These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

180 related articles for article (PubMed ID: 26165275)

  • 1. Multiplex MicroRNA Detection on a Power-free Microfluidic Chip with Laminar Flow-assisted Dendritic Amplification.
    Ishihara R; Hasegawa K; Hosokawa K; Maeda M
    Anal Sci; 2015; 31(7):573-6. PubMed ID: 26165275
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Sensitivity Enhancement of MicroRNA Detection Using a Power-free Microfluidic Chip.
    Kim YJ; Hosokawa K; Maeda M
    Anal Sci; 2019 Nov; 35(11):1227-1236. PubMed ID: 31327815
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Rapid and sensitive microRNA detection with laminar flow-assisted dendritic amplification on power-free microfluidic chip.
    Arata H; Komatsu H; Hosokawa K; Maeda M
    PLoS One; 2012; 7(11):e48329. PubMed ID: 23144864
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Rapid microRNA detection using power-free microfluidic chip: coaxial stacking effect enhances the sandwich hybridization.
    Arata H; Komatsu H; Han A; Hosokawa K; Maeda M
    Analyst; 2012 Jul; 137(14):3234-7. PubMed ID: 22614070
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Specificity of MicroRNA Detection on a Power-free Microfluidic Chip with Laminar Flow-assisted Dendritic Amplification.
    Hasegawa K; Negishi R; Matsumoto M; Yohda M; Hosokawa K; Maeda M
    Anal Sci; 2017; 33(2):171-177. PubMed ID: 28190836
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Biomarker Analysis on a Power-free Microfluidic Chip Driven by Degassed Poly(dimethylsiloxane).
    Hosokawa K
    Anal Sci; 2021 Mar; 37(3):399-403. PubMed ID: 33162420
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Rapid sub-attomole microRNA detection on a portable microfluidic chip.
    Arata H; Hosokawa K; Maeda M
    Anal Sci; 2014; 30(1):129-35. PubMed ID: 24420254
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Spatial distribution of laminar flow-assisted dendritic amplification.
    Hosokawa K; Maeda M
    Lab Chip; 2009 Feb; 9(3):464-8. PubMed ID: 19156297
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Laminar flow mediated continuous single-cell analysis on a novel poly(dimethylsiloxane) microfluidic chip.
    Deng B; Tian Y; Yu X; Song J; Guo F; Xiao Y; Zhang Z
    Anal Chim Acta; 2014 Apr; 820():104-11. PubMed ID: 24745743
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A blocking-free microfluidic fluorescence heterogeneous immunoassay for point-of-care diagnostics.
    Li P; Sherry AJ; Cortes JA; Anagnostopoulos C; Faghri M
    Biomed Microdevices; 2011 Jun; 13(3):475-83. PubMed ID: 21286818
    [TBL] [Abstract][Full Text] [Related]  

  • 11. OncomiR detection in circulating body fluids: a PDMS microdevice perspective.
    Potrich C; Vaghi V; Lunelli L; Pasquardini L; Santini GC; Ottone C; Quaglio M; Cocuzza M; Pirri CF; Ferracin M; Negrini M; Tiberio P; De Sanctis V; Bertorelli R; Pederzolli C
    Lab Chip; 2014 Oct; 14(20):4067-75. PubMed ID: 25178053
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Power-free microchip immunoassay of PSA in human serum for point-of-care testing.
    Okada H; Hosokawa K; Maeda M
    Anal Sci; 2011; 27(3):237-41. PubMed ID: 21415503
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Preparation of a Surface-functionalized Power-free PDMS Microchip for MicroRNA Detection Utilizing Electron Beam-induced Graft Polymerization.
    Ishihara R; Uchino Y; Hosokawa K; Maeda M; Kikuchi A
    Anal Sci; 2017; 33(2):197-202. PubMed ID: 28190840
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Continuous flow separation of particles within an asymmetric microfluidic device.
    Zhang X; Cooper JM; Monaghan PB; Haswell SJ
    Lab Chip; 2006 Apr; 6(4):561-6. PubMed ID: 16572220
    [TBL] [Abstract][Full Text] [Related]  

  • 15. NAIL: Nucleic Acid detection using Isotachophoresis and Loop-mediated isothermal amplification.
    Borysiak MD; Kimura KW; Posner JD
    Lab Chip; 2015 Apr; 15(7):1697-707. PubMed ID: 25666345
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Self-priming compartmentalization digital LAMP for point-of-care.
    Zhu Q; Gao Y; Yu B; Ren H; Qiu L; Han S; Jin W; Jin Q; Mu Y
    Lab Chip; 2012 Nov; 12(22):4755-63. PubMed ID: 22986619
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Power-free poly(dimethylsiloxane) microfluidic devices for gold nanoparticle-based DNA analysis.
    Hosokawa K; Sato K; Ichikawa N; Maeda M
    Lab Chip; 2004 Jun; 4(3):181-5. PubMed ID: 15159775
    [TBL] [Abstract][Full Text] [Related]  

  • 18. DNA detection on a power-free microchip with laminar flow-assisted dendritic amplification.
    Hosokawa K; Sato T; Sato Y; Maeda M
    Anal Sci; 2010; 26(10):1053-7. PubMed ID: 20953047
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Multiple flow profiles for two-phase flow in single microfluidic channels through site-selective channel coating.
    Logtenberg H; Lopez-Martinez MJ; Feringa BL; Browne WR; Verpoorte E
    Lab Chip; 2011 Jun; 11(12):2030-4. PubMed ID: 21409272
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Regulating oxygen levels in a microfluidic device.
    Thomas PC; Raghavan SR; Forry SP
    Anal Chem; 2011 Nov; 83(22):8821-4. PubMed ID: 21995289
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.