These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
347 related articles for article (PubMed ID: 26154703)
1. Experimental study of the characteristics of a novel mesh suture. Dumanian GA; Tulaimat A; Dumanian ZP Br J Surg; 2015 Sep; 102(10):1285-92. PubMed ID: 26154703 [TBL] [Abstract][Full Text] [Related]
2. In vivo evaluation of a novel mesh suture design for abdominal wall closure. Souza JM; Dumanian ZP; Gurjala AN; Dumanian GA Plast Reconstr Surg; 2015 Feb; 135(2):322e-330e. PubMed ID: 25626817 [TBL] [Abstract][Full Text] [Related]
3. Suturable mesh better resists early laparotomy failure in a cyclic ball-burst model. Scheiber CJ; Kurapaty SS; Goldman SM; Dearth CL; Liacouras PC; Souza JM Hernia; 2020 Jun; 24(3):559-565. PubMed ID: 32040788 [TBL] [Abstract][Full Text] [Related]
4. New suture materials for midline laparotomy closure: an experimental study. Bellón JM; Pérez-López P; Simón-Allue R; Sotomayor S; Pérez-Köhler B; Peña E; Pascual G; Calvo B BMC Surg; 2014 Sep; 14():70. PubMed ID: 25231161 [TBL] [Abstract][Full Text] [Related]
5. Modifying hernia mesh design to improve device mechanical performance and promote tension-free repair. Ibrahim MM; Poveromo LP; Glisson RR; Cornejo A; Farjat AE; Gall K; Levinson H J Biomech; 2018 Apr; 71():43-51. PubMed ID: 29426630 [TBL] [Abstract][Full Text] [Related]
6. Midline abdominal wall closure: a new prophylactic mesh concept. Bellón JM; López-Hervás P; Rodríguez M; García-Honduvilla N; Pascual G; Buján J J Am Coll Surg; 2006 Oct; 203(4):490-7. PubMed ID: 17000392 [TBL] [Abstract][Full Text] [Related]
7. Torsion of monofilament and polyfilament sutures under tension decreases suture strength and increases risk of suture fracture. Hennessey DB; Carey E; Simms CK; Hanly A; Winter DC J Mech Behav Biomed Mater; 2012 Aug; 12():168-73. PubMed ID: 22762905 [TBL] [Abstract][Full Text] [Related]
8. Tensile strength of mesh fixation methods in laparoscopic incisional hernia repair. van't Riet M; de Vos van Steenwijk PJ; Kleinrensink GJ; Steyerberg EW; Bonjer HJ Surg Endosc; 2002 Dec; 16(12):1713-6. PubMed ID: 12098028 [TBL] [Abstract][Full Text] [Related]
9. Comparison of strength of sacrocolpopexy mesh attachment using barbed and nonbarbed sutures. Pilkinton ML; Levine GC; Bennett L; Winkler HA; Shalom DF; Finamore PS Int Urogynecol J; 2018 Jan; 29(1):153-159. PubMed ID: 28980021 [TBL] [Abstract][Full Text] [Related]
10. Tissue strength of structures involved in musculo-aponeurotic layer sutures in laparotomy incisions. Tera H; Aberg C Acta Chir Scand; 1976; 142(5):349-55. PubMed ID: 790883 [TBL] [Abstract][Full Text] [Related]
11. Influence of laparotomy closure technique on collagen synthesis in the incisional region. Höer JJ; Junge K; Schachtrupp A; Klinge U; Schumpelick V Hernia; 2002 Sep; 6(3):93-8. PubMed ID: 12209295 [TBL] [Abstract][Full Text] [Related]
12. [Polypropylene and polydioxanone show similar biomechanical efficacy in midline closure]. Bellón JM; Rodríguez M; Serrano N; García-Honduvilla N; Gómez V; Buján J Cir Esp; 2005 Dec; 78(6):377-81. PubMed ID: 16420865 [TBL] [Abstract][Full Text] [Related]
13. Fascial Closure: New Surgery Paradigms. Dumanian GA; Moradian S Adv Surg; 2020 Sep; 54():215-229. PubMed ID: 32713432 [No Abstract] [Full Text] [Related]
14. Experimental study of the characteristics of a novel mesh suture (Br J Surg 2015; 102: 1285-1292). Petter-Puchner A Br J Surg; 2015 Sep; 102(10):1292-3. PubMed ID: 26267605 [No Abstract] [Full Text] [Related]
15. Influence of suture technique on laparotomy wound healing: an experimental study in the rat. Höer J; Klinge U; Schachtrupp A; Töns C; Schumpelick V Langenbecks Arch Surg; 2001 Apr; 386(3):218-23. PubMed ID: 11382325 [TBL] [Abstract][Full Text] [Related]
16. Comparison of stainless steel fascial staples and polypropylene suture material for closure of the linea alba in dogs. Kirpensteijn J; Fingland RB; Boyer JE; Kennedy GA; Klemm RD; Debowes RM Vet Surg; 1993; 22(6):464-72. PubMed ID: 8116202 [TBL] [Abstract][Full Text] [Related]
17. Mesh incisional herniorrhaphy increases abdominal wall elastic properties: a mechanism for decreased hernia recurrences in comparison with suture repair. DuBay DA; Wang X; Adamson B; Kuzon WM; Dennis RG; Franz MG Surgery; 2006 Jul; 140(1):14-24. PubMed ID: 16857438 [TBL] [Abstract][Full Text] [Related]
18. Mechanical characterization of endoscopic surgical staples during an experimental hernia repair. Charara J; Dion YM; Guidoin R Clin Mater; 1994; 16(2):81-9. PubMed ID: 10147327 [TBL] [Abstract][Full Text] [Related]
19. Tensile strength and failure load of sutures for robotic surgery. Abiri A; Paydar O; Tao A; LaRocca M; Liu K; Genovese B; Candler R; Grundfest WS; Dutson EP Surg Endosc; 2017 Aug; 31(8):3258-3270. PubMed ID: 27928670 [TBL] [Abstract][Full Text] [Related]
20. An objective comparison of holding, slippage, and pull-out tensions for eight suspension sutures in the malar fat pads of fresh-frozen human cadavers. Sasaki GH; Komorowska-Timek ED; Bennett DC; Gabriel A Aesthet Surg J; 2008; 28(4):387-96. PubMed ID: 19083551 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]