BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

145 related articles for article (PubMed ID: 26158057)

  • 1. Characterization of scatter magnitude and distribution in dedicated breast computed tomography with bowtie filters.
    Kontson K; Jennings RJ
    J Med Imaging (Bellingham); 2014 Oct; 1(3):033505. PubMed ID: 26158057
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Bowtie filters for dedicated breast CT: theory and computational implementation.
    Kontson K; Jennings RJ
    Med Phys; 2015 Mar; 42(3):1453-62. PubMed ID: 25735298
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Bowtie filters for dedicated breast CT: Analysis of bowtie filter material selection.
    Kontson K; Jennings RJ
    Med Phys; 2015 Sep; 42(9):5270-7. PubMed ID: 26328976
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The effects of compensator and imaging geometry on the distribution of x-ray scatter in CBCT.
    Bootsma GJ; Verhaegen F; Jaffray DA
    Med Phys; 2011 Feb; 38(2):897-914. PubMed ID: 21452727
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Impact of bowtie filter and detector collimation on multislice CT scatter profiles: A simulation study.
    Liu R; Zhang S; Zhao T; O'Sullivan JA; Williamson JF; Webb T; Porras-Chaverri M; Whiting B
    Med Phys; 2021 Feb; 48(2):852-870. PubMed ID: 33296513
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Evaluation of detector readout gain mode and bowtie filters for cone-beam CT imaging of the head.
    Xu J; Sisniega A; Zbijewski W; Dang H; Stayman JW; Wang X; Foos DH; Aygun N; Koliatsos VE; Siewerdsen JH
    Phys Med Biol; 2016 Aug; 61(16):5973-92. PubMed ID: 27435162
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Simulated scatter performance of an inverse-geometry dedicated breast CT system.
    Bhagtani R; Schmidt TG
    Med Phys; 2009 Mar; 36(3):788-96. PubMed ID: 19378739
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of x-ray scatter properties in a dedicated cone-beam breast CT scanner.
    Kwan AL; Boone JM; Shah N
    Med Phys; 2005 Sep; 32(9):2967-75. PubMed ID: 16266111
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Correction of Bowtie filter induced scatter signals based on air scan data and object scan data.
    Zhang G; Wang Y; Chen W; Li T; Tian Y
    Biomed Phys Eng Express; 2022 Jun; 8(4):. PubMed ID: 35276688
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Bowtie filtration for dedicated cone beam CT of the head and neck: a simulation study.
    Zhang G; Marshall N; Jacobs R; Liu Q; Bosmans H
    Br J Radiol; 2013 Aug; 86(1028):20130002. PubMed ID: 23728948
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Mathematical modelling of scanner-specific bowtie filters for Monte Carlo CT dosimetry.
    Kramer R; Cassola VF; Andrade ME; de Araújo MW; Brenner DJ; Khoury HJ
    Phys Med Biol; 2017 Feb; 62(3):781-809. PubMed ID: 28072578
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Monte Carlo evaluation of scatter mitigation strategies in cone-beam CT.
    Lazos D; Williamson JF
    Med Phys; 2010 Oct; 37(10):5456-70. PubMed ID: 21089782
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Deep learning for x-ray scatter correction in dedicated breast CT.
    Pautasso JJ; Caballo M; Mikerov M; Boone JM; Michielsen K; Sechopoulos I
    Med Phys; 2023 Apr; 50(4):2022-2036. PubMed ID: 36565012
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effect of shaped filter design on dose and image quality in breast CT.
    Lück F; Kolditz D; Hupfer M; Kalender WA
    Phys Med Biol; 2013 Jun; 58(12):4205-23. PubMed ID: 23715466
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Hybrid deterministic-stochastic modeling of x-ray beam bowtie filter scatter on a CT system.
    Liu X; Hsieh J
    J Xray Sci Technol; 2015; 23(5):593-600. PubMed ID: 26409426
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Decoupling of bowtie and object effects for beam hardening and scatter artefact reduction in iterative cone-beam CT.
    Cai M; Byrne M; Archibald-Heeren B; Metcalfe P; Rosenfeld A; Wang Y
    Phys Eng Sci Med; 2020 Dec; 43(4):1161-1170. PubMed ID: 32813233
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A novel hardware duo of beam modulation and shielding to reduce scatter acquisition and dose in cone-beam breast CT.
    Ghazi P; Youssefian S; Ghazi T
    Med Phys; 2022 Jan; 49(1):169-185. PubMed ID: 34825715
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Acuros CTS: A fast, linear Boltzmann transport equation solver for computed tomography scatter - Part I: Core algorithms and validation.
    Maslowski A; Wang A; Sun M; Wareing T; Davis I; Star-Lack J
    Med Phys; 2018 May; 45(5):1899-1913. PubMed ID: 29509970
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Acuros CTS: A fast, linear Boltzmann transport equation solver for computed tomography scatter - Part II: System modeling, scatter correction, and optimization.
    Wang A; Maslowski A; Messmer P; Lehmann M; Strzelecki A; Yu E; Paysan P; Brehm M; Munro P; Star-Lack J; Seghers D
    Med Phys; 2018 May; 45(5):1914-1925. PubMed ID: 29509973
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Fluid-filled dynamic bowtie filter: Description and comparison with other modulators.
    Shunhavanich P; Hsieh SS; Pelc NJ
    Med Phys; 2019 Jan; 46(1):127-139. PubMed ID: 30383310
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.