140 related articles for article (PubMed ID: 26158077)
1. On image quality metrics and the usefulness of grids in digital mammography.
Chen H; Danielsson M; Xu C; Cederström B
J Med Imaging (Bellingham); 2015 Jan; 2(1):013501. PubMed ID: 26158077
[TBL] [Abstract][Full Text] [Related]
2. Effects on image quality of a 2D antiscatter grid in x-ray digital breast tomosynthesis: Initial experience using the dual modality (x-ray and molecular) breast tomosynthesis scanner.
Patel T; Peppard H; Williams MB
Med Phys; 2016 Apr; 43(4):1720. PubMed ID: 27036570
[TBL] [Abstract][Full Text] [Related]
3. The effect of scatter and glare on image quality in contrast-enhanced breast imaging using an a-Si/CsI(TI) full-field flat panel detector.
Carton AK; Acciavatti R; Kuo J; Maidment AD
Med Phys; 2009 Mar; 36(3):920-8. PubMed ID: 19378752
[TBL] [Abstract][Full Text] [Related]
4. Grid removal and impact on population dose in full-field digital mammography.
Gennaro G; Katz L; Souchay H; Klausz R; Alberelli C; di Maggio C
Med Phys; 2007 Feb; 34(2):547-55. PubMed ID: 17388172
[TBL] [Abstract][Full Text] [Related]
5. Effective detective quantum efficiency for two mammography systems: measurement and comparison against established metrics.
Salvagnini E; Bosmans H; Struelens L; Marshall NW
Med Phys; 2013 Oct; 40(10):101916. PubMed ID: 24089918
[TBL] [Abstract][Full Text] [Related]
6. The impact of X-ray scatter correction software on abdomen radiography in terms of image quality and radiation dose.
Sayed M; Knapp KM; Fulford J; Heales C; Alqahtani SJ
Radiography (Lond); 2024 Jul; 30(4):1125-1135. PubMed ID: 38797045
[TBL] [Abstract][Full Text] [Related]
7. Quantification of scattered radiation in projection mammography: four practical methods compared.
Salvagnini E; Bosmans H; Struelens L; Marshall NW
Med Phys; 2012 Jun; 39(6):3167-80. PubMed ID: 22755701
[TBL] [Abstract][Full Text] [Related]
8. [Dose reduction through gridless technique in digital full-field mammography].
Diekmann F; Diekmann S; Berzeg S; Bick U; Fischer T; Hamm B
Rofo; 2003 Jun; 175(6):769-74. PubMed ID: 12811688
[TBL] [Abstract][Full Text] [Related]
9. Towards standardization of x-ray beam filters in digital mammography and digital breast tomosynthesis: Monte Carlo simulations and analytical modelling.
Shrestha S; Vedantham S; Karellas A
Phys Med Biol; 2017 Mar; 62(5):1969-1993. PubMed ID: 28075335
[TBL] [Abstract][Full Text] [Related]
10. Effect of scatter and an antiscatter grid on the performance of a slot-scanning digital mammography system.
Shen SZ; Bloomquist AK; Mawdsley GE; Yaffe MJ; Elbakri I
Med Phys; 2006 Apr; 33(4):1108-15. PubMed ID: 16696488
[TBL] [Abstract][Full Text] [Related]
11. Characterization of scatter in digital mammography from physical measurements.
Leon SM; Brateman LF; Wagner LK
Med Phys; 2014 Jun; 41(6):061901. PubMed ID: 24877812
[TBL] [Abstract][Full Text] [Related]
12. A comprehensive model for x-ray projection imaging system efficiency and image quality characterization in the presence of scattered radiation.
Monnin P; Verdun FR; Bosmans H; Pérez SR; Marshall NW
Phys Med Biol; 2017 Jun; 62(14):5691-5722. PubMed ID: 28557801
[TBL] [Abstract][Full Text] [Related]
13. The effect of the antiscatter grid on full-field digital mammography phantom images.
Chakraborty DP
J Digit Imaging; 1999 Feb; 12(1):12-22. PubMed ID: 10036663
[TBL] [Abstract][Full Text] [Related]
14. Improved image quality of cone beam CT scans for radiotherapy image guidance using fiber-interspaced antiscatter grid.
Stankovic U; van Herk M; Ploeger LS; Sonke JJ
Med Phys; 2014 Jun; 41(6):061910. PubMed ID: 24877821
[TBL] [Abstract][Full Text] [Related]
15. A semi-empirical model for scatter field reduction in digital mammography.
Marimón E; Marsden PA; Nait-Charif H; Díaz O
Phys Med Biol; 2021 Feb; 66(4):045001. PubMed ID: 33296884
[TBL] [Abstract][Full Text] [Related]
16. Evaluation of scatter-to-primary ratio, grid performance and normalized average glandular dose in mammography by Monte Carlo simulation including interference and energy broadening effects.
Cunha DM; Tomal A; Poletti ME
Phys Med Biol; 2010 Aug; 55(15):4335-59. PubMed ID: 20647608
[TBL] [Abstract][Full Text] [Related]
17. Experimental evaluation of fiber-interspaced antiscatter grids for large patient imaging with digital x-ray systems.
Fetterly KA; Schueler BA
Phys Med Biol; 2007 Aug; 52(16):4863-80. PubMed ID: 17671340
[TBL] [Abstract][Full Text] [Related]
18. Optimal combination of anti-scatter grids and software correction for CBCT imaging.
Stankovic U; Ploeger LS; van Herk M; Sonke JJ
Med Phys; 2017 Sep; 44(9):4437-4451. PubMed ID: 28556204
[TBL] [Abstract][Full Text] [Related]
19. The value of scatter removal by a grid in full field digital mammography.
Veldkamp WJ; Thijssen MA; Karssemeijer N
Med Phys; 2003 Jul; 30(7):1712-8. PubMed ID: 12906188
[TBL] [Abstract][Full Text] [Related]
20. Characterization of scatter in digital mammography from use of Monte Carlo simulations and comparison to physical measurements.
Leon SM; Brateman LF; Wagner LK
Med Phys; 2014 Nov; 41(11):111914. PubMed ID: 25370647
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]