These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
208 related articles for article (PubMed ID: 26162554)
1. Improved sensitivity and specificity for resting state and task fMRI with multiband multi-echo EPI compared to multi-echo EPI at 7 T. Boyacioğlu R; Schulz J; Koopmans PJ; Barth M; Norris DG Neuroimage; 2015 Oct; 119():352-61. PubMed ID: 26162554 [TBL] [Abstract][Full Text] [Related]
2. Improved resting state functional connectivity sensitivity and reproducibility using a multiband multi-echo acquisition. Cohen AD; Yang B; Fernandez B; Banerjee S; Wang Y Neuroimage; 2021 Jan; 225():117461. PubMed ID: 33069864 [TBL] [Abstract][Full Text] [Related]
3. Using multiband multi-echo imaging to improve the robustness and repeatability of co-activation pattern analysis for dynamic functional connectivity. Cohen AD; Chang C; Wang Y Neuroimage; 2021 Nov; 243():118555. PubMed ID: 34492293 [TBL] [Abstract][Full Text] [Related]
4. A comparison of multiband and multiband multiecho gradient-echo EPI for task fMRI at 3 T. Fazal Z; Gomez DEP; Llera A; Marques JPRF; Beck T; Poser BA; Norris DG Hum Brain Mapp; 2023 Jan; 44(1):82-93. PubMed ID: 36196782 [TBL] [Abstract][Full Text] [Related]
5. Detecting Task Functional MRI Activation Using the Multiband Multiecho (MBME) Echo-Planar Imaging (EPI) Sequence. Cohen AD; Jagra AS; Yang B; Fernandez B; Banerjee S; Wang Y J Magn Reson Imaging; 2021 May; 53(5):1366-1374. PubMed ID: 33210793 [TBL] [Abstract][Full Text] [Related]
6. Whole brain, high resolution multiband spin-echo EPI fMRI at 7 T: a comparison with gradient-echo EPI using a color-word Stroop task. Boyacioğlu R; Schulz J; Müller NC; Koopmans PJ; Barth M; Norris DG Neuroimage; 2014 Aug; 97():142-50. PubMed ID: 24736172 [TBL] [Abstract][Full Text] [Related]
7. Investigating the benefits of multi-echo EPI for fMRI at 7 T. Poser BA; Norris DG Neuroimage; 2009 May; 45(4):1162-72. PubMed ID: 19349231 [TBL] [Abstract][Full Text] [Related]
8. Multiband multi-echo simultaneous ASL/BOLD for task-induced functional MRI. Cohen AD; Nencka AS; Wang Y PLoS One; 2018; 13(2):e0190427. PubMed ID: 29389985 [TBL] [Abstract][Full Text] [Related]
9. Multiband multi-echo imaging of simultaneous oxygenation and flow timeseries for resting state connectivity. Cohen AD; Nencka AS; Lebel RM; Wang Y PLoS One; 2017; 12(3):e0169253. PubMed ID: 28253268 [TBL] [Abstract][Full Text] [Related]
10. Evaluation of multi-echo ICA denoising for task based fMRI studies: Block designs, rapid event-related designs, and cardiac-gated fMRI. Gonzalez-Castillo J; Panwar P; Buchanan LC; Caballero-Gaudes C; Handwerker DA; Jangraw DC; Zachariou V; Inati S; Roopchansingh V; Derbyshire JA; Bandettini PA Neuroimage; 2016 Nov; 141():452-468. PubMed ID: 27475290 [TBL] [Abstract][Full Text] [Related]
11. Characterizing contrast origins and noise contribution in spin-echo EPI BOLD at 3 T. Ragot DM; Chen JJ Magn Reson Imaging; 2019 Apr; 57():328-336. PubMed ID: 30439514 [TBL] [Abstract][Full Text] [Related]
12. Rapid whole-brain resting-state fMRI at 3 T: Efficiency-optimized three-dimensional EPI versus repetition time-matched simultaneous-multi-slice EPI. Stirnberg R; Huijbers W; Brenner D; Poser BA; Breteler M; Stöcker T Neuroimage; 2017 Dec; 163():81-92. PubMed ID: 28923276 [TBL] [Abstract][Full Text] [Related]
13. BOLD sensitivity and SNR characteristics of parallel imaging-accelerated single-shot multi-echo EPI for fMRI. Bhavsar S; Zvyagintsev M; Mathiak K Neuroimage; 2014 Jan; 84():65-75. PubMed ID: 23954488 [TBL] [Abstract][Full Text] [Related]