These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

274 related articles for article (PubMed ID: 26155551)

  • 1. Comparative Analysis of Canal Centering Ability of Different Single File Systems Using Cone Beam Computed Tomography- An In-Vitro Study.
    Agarwal RS; Agarwal J; Jain P; Chandra A
    J Clin Diagn Res; 2015 May; 9(5):ZC06-10. PubMed ID: 26155551
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparative study of different novel nickel-titanium rotary systems for root canal preparation in severely curved root canals.
    Capar ID; Ertas H; Ok E; Arslan H; Ertas ET
    J Endod; 2014 Jun; 40(6):852-6. PubMed ID: 24862716
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparative evaluation of shaping ability of different rotary NiTi instruments in curved canals using CBCT.
    Arora A; Taneja S; Kumar M
    J Conserv Dent; 2014 Jan; 17(1):35-9. PubMed ID: 24554858
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of canal transportation and centering ability of rotary protaper, one shape system and wave one system using cone beam computed tomography: An in vitro study.
    Tambe VH; Nagmode PS; Abraham S; Patait M; Lahoti PV; Jaju N
    J Conserv Dent; 2014 Nov; 17(6):561-5. PubMed ID: 25506145
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of canal transportation and centering ability of Xp Shaper, WaveOne and Oneshape: a cone beam computed tomography study of curved root canals.
    Hassan R; Roshdy N; Issa N
    Acta Odontol Latinoam; 2018 Jun; 31(1):67-74. PubMed ID: 30056469
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparative evaluation of canal transportation and centering ability of rotary and reciprocating file systems using cone-beam computed tomography: An
    Singh T; Kumari M; Kochhar R
    J Conserv Dent; 2023; 26(3):332-337. PubMed ID: 37398849
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparative Evaluation of Root Canal Transportation and Centering Ability in Curved Mesiobuccal Canals of Mandibular First Molars after Instrumentation with Different File Systems-An
    Langaliya A; Kothari A; Buch A; Dave R; Shah J; Shah N
    J Pharm Bioallied Sci; 2023 Jul; 15(Suppl 2):S1211-S1214. PubMed ID: 37694024
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Computed tomography evaluation of rotary systems on the root canal transportation and centering ability.
    Pagliosa A; Sousa-Neto MD; Versiani MA; Raucci-Neto W; Silva-Sousa YT; Alfredo E
    Braz Oral Res; 2015; 29():. PubMed ID: 25715038
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A micro-computed tomography-based comparison of the canal transportation and centering ability of ProTaper Universal rotary and WaveOne reciprocating files.
    McRay B; Cox TC; Cohenca N; Johnson JD; Paranjpe A
    Quintessence Int; 2014 Feb; 45(2):101-8. PubMed ID: 24389561
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparative Evaluation of Canal-shaping Abilities of RaceEvo, R-Motion, Reciproc Blue, and ProTaper Gold NiTi Rotary File Systems: A CBCT Study.
    Mustafa M
    J Contemp Dent Pract; 2021 Dec; 22(12):1406-1412. PubMed ID: 35656678
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Cone-beam computed tomographic analysis of apical transportation and centering ratio of ProTaper and XP-endo Shaper NiTi rotary systems in curved canals: an in vitro study.
    Karkehabadi H; Siahvashi Z; Shokri A; Haji Hasani N
    BMC Oral Health; 2021 May; 21(1):277. PubMed ID: 34034735
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Cone-beam Computed Tomographic Assessment of Canal Centering Ability and Transportation after Preparation with Twisted File and Bio RaCe Instrumentation.
    Honardar K; Assadian H; Shahab S; Jafari Z; Kazemi A; Nazarimoghaddam K; Kharrazifard MJ; Labbaf H
    J Dent (Tehran); 2014 Jul; 11(4):440-6. PubMed ID: 25584056
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of Single File Systems Reciproc, Oneshape, and WaveOne using Cone Beam Computed Tomography -An In Vitro Study.
    Dhingra A; Ruhal N; Miglani A
    J Clin Diagn Res; 2015 Apr; 9(4):ZC30-4. PubMed ID: 26023639
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Influence of motion pattern on apical transportation and centering ability of WaveOne single-file technique in curved root canals.
    Naseri M; Paymanpour P; Kangarloo A; Haddadpur S; Dianat O; Ketabi MA
    Dent Res J (Isfahan); 2016; 13(1):13-7. PubMed ID: 26962310
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparative Evaluation of Root Canal Centering Ability of ProTaper, Mtwo, WaveOne, and Reciproc Using Cone-beam Computed Tomography:
    Remya M; Singh P; Varughese A; Joseph A; Chandran P; Subramanian D; Kumar SV
    J Contemp Dent Pract; 2022 Sep; 23(6):589-592. PubMed ID: 36259296
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of Canal Transportation, Centering Ratio by Cone-beam Computed Tomography after Preparation with Different File Systems.
    Uzunoglu E; Turker SA
    J Contemp Dent Pract; 2015 May; 16(5):360-5. PubMed ID: 26162254
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparative Assessment of Canal Transportation and Centering Ability of Reciproc and One Shape File Systems Using CBCT-An In Vitro Study.
    Mittal A; Dadu S; Singh NS; Singh S; Gupta B; Abraham A; Yendrembam B; Kumari S
    J Clin Diagn Res; 2017 Apr; 11(4):ZC31-ZC34. PubMed ID: 28571257
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of canal transportation and centering ability of Twisted Files, HyFlex controlled memory, and Wave One using computed tomography scan: An
    Kishore A; Gurtu A; Bansal R; Singhal A; Mohan S; Mehrotra A
    J Conserv Dent; 2017; 20(3):161-165. PubMed ID: 29279618
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Canal transportation and centering ability of protaper and self-adjusting file system in long oval canals: An
    Shah DY; Wadekar SI; Dadpe AM; Jadhav GR; Choudhary LJ; Kalra DD
    J Conserv Dent; 2017; 20(2):105-109. PubMed ID: 28855757
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Shaping Ability of 5(th) Generation Ni-Ti Rotary Systems for Root Canal Preparation in Curved Root Canals using CBCT: An In Vitro Study.
    Deepak J; Ashish M; Patil N; Kadam N; Yadav V; Jagdale H
    J Int Oral Health; 2015; 7(Suppl 1):57-61. PubMed ID: 26225107
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 14.