailored excitation (DANTE) pulse for arterial spin labeling perfusion imaging.
    Fujiwara Y; Kimura H; Ishida S; Kanamoto M; Takei N; Matsuda T; Kosaka N; Adachi T
    MAGMA; 2020 Jun; 33(3):367-376. PubMed ID: 31625029
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Hyperecho PROPELLER-MRI: Application to rapid high-resolution motion-insensitive T
    Yoneyama M; Nakamura M; Obara M; Okuaki T; Sashi R; Sawano S; Tatsuno S; Van Cauteren M
    J Magn Reson Imaging; 2017 Feb; 45(2):515-524. PubMed ID: 27392068
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Image-Quality Assessment of 3D Intracranial Vessel Wall MRI Using DANTE or DANTE-CAIPI for Blood Suppression and Imaging Acceleration.
    Sannananja B; Zhu C; Colip CG; Somasundaram A; Ibrahim M; Khrisat T; Mossa-Basha M
    AJNR Am J Neuroradiol; 2022 Jun; 43(6):837-843. PubMed ID: 35618420
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Isotropic 3D black blood MRI of abdominal aortic aneurysm wall and intraluminal thrombus.
    Zhu C; Haraldsson H; Faraji F; Owens C; Gasper W; Ahn S; Liu J; Laub G; Hope MD; Saloner D
    Magn Reson Imaging; 2016 Jan; 34(1):18-25. PubMed ID: 26471514
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Improved cerebrospinal fluid suppression for intracranial vessel wall MRI.
    Yang H; Zhang X; Qin Q; Liu L; Wasserman BA; Qiao Y
    J Magn Reson Imaging; 2016 Sep; 44(3):665-72. PubMed ID: 26950926
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Carotid artery wall imaging using 7.0T magnetic resonance imaging with threedimensional DANTE-prepared FLASH in ApoE
    Yang Y; Li Z; Liu Q; Xie G; Feng Y
    Nan Fang Yi Ke Da Xue Xue Bao; 2021 Feb; 41(2):216-222. PubMed ID: 33624594
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Whole-brain vessel wall MRI: A parameter tune-up solution to improve the scan efficiency of three-dimensional variable flip-angle turbo spin-echo.
    Yang Q; Deng Z; Bi X; Song SS; Schlick KH; Gonzalez NR; Li D; Fan Z
    J Magn Reson Imaging; 2017 Sep; 46(3):751-757. PubMed ID: 28106936
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Accelerated multi-contrast high isotropic resolution 3D intracranial vessel wall MRI using a tailored k-space undersampling and partially parallel reconstruction strategy.
    Balu N; Zhou Z; Hippe DS; Hatsukami T; Mossa-Basha M; Yuan C
    MAGMA; 2019 Jun; 32(3):343-357. PubMed ID: 30607664
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 15.