These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
98 related articles for article (PubMed ID: 26159799)
1. Flip-angle profile of slice-selective excitation and the measurement of the MR longitudinal relaxation time with steady-state magnetization. Hsu JJ Phys Med Biol; 2015 Aug; 60(15):5785-801. PubMed ID: 26159799 [TBL] [Abstract][Full Text] [Related]
2. Spin-lattice relaxation and a fast T1-map acquisition method in MRI with transient-state magnetization. Hsu JJ; Lowe IJ J Magn Reson; 2004 Aug; 169(2):270-8. PubMed ID: 15261622 [TBL] [Abstract][Full Text] [Related]
3. Rapid assessment of longitudinal relaxation time in materials and tissues with extremely fast signal decay using UTE sequences and the variable flip angle method. Springer F; Steidle G; Martirosian P; Syha R; Claussen CD; Schick F Invest Radiol; 2011 Oct; 46(10):610-7. PubMed ID: 21577126 [TBL] [Abstract][Full Text] [Related]
4. Technical Note: The effect of 2D excitation profile on T1 measurement accuracy using the variable flip angle method with an average flip angle assumption. Svedin BT; Parker DL Med Phys; 2017 Nov; 44(11):5930-5937. PubMed ID: 28796308 [TBL] [Abstract][Full Text] [Related]
5. Flip-angle measurement by magnetization inversion: Calibration of magnetization nutation angle in hyperpolarized (3) He magnetic resonance imaging lung experiments. Rivoire J; Terekhov M; Meise FM; Gast K; Salhi Z; Schreiber LM Magn Reson Med; 2011 Feb; 65(2):399-408. PubMed ID: 20882641 [TBL] [Abstract][Full Text] [Related]
6. Effects of RF pulse profile and intra-voxel phase dispersion on MR fingerprinting with balanced SSFP readout. Chiu SC; Lin TM; Lin JM; Chung HW; Ko CW; Büchert M; Bock M Magn Reson Imaging; 2017 Sep; 41():80-86. PubMed ID: 28412455 [TBL] [Abstract][Full Text] [Related]
7. Generalized equation for describing the magnetization in spoiled gradient-echo imaging. Murase K Magn Reson Imaging; 2011 Jun; 29(5):723-30. PubMed ID: 21524871 [TBL] [Abstract][Full Text] [Related]
8. Effects of in-pulse transverse relaxation in 3D ultrashort echo time sequences: analytical derivation, comparison to numerical simulation and experimental application at 3T. Springer F; Steidle G; Martirosian P; Claussen CD; Schick F J Magn Reson; 2010 Sep; 206(1):88-96. PubMed ID: 20637661 [TBL] [Abstract][Full Text] [Related]
9. RF slice profile effects in magnetic resonance fingerprinting. Hong T; Han D; Kim MO; Kim DH Magn Reson Imaging; 2017 Sep; 41():73-79. PubMed ID: 28391061 [TBL] [Abstract][Full Text] [Related]
10. Accuracy, precision, and reproducibility of myocardial T1 mapping: A comparison of four T1 estimation algorithms for modified look-locker inversion recovery (MOLLI). Shao J; Liu D; Sung K; Nguyen KL; Hu P Magn Reson Med; 2017 Nov; 78(5):1746-1756. PubMed ID: 27917529 [TBL] [Abstract][Full Text] [Related]
11. Rapid 2D variable flip angle method for accurate and precise T Lena B; Bos C; Ferrer CJ; Moonen CTW; Viergever MA; Bartels LW NMR Biomed; 2021 Aug; 34(8):e4542. PubMed ID: 34031938 [TBL] [Abstract][Full Text] [Related]
12. Closed-form expressions for flip angle variation that maximize total signal in T1-weighted rapid gradient echo MRI. Drobnitzky M; Klose U Med Phys; 2017 Mar; 44(3):873-885. PubMed ID: 28061002 [TBL] [Abstract][Full Text] [Related]
13. Slice profile effects in 2D slice-selective MRI of hyperpolarized nuclei. Deppe MH; Teh K; Parra-Robles J; Lee KJ; Wild JM J Magn Reson; 2010 Feb; 202(2):180-9. PubMed ID: 19969495 [TBL] [Abstract][Full Text] [Related]
14. Consideration of slice profiles in inversion recovery Look-Locker relaxation parameter mapping. Tran-Gia J; Wech T; Hahn D; Bley TA; Köstler H Magn Reson Imaging; 2014 Oct; 32(8):1021-30. PubMed ID: 24960366 [TBL] [Abstract][Full Text] [Related]
15. On the use of steady-state signal equations for 2D TrueFISP imaging. Coolen BF; Heijman E; Nicolay K; Strijkers GJ Magn Reson Imaging; 2009 Jul; 27(6):815-22. PubMed ID: 19249169 [TBL] [Abstract][Full Text] [Related]